Automatic Osteoporosis Screening System Using Radiomics and Deep Learning from Low-Dose Chest CT Images

被引:1
|
作者
Tong, Xiaoyu [1 ]
Wang, Shigeng [1 ]
Zhang, Jingyi [1 ]
Fan, Yong [1 ]
Liu, Yijun [1 ]
Wei, Wei [1 ]
机构
[1] Dalian Med Univ, Dept Radiol, Affiliated Hosp 1, Dalian 116014, Peoples R China
来源
BIOENGINEERING-BASEL | 2024年 / 11卷 / 01期
关键词
bone mineral density; osteoporosis; deep learning; tomography; X-ray computed; radiomics;
D O I
10.3390/bioengineering11010050
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Objective: Develop two fully automatic osteoporosis screening systems using deep learning (DL) and radiomics (Rad) techniques based on low-dose chest CT (LDCT) images and evaluate their diagnostic effectiveness. Methods: In total, 434 patients who underwent LDCT and bone mineral density (BMD) examination were retrospectively enrolled and divided into the development set (n = 333) and temporal validation set (n = 101). An automatic thoracic vertebra cancellous bone (TVCB) segmentation model was developed. The Dice similarity coefficient (DSC) was used to evaluate the segmentation performance. Furthermore, the three-class Rad and DL models were developed to distinguish osteoporosis, osteopenia, and normal bone mass. The diagnostic performance of these models was evaluated using the receiver operating characteristic (ROC) curve and decision curve analysis (DCA). Results: The automatic segmentation model achieved excellent segmentation performance, with a mean DSC of 0.96 +/- 0.02 in the temporal validation set. The Rad model was used to identify osteoporosis, osteopenia, and normal BMD in the temporal validation set, with respective area under the receiver operating characteristic curve (AUC) values of 0.943, 0.801, and 0.932. The DL model achieved higher AUC values of 0.983, 0.906, and 0.969 for the same categories in the same validation set. The Delong test affirmed that both models performed similarly in BMD assessment. However, the accuracy of the DL model is 81.2%, which is better than the 73.3% accuracy of the Rad model in the temporal validation set. Additionally, DCA indicated that the DL model provided a greater net benefit compared to the Rad model across the majority of the reasonable threshold probabilities Conclusions: The automated segmentation framework we developed can accurately segment cancellous bone on low-dose chest CT images. These predictive models, which are based on deep learning and radiomics, provided comparable diagnostic performance in automatic BMD assessment. Nevertheless, it is important to highlight that the DL model demonstrates higher accuracy and precision than the Rad model.
引用
收藏
页数:15
相关论文
共 50 条
  • [31] Automated aorta segmentation in low-dose chest CT images
    Xie, Yiting
    Padgett, Jennifer
    Biancardi, Alberto M.
    Reeves, Anthony P.
    INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2014, 9 (02) : 211 - 219
  • [32] Local noise estimation in low-dose chest CT images
    Padgett, J.
    Biancardi, A. M.
    Henschke, C. I.
    Yankelevitz, D.
    Reeves, A. P.
    INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2014, 9 (02) : 221 - 229
  • [33] A Review of deep learning methods for denoising of medical low-dose CT images
    Zhang, Ju
    Gong, Weiwei
    Ye, Lieli
    Wang, Fanghong
    Shangguan, Zhibo
    Cheng, Yun
    COMPUTERS IN BIOLOGY AND MEDICINE, 2024, 171
  • [34] Local noise estimation in low-dose chest CT images
    J. Padgett
    A. M. Biancardi
    C. I. Henschke
    D. Yankelevitz
    A. P. Reeves
    International Journal of Computer Assisted Radiology and Surgery, 2014, 9 : 221 - 229
  • [35] A Review of deep learning methods for denoising of medical low-dose CT images
    Zhang, Ju
    Gong, Weiwei
    Ye, Lieli
    Wang, Fanghong
    Shangguan, Zhibo
    Cheng, Yun
    Computers in Biology and Medicine, 171
  • [36] Automated Opportunistic Osteoporosis Screening Using Low-Dose Chest CT among Individuals Undergoing Lung Cancer Screening in a Korean Population
    Kang, Woo Young
    Yang, Zepa
    Park, Heejun
    Lee, Jemyoung
    Hong, Suk-Joo
    Shim, Euddeum
    Woo, Ok Hee
    DIAGNOSTICS, 2024, 14 (16)
  • [37] Image quality improvement in low-dose chest CT with deep learning image reconstruction
    Tian, Qian
    Li, Xinyu
    Li, Jianying
    Cheng, Yannan
    Niu, Xinyi
    Zhu, Shumeng
    Xu, Wenting
    Guo, Jianxin
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2022, 23 (12):
  • [38] Automatic Deep-Learning Segmentation of Epicardial Adipose Tissue from Low-Dose Chest CT and Prognosis Impact on COVID-19
    Bartoli, Axel
    Fournel, Joris
    Ait-Yahia, Lea
    Cadour, Farah
    Tradi, Farouk
    Ghattas, Badih
    Cortaredona, Sebastien
    Million, Matthieu
    Lasbleiz, Adele
    Dutour, Anne
    Gaborit, Benedicte
    Jacquier, Alexis
    CELLS, 2022, 11 (06)
  • [39] Deep Learning-Quantified Calcium Scores for Automatic Cardiovascular Mortality Prediction at Lung Screening Low-Dose CT
    de Vos, Bob D.
    Lessmann, Nikolas
    de Jong, Pim A.
    Isgum, Ivana
    RADIOLOGY-CARDIOTHORACIC IMAGING, 2021, 3 (02):
  • [40] Automatic Segmentation of Thoracic Aorta Segments in Low-Dose Chest CT
    Noothout, Julia M. H.
    de Vos, Bob D.
    Wolterink, Jelmer M.
    Isgum, Ivana
    MEDICAL IMAGING 2018: IMAGE PROCESSING, 2018, 10574