Optimization of VO2 and VCO2 outputs for the calculation of resting metabolic rate using a portable indirect calorimeter

被引:1
|
作者
Leal-Martin, Javier [1 ,2 ,3 ]
Manas, Asier [1 ,2 ,3 ,4 ,5 ]
Alfaro-Acha, Ana [2 ,3 ,6 ]
Garcia-Garcia, Francisco Jose [2 ,3 ,6 ]
Ara, Ignacio [1 ,2 ,3 ]
机构
[1] Univ Castilla La Mancha, Fac Sports Sci, GENUD Toledo Res Grp, Toledo, Spain
[2] Inst Salud Carlos III, CIBER Fragil & Envejecimiento Saludable CIBERFES, Madrid, Spain
[3] Inst Invest Sanitaria Castilla La Mancha IDISCAM, Junta Comun Castilla La Mancha JCCM, Castilla La Mancha, Spain
[4] Ctr UCM ISCIII Human Evolut & Behav, Madrid, Spain
[5] Univ Complutense Madrid, Fac Educ, Madrid, Spain
[6] Hosp Virgen Del Valle, Complejo Hosp Univ Toledo, Geriatr Dept, Toledo, Spain
关键词
fitting equation; indirect calorimetry; metabolic device; oxygen uptake; resting energy expenditure; ENERGY-EXPENDITURE; GAS-EXCHANGE; EQUIVALENT; STABILITY; EXERCISE; VALIDITY; HEALTHY;
D O I
10.1111/sms.14425
中图分类号
G8 [体育];
学科分类号
04 ; 0403 ;
摘要
This study aimed to compare the Cosmed K5 portable indirect calorimeter, using the mixing chamber mode and face mask, with a stationary metabolic cart when measuring the resting metabolic rate (RMR) and to derive fitting equations if discrepancies are observed. Forty--three adults (18--84 years) were assessed for their RMR for two 30--min consecutive and counterbalanced periods using a Cosmed K5 and an Oxycon Pro. Differences among devices were tested using paired sample Student's t--tests, and correlation and agreement were assessed using Pearson's correlation coefficients, intraclass correlation coefficient and Bland--Altman plots. Forward stepwise multiple linear regression models were performed to develop fitting equations for estimating differences among devices when assessing oxygen uptake (VO(2)diff, mL center dot min-1) and carbon dioxide production (VCO2diff, mL center dot min-1). Furthermore, the Oxycon Pro was tested before being confirmed as a reference device. Significant differences between devices were found in most metabolic and ventilatory parameters, including the primary outcomes of VO2 and VCO2. These differences showed an overestimation of the Cosmed K-5 in all metabolic outcomes, except for Fat, when compared to the Oxycon Pro. When derived fitting equations were applied (VO2diff - 139.210 + 0.786 [weight, kg] + 1.761 [height, cm] --0.941 [Cosmed K-5 VO2, mL center dot min(-1)]; VCO(2)diff - 86.569 + 0.548 [weight, kg] + 0.915 [height, cm] --0.728 [Cosmed K-5 VCO2, mL center dot min(-1)]), differences were minimized, and agreement was maximized. This study provides fitting equations which allow the use of the Cosmed K5 for reasonably optimal RMR determinations.
引用
收藏
页码:1648 / 1660
页数:13
相关论文
共 50 条
  • [21] A WATER-SEALED INDIRECT CALORIMETER FOR MEASUREMENT OF OXYGEN-CONSUMPTION (VO2), CARBON-DIOXIDE PRODUCTION (VCO2), AND ENERGY-EXPENDITURE IN INFANTS
    DECHERT, RE
    WESLEY, JR
    SCHAFER, LE
    LAMOND, S
    NICKS, J
    CORAN, AG
    BARTLETT, RH
    JOURNAL OF PARENTERAL AND ENTERAL NUTRITION, 1988, 12 (03) : 256 - 259
  • [22] The VCO2/VO2 relationship during heavy, constant work rate exercise reflects the rate of lactic acid accumulation
    Stringer, W
    Wasserman, K
    Casaburi, R
    EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY, 1995, 72 (1-2) : 25 - 31
  • [23] Impact of periodic breathing on VO2 and VCO2:: a quantitative approach by Fourier analysis
    Francis, DP
    Davies, LC
    Willson, K
    Piepoli, M
    Seydnejad, SR
    Ponikowski, P
    Coats, AJS
    RESPIRATION PHYSIOLOGY, 1999, 118 (2-3): : 247 - 255
  • [24] Modeling. VO2 and. VCO2 with Hammerstein-Wiener Models
    Gonzalez, Alexander Artiga
    Bertschinger, Raphael
    Saupe, Dietmar
    ICSPORTS: PROCEEDINGS OF THE 4TH INTERNATIONAL CONGRESS ON SPORT SCIENCES RESEARCH AND TECHNOLOGY SUPPORT, 2016, : 134 - 140
  • [25] CONTINUOUS AND SIMULTANEOUS ONLINE MEASUREMENTS OF VO2 AND VCO2 DURING ENDOTRACHEAL ANESTHESIA
    RAMANATHAN, S
    CHALON, J
    SATYANARAYANA, T
    ARISMENDY, J
    TURNDORF, H
    ANESTHESIA AND ANALGESIA, 1982, 61 (04): : 362 - 365
  • [26] Following A Sprint Interval Session VCO2 Decreases More Rapidly Than VO2
    Olver, T. Dylan
    Hazell, Tom J.
    Hamilton, Craig D.
    Lemon, Peter W. R.
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2010, 42 (05): : 29 - 29
  • [27] BREATH-BY-BREATH VARIATIONS OF FRC - EFFECT ON VO2 AND VCO2 MEASURED AT THE MOUTH
    STOUT, RL
    WESSEL, HU
    PAUL, MH
    FEDERATION PROCEEDINGS, 1979, 38 (03) : 950 - 950
  • [28] CONTINUOUS MEASUREMENT OF VO2 AND VCO2 IN DOGS UNDER UNIFORM VENTILATION . ANALYSIS OF INSTRUMENTATION
    POCIDALO, JJ
    SIBILLE, L
    HENZEL, D
    VALLOIS, JM
    POYART, C
    JOURNAL DE PHYSIOLOGIE, 1968, S 60 : 520 - &
  • [29] Peak VO2 and VE/VCO2 slope in patients with heart failure:: A prognostic comparison
    Arena, R
    Myers, J
    Aslam, SS
    Varughese, EB
    Peberdy, MA
    AMERICAN HEART JOURNAL, 2004, 147 (02) : 354 - 360
  • [30] Peak VO2 and VE/VCO2 slope in patients with heart failure: A prognostic comparison
    Aslam, SS
    Arena, R
    Myers, J
    Varughese, E
    Peberdy, MA
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2003, 41 (06) : 216A - 216A