Comparison of OSL and TL dosimetry systems against IEC and ICRP standards

被引:1
|
作者
Zidouh, I. [1 ]
Arectout, A. [2 ]
Bellahsaouia, M. [1 ]
Elaarabi, D. [1 ]
Chamlal, H. [4 ]
Maroufi, B. [1 ]
Sadeq, Y. [4 ]
Tazi, M. [4 ]
Rodenas, J. [3 ]
Boukhal, H. [2 ]
Chakir, E. [1 ]
机构
[1] Univ Ibn Tofail Kenitra, Fac Sci, LPMS, Kenitra, Morocco
[2] Abdelmalek Essaadi Univ, Fac Sci, ERSN, Tetouan, Morocco
[3] Univ Politecn Valencia, Inst Segur Ind Radiofis & Medioambiental ISIRYM, Valencia, Spain
[4] Ctr Natl Radioprotect CNRP, Sale, Morocco
关键词
Dosimetry performance; Type testing; IEC standards; OSL dosimeter; TL dosimeter; ICRP requirements; X-RAY-SPECTRA; DEPENDENCE; ENERGY;
D O I
10.1016/j.apradiso.2023.110732
中图分类号
O61 [无机化学];
学科分类号
070301 ; 081704 ;
摘要
Personal and environmental radiation monitoring services are widely used through luminescent techniques. In this paper, we practiced performance testing on thermoluminescent and optically stimulated luminescent do-simeters by assessing their homogeneity, linearity, energy, and angular dependence tests. The IEC and ICRP requirements were used to compare the performance response of dosimeters. Based on the experimental results, we realized that both detectors comply with the international criteria. The homogeneity percentage was 8.9% and 13.7% for TL and OSL detectors, respectively. The percentage deviation of the linearity test does not exceed 10% for both dosimeters except for the TL dosimeters at low irradiation dose. For the angular dependence, deviations were less than 2% for TLDs and 5% for OSLDs. These detectors display mean values of the relative energy response of-15.29% and-6.51% for OSL and TL detectors. Generally, TL materials manifested low sensitivity to radiation dose levels. On the other hand, the OSLDs demonstrated a more pronounced under -response to energy beam qualities than TLDs. Regarding COV tests, TL and OSL dosimeters have passed the c2 test.
引用
收藏
页数:6
相关论文
共 50 条
  • [1] Dosimetry from OSL and Residual TL with TLD 400
    Stella, G.
    Cavalli, N.
    Marino, C.
    Mazzaglia, S.
    Gueli, A. M.
    [J]. JOURNAL OF INSTRUMENTATION, 2019, 14 (12):
  • [2] Characterisation of RPL and TL dosimetry systems and comparison in medical dosimetry applications
    Knezevic, Z.
    Beck, N.
    Milkovic, D.
    Miljanic, S.
    Ranogajec-Komor, M.
    [J]. RADIATION MEASUREMENTS, 2011, 46 (12) : 1582 - 1585
  • [3] Characterization of the Riso TL/OSL DA-20 reader for application in TL dosimetry
    Wrobel, D.
    Bilski, P.
    Marczewska, B.
    Mrozik, A.
    Klosowski, M.
    [J]. RADIATION MEASUREMENTS, 2015, 74 : 1 - 5
  • [4] TL and OSL dosimetric properties of Opal gemstone for gamma radiation dosimetry
    Antonio, Patricia L.
    Gronchi, Claudia C.
    Oliveira, Raquel A. P.
    Khoury, Helen J.
    Caldas, Linda V. E.
    [J]. RADIATION MEASUREMENTS, 2016, 90 : 219 - 223
  • [5] TL/OSL properties of natural schist for archaeological dating and retrospective dosimetry
    Afouxenidis, D.
    Stefanaki, E. C.
    Polymeris, G. S.
    Sakalis, A.
    Tsirliganis, N. C.
    Kitis, G.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 580 (01): : 705 - 709
  • [6] Emergency OSL/TL dosimetry with integrated circuits from mobile phones
    Sholom, S.
    McKeever, S. W. S.
    [J]. HARD X-RAY, GAMMA-RAY, AND NEUTRON DETECTOR PHYSICS XVI, 2014, 9213
  • [7] Application of TL-OSL from surface soil to retrospective dosimetry
    Fujita, H.
    [J]. RADIATION MEASUREMENTS, 2011, 46 (12) : 1870 - 1872
  • [8] Description of a portable devices developed at SCK•CEN for OSL and TL dosimetry
    Genicot, J. L.
    Moyaerts, M.
    Schroeyers, W.
    [J]. RADIATION MEASUREMENTS, 2011, 46 (12) : 1578 - 1581
  • [9] OSL and TL retrospective dosimetry with leucite glass-based dental ceramics
    Ekendahl, Daniela
    Judas, Libor
    [J]. RADIATION MEASUREMENTS, 2017, 104 : 1 - 7
  • [10] Development of cryostat integrated TL/OSL reader for its application in radiation dosimetry
    Soni, A.
    Mishra, D. R.
    Gaur, S. S.
    Uke, M.
    Sawant, P.
    Koul, D. K.
    Datta, D.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2019, 935 : 191 - 197