Development of cryostat integrated TL/OSL reader for its application in radiation dosimetry

被引:2
|
作者
Soni, A. [1 ]
Mishra, D. R. [1 ]
Gaur, S. S. [1 ]
Uke, M. [1 ]
Sawant, P. [1 ]
Koul, D. K. [1 ]
Datta, D. [1 ]
机构
[1] Bhabha Atom Res Ctr, Radiol Phys & Advisory Div, Mumbai 400085, Maharashtra, India
关键词
OSL; TA-OSL; Photo-ionization cross-section; Cryostat; OPTICALLY STIMULATED LUMINESCENCE; OSL; SYSTEM;
D O I
10.1016/j.nima.2019.04.100
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A cryostat based integrated TL/OSL reader has been designed and developed to study the temperature dependence of photoionization cross-section at various low temperatures. The system has the facility to record thermoluminescence (TL) as well as optically stimulated luminescence (OSL) at various low temperatures from -150 to 250 degrees C. It facilitates the measurement of OSL at various temperatures thus; temperature dependence of OSL at various low temperatures can be studied. A PID (Proportional-Integral-Derivative) based temperature controller has been designed and incorporated for generating and controlling user defined heating profiles for the TL measurements in the reader system. The reader system can measure the temperature of the planchet within +/- 1 degrees C precision. The optical stimulation unit consists of two high power LEDs fitted in two channels and optically focused on the sample. In the OSL operation, besides the conventional CW-OSL, LM-OSL modes a nonlinear OSL (NL-OSL) method has been incorporated in the reader system. The sensitivity of the system is found to be comparable to that of commercial Riso reader system in OSL mode. The OSL grade alpha-Al2O3:C phosphor was used to test the reader system and investigate the temperature dependence of OSL in this phosphor at low temperature regime. We report the results of OSL experiments on alpha-Al2O3:C, and of generalized numerical simulations of potential OSL behaviour with temperature. The photoionization cross-section of shallow as well as dosimetric traps has been evaluated numerically as well as experimentally. The design concept of the reader system and the results of low temperature OSL are discussed.
引用
收藏
页码:191 / 197
页数:7
相关论文
共 50 条
  • [1] Development of laser based OSL reader for its potential application in radiation dosimetry
    Soni, Anuj
    Agarwalla, S. K.
    Kakade, Nitin. R.
    Mishra, D. R.
    Sharma, S. D.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2022, 512 : 28 - 37
  • [2] Characterization of the Riso TL/OSL DA-20 reader for application in TL dosimetry
    Wrobel, D.
    Bilski, P.
    Marczewska, B.
    Mrozik, A.
    Klosowski, M.
    [J]. RADIATION MEASUREMENTS, 2015, 74 : 1 - 5
  • [3] Emergency OSL/TL dosimetry with integrated circuits from mobile phones
    Sholom, S.
    McKeever, S. W. S.
    [J]. HARD X-RAY, GAMMA-RAY, AND NEUTRON DETECTOR PHYSICS XVI, 2014, 9213
  • [4] TL and OSL dosimetric properties of Opal gemstone for gamma radiation dosimetry
    Antonio, Patricia L.
    Gronchi, Claudia C.
    Oliveira, Raquel A. P.
    Khoury, Helen J.
    Caldas, Linda V. E.
    [J]. RADIATION MEASUREMENTS, 2016, 90 : 219 - 223
  • [5] Development of Europium doped BaSO4 TL OSL dual Phosphor for Radiation Dosimetry Applications
    Patle, Anita
    Patil, R. R.
    Kulkarni, M. S.
    Bhatt, B. C.
    Moharil, S. V.
    [J]. ADVANCED MATERIALS AND RADIATION PHYSICS (AMRP-2015), 2015, 1675
  • [6] Application of TL-OSL from surface soil to retrospective dosimetry
    Fujita, H.
    [J]. RADIATION MEASUREMENTS, 2011, 46 (12) : 1870 - 1872
  • [7] Development of pulsed stimulation and Photon Timer attachments to the Riso TL/OSL reader
    Lapp, T.
    Jain, M.
    Ankjaergaard, C.
    Pirtzel, L.
    [J]. RADIATION MEASUREMENTS, 2009, 44 (5-6) : 571 - 575
  • [8] Concept development of a portable reader for personal dosimetry based on the OSL in YAP:Mn
    Ubizskii, Sergii
    Afanassyev, Denis
    Zhydachevskii, Yaroslav
    Rabyk, Vasyl
    Luchechko, Andriy
    [J]. 15TH INTERNATIONAL CONFERENCE ON ADVANCED TRENDS IN RADIOELECTRONICS, TELECOMMUNICATIONS AND COMPUTER ENGINEERING (TCSET - 2020), 2020, : 952 - 956
  • [9] OSL and TL in TLD-100 following alpha and beta irradiation: Application to mixed-field radiation dosimetry
    Oster, L.
    Horowitz, Y. S.
    Podpalov, L.
    [J]. RADIATION MEASUREMENTS, 2010, 45 (10) : 1130 - 1133
  • [10] OSL and thermally assisted OSL response in dental enamel for its possible application in retrospective dosimetry
    Anuj Soni
    D. R. Mishra
    G. S. Polymeris
    B. C. Bhatt
    M. S. Kulkarni
    [J]. Radiation and Environmental Biophysics, 2014, 53 : 763 - 774