Modification of the inverted flap technique compared to conventional internal limiting membrane peeling in complete macular hole surgery

被引:1
|
作者
Carballes, M. J. Crespo [1 ]
Sastre-Ibanez, M. [1 ]
Del Cura, M. Prieto [1 ]
De Hoz, R. [2 ]
Garcia-Saenz, M. C. [3 ]
机构
[1] Hosp Univ Infanta Leonor, Serv Oftalmol, Madrid, Spain
[2] Univ Complutense Madrid, Inst Invest Oftalmol Ramon Castroviejo, Madrid, Spain
[3] Univ Rey Juan Carlos, Hosp Univ Fdn Alcorcon, Serv Oftalmol, Madrid, Spain
关键词
Macular hole < RETINA; retinal pathology; research < RETINA; pars plana vitrectomy < VITREOUS; ENDOPHTHALMITIS; surgical instruments; special techniques < LENS; CATARACT; practice management < SOCIOECONOMICS AND EDUCATION IN MEDICINE; OPHTHALMOLOGY; OPTICAL COHERENCE TOMOGRAPHY; FIBER LAYER APPEARANCE; VISUAL OUTCOMES; ILM; EYES;
D O I
10.1177/11206721231163616
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Aim To describe the efficacy of a modification of the superior inverted flap technique, with maculorrhexis, in vitrectomy for full-thickness macular hole (MH) surgery compared to internal limiting membrane peeling (ILM). Methods Retrospective and comparative study of patients with MH. In group A, a superior ILM flap is created to cover the macular hole, and in group B conventional ILM peeling was performed. Results A total of 80 eyes were included (44 group A and 36 group B). MH closure occurred in 100% in group A and 91.67% in group B (p = 0.0869). There were more U-type closures in group A(90.91%) than in group B(58.33%), p = 0.0017. Both groups showed Best corrected visual acuity (BCVA) improvement at 3 and 6 months. At 3 months BCVA in group A was significantly better but at 6 months results were similar. Ellipsoid layer (EZ) recovery at 6 months was achieved in 81.82% patients in group A and 52.78% in B (p = 0.005), and external limiting membrane in 81.82% in group A and 69.44% in B (p = 0.1957). Conclusions The superior inverted flap maculorrhexis technique is suitable for idiopathic MH treatment, with better anatomical and non-inferior functional results than the classic ILM peeling. It achieves functional recoveries earlier, better BCVA and greater gains at 3 months compared to the classic ILM peeling. It also obtains a higher number of U-shaped closures and higher EZ restorations.
引用
收藏
页码:2275 / 2284
页数:10
相关论文
共 50 条
  • [41] Surgical results of internal limiting membrane flap inversion and internal limiting membrane peeling for macular hole
    Ota, Hiroya
    Kunikata, Hiroshi
    Aizawa, Naoko
    Nakazawa, Toru
    PLOS ONE, 2018, 13 (09):
  • [42] Is it necessary to cover the macular hole with the inverted internal limiting membrane flap in macular hole surgery? A case report
    Chung-yee Chung
    David Sai-hung Wong
    Kenneth Kai-wang Li
    BMC Ophthalmology, 15
  • [43] Is it necessary to cover the macular hole with the inverted internal limiting membrane flap in macular hole surgery? A case report
    Chung, Chung-yee
    Wong, David Sai-hung
    Li, Kenneth Kai-wang
    BMC OPHTHALMOLOGY, 2015, 15
  • [44] Comparison of the inverted inner limiting membrane flap technique and the inner limiting membrane peeling method for macular hole with retinal detachment
    Matsumura, Takehiro
    Tomomatsu, Takeshi
    Takamura, Yoshihiro
    Kobori, Akira
    Inatani, Masaru
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2016, 57 (12)
  • [45] The temporal inverted internal limiting membrane flap technique versus multilayered inverted flap technique in patients with idiopathic macular hole
    Elgouhary, Sameh M.
    Abd-elmoaty, Safaa M.
    Salama, Ahmed A.
    JOURNAL OF THE EGYPTIAN OPHTHALMOLOGICAL SOCIETY, 2025, 118 (01) : 69 - 76
  • [46] PERFLUOROCARBON LIQUID-ASSISTED INVERTED INTERNAL LIMITING MEMBRANE FLAP TECHNIQUE VERSUS INTERNAL LIMITING MEMBRANE PEELING FOR HIGHLY MYOPIC MACULAR HOLE RETINAL DETACHMENT
    Gu, Xunyi
    Hu, Zizhong
    Qian, Huiming
    Fransisca, Silvia
    Mugisha, Aime
    Wang, Jingfan
    Zhang, Zhengyu
    Zhang, Weiwei
    Ji, Jiangdong
    Liu, Qinghuai
    Xie, Ping
    RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2021, 41 (02): : 317 - 323
  • [47] Comparison of stereopsis and foveal microstructure after internal limiting membrane peeling and inverted internal limiting membrane flap techniques in patients with macular hole
    Morikawa, Shohei
    Okamoto, Fumiki
    Murakami, Tomoya
    Sugiura, Yoshimi
    Oshika, Tetsuro
    PLOS ONE, 2024, 19 (02):
  • [48] Macular changes after peeling of the internal limiting membrane in macular hole surgery
    Haritoglou, C
    Gass, CA
    Schaumberger, M
    Ehrt, O
    Gandorfer, A
    Kampik, A
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2001, 132 (03) : 363 - 368
  • [49] Macular Slippage After Macular Hole Surgery with Internal Limiting Membrane Peeling
    Nakagomi, Tomomi
    Goto, Teruhiko
    Tateno, Yasushi
    Oshiro, Tomohiro
    Iijima, Hiroyuki
    CURRENT EYE RESEARCH, 2013, 38 (12) : 1255 - 1260
  • [50] The Role of Inverted Internal Limiting Membrane Flap in Macular Hole Closure
    Shiode, Yusuke
    Morizane, Yuki
    Matoba, Ryo
    Hirano, Masayuki
    Doi, Shinichiro
    Toshima, Shinji
    Takahashi, Kosuke
    Araki, Ryoichi
    Kanzaki, Yuki
    Hosogi, Mika
    Yonezawa, Tomoko
    Yoshida, Atsushi
    Shiraga, Fumio
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2017, 58 (11) : 4847 - 4855