Evaluation of newly-developed glycated hemoglobin clinical analytic reagents and chromatography column on Tosoh HLC-723 G8 Analyzer

被引:1
|
作者
Yuan, Bo [1 ]
Yang, Wei [2 ]
Zhang, Na [1 ]
Shi, Hongyan [1 ]
Dong, Shuangpeng [1 ]
机构
[1] Tianjin Qual Control & Inspection Ctr Med Device, Dept Biochem, 5, Haitai Huake St, Tianjin 300384, Peoples R China
[2] Tianjin Adm & Market Regulat, Ctr Tianjin Med Device Evaluat & Inspection, 237, Hongqi South Rd, Tianjin 300191, Peoples R China
关键词
HPLC; HbA1c; Precision; Linearity; Carryover; HPLC; HBA1C;
D O I
10.1016/j.plabm.2023.e00338
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Objective: To evaluate the performance of newly developed glycated hemoglobin (HbA1c) clinical analytic reagents and HPLC columns, applied on Tosoh HLC-723 G8 Analyzer.Methods: Newly developed reagents and columns were used on a Tosoh HLC-723 G8 Analyzer (standard mode) system to measure both of qulity contorls and the clinical blood samples to evaluate the performances of these newly developed prodcuts including precision, accuracy, linearity, carryover, bias evaluation, correlation with commercial reagents, and stability ac-cording to CLSI recommendations.Results: The CV of intra-assay precision and inter-assay precision of quality control and clinical blood sample assays using Lirimax products were both less than 3.00%. And the REs of accuracy were less than 6.00%. Linearity: R2 = 0.9993 in the concentration range 4.77%-14.67%. Carryover: 0.05%. The Bland-Altman mean difference:-0.003583% HbA1c (CI: 0.07398:-0.08115); Passing-Bablok regression: y = 1.0022(0.9984:1.006)x-0.01097(-0.03776: 0.01582), R2 = 0.9996. Stability evaluation was also acceptable.Conclusion: The performance of newly developed products was well evaluated for HbA1c mea-surement on a TOSOH G8 Analyzer which shows excellent suitability for clinical assay.
引用
收藏
页数:8
相关论文
共 12 条
  • [1] Analytical evaluation of the Tosoh HLC-723 G8 automated HPLC analyzer for hemoglobin analysis in beta-thalassemia mode
    Merono, Francoise
    Agouti, Imane
    Bonello-Palot, Nathalie
    Paolasso, Chantal
    Levy, Nicolas
    Badens, Catherine
    CLINICAL BIOCHEMISTRY, 2011, 44 (5-6) : 441 - 443
  • [2] TOSOH HLC-723 G8检测糖化血红蛋白性能评价
    翁改志
    倪宁
    临床输血与检验, 2019, 21 (02) : 197 - 199
  • [3] Comparison of Agilent 1100 (Chromsystems) and Tosoh HLC-723 G8 HPLC systems in thalassemia screening
    Ellidag, Hamit Yasar
    Eren, Esin
    Aydin, Ozgir
    Ince, Fatma Demet Arslan
    Gok, Ibrahim
    Yilmaz, Necat
    Turkish Journal of Biochemistry-Turk Biyokimya Dergisi, 2014, 39 (04): : 544 - 548
  • [4] Analytical evaluation of the Tosoh HLC-723 G7 automated HPLC analyzer for hemoglobin A2 and F determination
    Paleari, R
    Cannata, M
    Leto, F
    Maggio, A
    Demartis, FR
    Desogus, MF
    Galanello, R
    Mosca, A
    CLINICAL BIOCHEMISTRY, 2005, 38 (02) : 159 - 165
  • [5] Interference of Thalassemias on Hemoglobin A1c Measurement by Ion-Exchange High-Performance Liquid Chromatography Method Tosoh HLC-723 G8
    Chao, Yan
    Wan, Zemin
    Wu, Xiaobin
    Qiu, Feng
    Wang, Yunxiu
    Ke, Peifeng
    Wu, Xinzhong
    Xu, Jianhua
    Zhuang, Junhua
    Huang, Xianzhang
    CLINICAL LABORATORY, 2018, 64 (7-8) : 1171 - 1175
  • [6] False increase of glycated hemoglobin due to aspirin interference in Tosoh G8 analyzer
    Gils, Charlotte
    Reinholdt, Birgitte
    Andreassen, Bjarne Damgaard
    Brandslund, Ivan
    Vinholt, Pernille Just
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2018, 56 (05) : E118 - E120
  • [7] TOSOH HLC-723 G8全自动糖化血红蛋白分析仪性能评价附视频
    陈健
    检验医学, 2013, (10) : 925 - 927
  • [8] Evaluation of the analytic performances of the new HPLC system HLC-723 G7 for the measurement of hemoglobin A1C
    Terreni, A
    Paleari, R
    Caldini, A
    Ognibene, A
    Mosca, A
    Messeri, G
    CLINICAL BIOCHEMISTRY, 2003, 36 (08) : 607 - 610
  • [9] Separation of haemoglobin HbE and HbA2 by the fully automated, high-pressure liquid chromatography Tosoh HLC-723 G7 analyzer
    Lippi, G.
    Carta, M. R.
    Salvagno, G. L.
    Bellorio, F.
    Montagnana, M.
    Soffiati, G.
    Guidi, G. C.
    INTERNATIONAL JOURNAL OF LABORATORY HEMATOLOGY, 2008, 30 (05) : 432 - 436
  • [10] Multicenter evaluation of the Tosoh G8 analyzer for determination of hemoglobin (Hb) A2 and F
    Paleari, Renata
    Ivaldi, Giovanni
    Passarello, Cristina
    Giambona, Antonino
    Mosca, Andrea
    BIOCHIMICA CLINICA, 2013, 37 (01) : 30 - 35