Treatment outcomes of applying external fixator on distal radius fractures: a randomized clinical trial to compare between two directions of force exertion in parallel to radius shaft and perpendicular to the distal radius articular surface

被引:4
|
作者
Jafari, Davood [1 ]
Birjandinejad, Ali [1 ]
Daliri, Mahla [1 ]
Emami, Kimia [1 ]
Moradi, Ali [1 ]
机构
[1] Mashhad Univ Med Sci, Orthoped Res Ctr, Mashhad, Iran
关键词
Distal radius fracture; External fixator; Distraction force; Perpendicular; Clinical outcome; Radiological outcome; UNSTABLE FRACTURES; INTRAARTICULAR FRACTURES; LOCKING PLATE; METAANALYSIS; DISTRACTION; LIGAMENTOTAXIS; CLASSIFICATION; OSTEOSYNTHESIS; QUESTIONNAIRE; REDUCTION;
D O I
10.1186/s12891-023-06358-1
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
BackgroundExternal fixation has been one of the conventional managements of unstable distal radius fracture. The main aim of this paper is to compare two methods of applying distractive force along the radius shaft versus perpendicular to the distal radius articular surface.DesignSixty patients with unstable distal radius fracture were included in present clinical trial and randomized in two groups, using block randomization method. In group A (first arm), distraction force was exerted parallel to the radius shaft. In group B (second arm), the external fixator was adjusted based on radial and palmar tilt of the mean population healthy wrist so that distraction was exerted perpendicular to the wrist articular surface.MethodsRadiological and clinical parameters were evaluated in both groups of patients pre-operatively, immediately after surgery, and 6 weeks post-operatively. We also followed up patients clinically at 12 weeks after surgery. Patient-Rated Wrist Evaluation (PRWE), Mayo wrist score, and Quick Disabilities of the Arm, Shoulder and Hand (DASH) questionnaires were used in order to assess patients' clinical and functional states.ResultsThe method used in group B resulted in better improvement of palmar tilt both immediately (P = 0.007) and at 6 weeks follow up (P = 0.013) post-operatively in comparison with patients in group A. Radius height and radial inclination were also better restored when using the proposed modified method (P = 0.001 and < 0.001, respectively). There was no difference in any of clinical results (range of motion, grip strength, PRWE, Mayo, and DASH scores) between two groups of study, 12 weeks after surgery.ConclusionApplying distractive force perpendicular to the distal radius articular surface seems to improve some radiological outcomes, probably due to better reduction maintenance, when compared with the technique of applying distraction force along distal radius shaft axis.
引用
收藏
页数:11
相关论文
共 28 条
  • [1] Treatment outcomes of applying external fixator on distal radius fractures: a randomized clinical trial to compare between two directions of force exertion in parallel to radius shaft and perpendicular to the distal radius articular surface
    Davood Jafari
    Ali Birjandinejad
    Mahla Daliri
    Kimia Emami
    Ali Moradi
    [J]. BMC Musculoskeletal Disorders, 24
  • [2] Open Reduction and Plate Fixation, External Fixator, and Conservative Treatment for Intra- articular Distal Radius Fractures
    Akdemir, Mehmet
    Kilic, Ali Ihsan
    Kurt, Cengizhan
    Capkin, Sercan
    [J]. CUREUS JOURNAL OF MEDICAL SCIENCE, 2024, 16 (01)
  • [3] Treatment of reducible unstable fractures of the distal radius: randomized clinical study comparing the locked volar plate and external fixator methods: study protocol
    Jorge Raduan Neto
    Vinicius Ynoe de Moraes
    João B Gomes dos Santos
    Flávio Faloppa
    João Carlos Belloti
    [J]. BMC Musculoskeletal Disorders, 15
  • [4] Treatment of reducible unstable fractures of the distal radius: randomized clinical study comparing the locked volar plate and external fixator methods: study protocol
    Neto, Jorge Raduan
    de Moraes, Vinicius Ynoe
    Gomes dos Santos, Joao B.
    Faloppa, Flavio
    Belloti, Joao Carlos
    [J]. BMC MUSCULOSKELETAL DISORDERS, 2014, 15
  • [5] The Value of Intraoperative 3-Dimensional Fluoroscopy in the Treatment of Distal Radius Fractures: A Randomized Clinical Trial
    Selles, C. A.
    Beerekamp, M. S. H.
    Leenhouts, P. A.
    Segers, M. J. M.
    Goslings, J. C.
    Schep, N. W. L.
    [J]. JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2020, 45 (03): : 189 - 195
  • [6] Arthroscopic debridement does not enhance surgical treatment of intra-articular distal radius fractures: a randomized controlled trial
    Selles, Caroline A.
    Mulders, Marjolein A. M.
    Colaris, Joost W.
    van Heijl, Mark
    Cleffken, Berry, I
    Schep, Niels W. L.
    [J]. JOURNAL OF HAND SURGERY-EUROPEAN VOLUME, 2020, 45 (04) : 327 - 332
  • [7] Evaluation of a novel, nonspanning external fixator for treatment of unstable extra-articular fractures of the distal radius: Biomechanical comparison with a volar locking plate
    Strauss, Eric J.
    Banerjee, Devraj
    Kummer, Frederick J.
    Tejwani, Nirmal C.
    [J]. JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2008, 64 (04): : 975 - 981
  • [8] Comparison of two surgical methods in the treatment of intra-articular distal radius fractures: Volar locking plate and K-wire augmented bridging external fixator
    Oner, Kerim
    Paksoy, Ahmet Emre
    Durusoy, Serhat
    [J]. ULUSAL TRAVMA VE ACIL CERRAHI DERGISI-TURKISH JOURNAL OF TRAUMA & EMERGENCY SURGERY, 2021, 27 (06): : 684 - 689
  • [9] Comparison of 24-Month Outcomes After Treatment for Distal Radius Fracture The WRIST Randomized Clinical Trial
    Chung, Kevin C.
    Kim, Hyungjin Myra
    Malay, Sunitha
    Shauver, Melissa J.
    [J]. JAMA NETWORK OPEN, 2021, 4 (06)
  • [10] Open Reduction Internal Fixation Versus Percutaneous Pinning With External Fixation of Distal Radius Fractures: A Prospective, Randomized Clinical Trial
    Grewal, Ruby
    MacDermid, Joy C.
    King, Graham J. W.
    Faber, Kenneth J.
    [J]. JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2011, 36A (12): : 1899 - 1906