The principles and effectiveness of X-ray scatter correction software for diagnostic X-ray imaging: A scoping review

被引:10
|
作者
Sayed, Mohammad [1 ,2 ,4 ]
Knapp, Karen M. [2 ]
Fulford, Jon [3 ]
Heales, Christine [2 ]
Alqahtani, Saeed J. [1 ]
机构
[1] Najran Univ, Coll Appl Med Sci, Diagnost Radiol Dept, Najran 61441, Saudi Arabia
[2] Univ Exeter, Coll Med & Hlth, Dept Med Imaging, St Lukes Campus,Heavitree Rd, Exeter EX1 2LU, England
[3] Univ Exeter, Med Sch, Med Sch Bldg,St Lukes Campus,Magdalen Rd, Exeter EX1 2LU, England
[4] Univ Exeter, Med Sch, Dept Med Imaging, St Lukes Campus,Heavitree Rd, Exeter EX1 2LU, Devon, England
关键词
X-ray imaging; Conventional X-ray; Radiography; Scatter correction software; Scatter reduction; Grid; Image quality; Radiation dose; BEDSIDE CHEST RADIOGRAPHY; LOW-CONTRAST DETAIL; DIGITAL RADIOGRAPHY; ANTISCATTER GRIDS; AMORPHOUS-SILICON; DOSE REDUCTION; QUALITY; RADIATION; PERFORMANCE; OPTIMIZATION;
D O I
10.1016/j.ejrad.2022.110600
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: An anti-scatter grid is often used in X-ray radiography to reduce the scattered X-rays generated from the patient. However, the presence of a grid means the patient dose subsequently increases. Recently, sever-al manufacturers have developed software that is capable of correcting for scattered X-rays without the use of a conventional grid. This scoping review aims to systematically map the research assessing scattering correction software and to identify any existing knowledge gaps.Methods: This scoping review involved conducting a systematic search in PubMed, Scopus, and Web of science to reveal studies that were relevant to the research question. Articles published between 01.01.2000 and 31.12.2021 examining X-ray scatter correction software for X-ray imaging were included. A part of the PRISMA model and PICO framework were utilised to establish eligibility criteria. A structured summary table was utilised to extract data from the selected articles.Results: In this scoping review, 20 years of literature in X-ray conventional radiography. 11 articles were included in the data synthesis. The study populations of the included studies were varied: patients, image quality phan-toms and anatomical phantoms. The clinical applications of X-ray scatter correction software were found to be limited to specific body parts (cervical spine, chest, shoulder, lumbar spine, hip and pelvis). The scatter correction software appears to be effective in terms of image quality and in reducing the radiation dose. How-ever, the conventional grid still provides a higher image quality.Conclusions: X-ray scatter correction software can be effective and provides potential benefits for some circum-stances or clinical scenarios.
引用
收藏
页数:15
相关论文
共 50 条
  • [21] Micro-Tomography of Coherent X-ray Scatter Using an X-ray Collimator and Spectral Imaging Array
    Eaker, Diane R.
    Jorgensen, Steven M.
    Cui, Congwu
    Ritman, Erik L.
    TOMOGRAPHY AND INVERSE TRANSPORT THEORY, 2011, 559 : 171 - 180
  • [22] X-RAY COMPTON SCATTER IMAGING USING A HIGH-SPEED FLYING SPOT X-RAY TUBE
    TOWE, BC
    JACOBS, AM
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1981, 28 (10) : 717 - 721
  • [23] A new x-ray scatter rejection method based on frequency division multiplexing x-ray imaging technique
    Zhang, J.
    Chang, S.
    Lu, J. P.
    Zhou, O.
    MEDICAL IMAGING 2012: PHYSICS OF MEDICAL IMAGING, 2012, 8313
  • [24] X-RAY PHOTONICS X-ray imaging goes broadband
    Roy, Sujoy
    NATURE PHOTONICS, 2011, 5 (07) : 390 - 391
  • [25] Dental X-ray for dog and cat - X-ray imaging
    Mihaljevic, Susann-Yvonne
    PRAKTISCHE TIERARZT, 2008, 89 : 10 - 14
  • [26] Realtime imaging in X-ray fluorescence and X-ray diffraction
    Sakurai, Kenji
    Mizusawa, Mari
    ACTA CRYSTALLOGRAPHICA A-FOUNDATION AND ADVANCES, 2008, 64 : C183 - C184
  • [27] X-Ray Optics for Better Diagnostic Imaging
    MacDonald, C. A.
    Gibson, W. M.
    Peppler, W. W.
    TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2002, 1 (02) : 111 - 117
  • [28] Applications of simulated x-ray spectra to x-ray imaging
    Elhila, H
    Mouze, D
    JOURNAL OF PHYSICS D-APPLIED PHYSICS, 1996, 29 (06) : 1613 - 1618
  • [29] X-ray fluorescence imaging with polycapillary X-ray optics
    Yonehara, Tasuku
    Yamaguchi, Makoto
    Tsuji, Kouichi
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2010, 65 (06) : 441 - 444
  • [30] X-RAY IMAGING Perovskites target X-ray detection
    Heiss, Wolfgang
    Brabec, Christoph
    NATURE PHOTONICS, 2016, 10 (05) : 288 - 289