Optimization design of the forced air-cooled battery thermal management system with a stepped divergence plenum

被引:14
|
作者
Suo, Yaohong [1 ,2 ]
Tang, Chengbo [1 ]
Yang, Huai [2 ]
机构
[1] Fuzhou Univ, Sch Mech Engn & Automat, Fuzhou 350108, Fujian, Peoples R China
[2] Fuzhou Univ, Sch Adv Mfg, Sch Ocean, Jinjiang 350108, Fujian, Peoples R China
基金
中国国家自然科学基金;
关键词
Air-cooled structure; Stepped divergence plenum; Slanted divergence plenum; Optimization; Thermal management; LITHIUM-ION BATTERY; FLOW CONFIGURATION; PACK; PERFORMANCE;
D O I
10.1016/j.est.2023.108904
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
In order to improve heat dissipation performance of battery pack with air-cooled structure, a novel stepped divergence plenum in Z-type air-cooled structure is proposed in a prismatic battery pack. Then the accuracy and effectiveness of computational fluid dynamics (CFD) model are verified by comparison with experimental results. Subsequently, the effects of the total height of all steps and the height of every step on the maximum temperature, temperature difference and temperature standard deviation of battery pack with air-cooled structure are explored, respectively. Finally, the stepped divergence plenum at different inlet airflow velocity is further optimized to achieve better cooling performance. Numerical results indicate that 1) For the larger total height of the steps, the stepped divergence plenum is suitable for Z-type air-cooled structure, and the stepped divergence plenum is better than the slanted one in the aspect of cooling efficiency while the latter is superior to the former for the smaller total height of the steps 2) Compared with the slanted divergence plenum, a stepped divergence plenum improves the heat dissipation performance of the battery for Z-type air-cooled structure. 3) The height of every step and inlet airflow velocity plays an important role in the cooling performance of the battery. The optimization results are h = 0.125 (i.e, Hopt = [1.39, 2.51, 2.51, 2.02, 2.02, 1.89, 1.76, 1.39, 1.51]) and 3 m/s, and the corresponding maximum temperature, temperature difference and temperature standard deviation of the battery pack are respectively reduced about 34.65 %, 77.51 % and 99.04 % in comparison with those for Z-type model. The optimization scheme proposed in this work provides a design guideline to improve the cooling performance of the air-cooled structure.
引用
收藏
页数:9
相关论文
共 50 条
  • [31] Design optimization of forced air-cooled lithium-ion battery module based on multi-vents
    Zhang, Furen
    Wang, Pengwei
    Yi, Mengfei
    [J]. JOURNAL OF ENERGY STORAGE, 2021, 40 (40):
  • [32] Performance Study of Fin Structure in Air-Cooled Thermal Management System for Column Power Battery
    Han, Peng
    Wang, Jiayun
    Zhao, Xuemin
    Liu, Jiawei
    Wang, Chen
    She, Xiaohui
    [J]. SSRN, 2024,
  • [33] Numerical study on air-cooled battery thermal management system considering the sheer altitude effect
    Li, Yonghao
    Kong, Benben
    Qiu, Chenghui
    Li, Yu
    Jiang, Yanlong
    [J]. Applied Thermal Engineering, 2025, 258
  • [34] Performance study of fin structure in air-cooled thermal management system for column power battery
    Han, Peng
    Wang, Jiayun
    Zhao, Xuemin
    Liu, Jiawei
    Wang, Chen
    She, Xiaohui
    [J]. Journal of Energy Storage, 104
  • [35] A Review on Design and Optimization of Forced Air-Cooled Cold Plate for Avionic Application
    Vedantam, Karthik
    Teja, Sabhavat Hem
    [J]. 3RD INTERNATIONAL CONFERENCE ON ADVANCEMENTS IN AEROMECHANICAL MATERIALS FOR MANUFACTURING: ICAAMM-2020, 2021, 2317
  • [36] Design and optimization of air-cooled supercapacitor thermal management system based on the corner deflectors and the inclined inlet and outlet
    Xu, Chaoying
    Li, Guofu
    Ruan, Dianbo
    [J]. ASIA-PACIFIC JOURNAL OF CHEMICAL ENGINEERING, 2024,
  • [37] A Thermal Investigation and Optimization of an Air-Cooled Lithium-Ion Battery Pack
    Peng, Xiongbin
    Cui, Xujian
    Liao, Xiangping
    Garg, Akhil
    [J]. ENERGIES, 2020, 13 (11)
  • [38] Structure optimization of parallel air-cooled battery thermal management system with U-type flow for cooling efficiency improvement
    Chen, Kai
    Song, Mengxuan
    Wei, Wei
    Wang, Shuangfeng
    [J]. ENERGY, 2018, 145 : 603 - 613
  • [39] Computational study on thermal management for an air-cooled lithium-ion battery
    Morali, Ugur
    [J]. ENERGY STORAGE, 2024, 6 (01)
  • [40] Optimal structure design and heat transfer characteristic analysis of X-type air-cooled battery thermal management system
    Luo, Lisheng
    Liu, Yicai
    Liao, Zimiao
    Zhong, Jie
    [J]. JOURNAL OF ENERGY STORAGE, 2023, 67