A Simulated Annealing optimization technique to obtain uniform dose distribution in gamma irradiators

被引:1
|
作者
Chakrabarty, Shatabdi [1 ]
Vishwakarma, R. S. [1 ]
Selvam, T. Palani [1 ,2 ]
机构
[1] Bhabha Atom Res Ctr, Radiol Phys & Advisory Div, Hlth Safety & Environm Grp, Mumbai 400094, India
[2] Homi Bhabha Natl Inst, Mumbai 400094, India
关键词
Simulated Annealing; Dose uniformity ratio; Optimization; Activity distribution; Industrial irradiator; Dose calculation;
D O I
10.1016/j.radphyschem.2023.110959
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
It is important to achieve dose uniformity in product box irradiated by gamma irradiators. To minimize lateral non-uniformity of absorbed dose, quantified as Dose Uniformity Ratio in a particular plane (DURp), activities of source pencils need to be optimized. In present study, Simulated Annealing technique is used for this purpose and the same is described for a Low-Dose 60Co Blood Irradiator. An in-house computer program is developed that calculates DURp and optimizes the activities of source pencils. The study demonstrates that only the primary component of dose is sufficient to determine DURp. In the Simulated Annealing technique, several cooling parameters are tested and the most effective cooling schedule is selected to obtain optimized activity distribution. An improvement of 22% in DURp value is observed after optimization as compared to each source pencil having the same activity. The methodology described in the paper is efficient as optimization of source activities using a trial-and-error approach will be tedious and time consuming. The optimization methodology described in the study is applicable to any irradiator geometry. However, geometry-specific dose calculation approach should be adapted.
引用
收藏
页数:7
相关论文
共 50 条
  • [41] Prostate Brachytherapy Optimization Using GPU Accelerated Simulated Annealing and Monte Carlo Dose Simulation
    Mountris, Konstantinos A.
    Bert, Julien
    Visvikis, Dimitris
    2016 IEEE NUCLEAR SCIENCE SYMPOSIUM, MEDICAL IMAGING CONFERENCE AND ROOM-TEMPERATURE SEMICONDUCTOR DETECTOR WORKSHOP (NSS/MIC/RTSD), 2016,
  • [42] Development of a technique to obtain three dimensional dose-rate distribution by Monte Carlo method
    Taniuchi, H
    Tsuboi, T
    PROCEEDINGS OF THE 1996 TOPICAL MEETING RADIATION PROTECTION & SHIELDING, VOLS 1 AND 2, 1996, 1-2 : 941 - 948
  • [43] Optimization of open-pit mine depressurization system I using simulated annealing technique
    Mohan, S.
    Sreejith, P. K.
    Pramada, S. K.
    JOURNAL OF HYDRAULIC ENGINEERING-ASCE, 2007, 133 (07): : 825 - 830
  • [44] Multiobjective Loading Pattern Optimization by Simulated Annealing Employing Discontinuous Penalty Function and Screening Technique
    Park, Tong Kyu
    Joo, Han Gyu
    Kim, Chang Hyo
    Lee, Hyun Chul
    NUCLEAR SCIENCE AND ENGINEERING, 2009, 162 (02) : 134 - 147
  • [45] Controlling an automatic voltage regulator using a novel Harris hawks and simulated annealing optimization technique
    Izci D.
    Ekinci S.
    Zeynelgil H.L.
    Advanced Control for Applications: Engineering and Industrial Systems, 2024, 6 (02):
  • [46] OPTIMIZATION OF 2-DIMENSIONAL RADOME BORESIGHT ERROR PERFORMANCE USING SIMULATED ANNEALING TECHNIQUE
    HSU, F
    CHANG, PR
    CHAN, KK
    IEEE TRANSACTIONS ON ANTENNAS AND PROPAGATION, 1993, 41 (09) : 1195 - 1203
  • [47] Fuzzy Based Project Time-Cost Optimization Using Simulated Annealing Search Technique
    Haque, Khan Md. Ariful
    Hasin, M. Ahsan Akhtar
    INTERNATIONAL JOURNAL OF INFORMATION TECHNOLOGY PROJECT MANAGEMENT, 2014, 5 (01) : 90 - 103
  • [48] Treatment planning optimization by quasi-Newton and simulated annealing methods for gamma unit treatment system
    Shu, HZ
    Yan, YL
    Bao, XD
    Fu, Y
    Luo, LM
    PHYSICS IN MEDICINE AND BIOLOGY, 1998, 43 (10): : 2795 - 2805
  • [49] Optimizing the movement of a single absorber for 1D non-uniform dose delivery by (fast) simulated annealing
    Cattaneo, GM
    Fiorino, C
    Lombardi, P
    Calandrino, R
    PHYSICS IN MEDICINE AND BIOLOGY, 1997, 42 (01): : 107 - 121
  • [50] Comparison of inverse planning simulated annealing and graphical optimization for prostate high dose-rate brachytherapy
    Sankreacha, R.
    Halina, P.
    Morton, G.
    MEDICAL PHYSICS, 2006, 33 (06) : 2081 - 2081