Performance studies of novel all-glass heat pipe evacuated collector tube integrating numerical simulation and experiment method

被引:6
|
作者
Gong, Jing-hu [1 ,2 ]
Sun, Zhi-hao [1 ]
Wang, Jun [3 ]
Lund, Peter D. [3 ,4 ]
机构
[1] Xian Univ Architecture & Technol, Sch Bldg Serv Sci & Engn, Xian 710055, Peoples R China
[2] Xian Univ Architecture & Technol, State Key Lab Green Bldg Western China, Xian 710055, Peoples R China
[3] Southeast Univ, Sch Energy & Environm, Key Lab Solar Energy Sci & Technol Jiangsu Prov, Nanjing 210096, Peoples R China
[4] Aalto Univ, Sch Sci, FI-00076 Aalto, Espoo, Finland
基金
中国国家自然科学基金;
关键词
All-glass ECT; Heat pipe; Flow field; Thermal expansion; Thermal stress; THERMAL PERFORMANCE; SOLAR COLLECTORS; SYSTEM; OPTIMIZATION; REFLECTOR; MODEL;
D O I
10.1016/j.solener.2023.02.028
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Metal heat pipe evacuated collector tube (ECT) suffer from cracks in the joint between the glass outer layer and the metal heat pipe due to the large difference in thermal expansion coefficients of glass and metal, resulting in non-industrialization. In this paper, the metal heat pipe is replaced with a glass heat pipe to form an all-glass heat pipe ECT to address the air-tight sealing problem, and a reflective film was added to the lower part of the outer tube to improve energy. According to these results, the thermal stress of 0.279 MPa is well below the bearing range of 40-120 MPa, and the maximum thermal strain of 0.175 mm/mm is also far less than the affordable value of 120 mm/mm, inducting the all-glass structure fully copes with the transient local heating changes. The optical efficiency is increased by 0.17 % by the addition of the reflective film, and yielding an energy output of 87 W and a maximum volume fraction of 4.8 % for liquid-water in the quasi-thermal equilibrium state. At the same time, the evaporation operating speed of the vapor can be increased by improving the solar radiation flux density and reducing thermal losses, and optimizing the multi-level and cross-scale vapor vortices can also improve the convective heat transfer rate, so they are future directions for development. However, there are the limitations of decreasing the thermal conductivity and increases the resistance due to the heat pipe conversion from metal to glass.
引用
收藏
页码:491 / 500
页数:10
相关论文
共 50 条
  • [31] Influences of tracking and installation errors on the optical performance of a parabolic trough collector with heat pipe evacuated tube
    Zhang, Weiwei
    Duan, Linzuo
    Wang, Jiabin
    Ba, Xuyang
    Zhang, Zijing
    Tian, Rui
    Sustainable Energy Technologies and Assessments, 2022, 50
  • [32] Experimental analysis of thermal performance according to heat pipe working fluids for evacuated tube solar collector
    Joo, Hong-Jin
    Kwak, Hee-Youl
    HEAT AND MASS TRANSFER, 2017, 53 (11) : 3267 - 3275
  • [33] Numerical Investigation of A Novel Single-Pass All-Glass Receiver for Parabolic Trough Collector
    Peng, Yao
    Ren, Tianqi
    Xia, Bo
    Wang, Yinfeng
    Zhu, Yuezhao
    ENERGY SOURCES PART A-RECOVERY UTILIZATION AND ENVIRONMENTAL EFFECTS, 2021, 43 (15) : 1838 - 1852
  • [34] Performance evaluation of all-glass evacuated tube solar water heater with twist tape inserts using CFD
    Yao, Keguang
    Li, Tong
    Tao, Hanzhong
    Wei, Jiajie
    Feng, Ke
    INTERNATIONAL CONFERENCE ON SOLAR HEATING AND COOLING FOR BUILDINGS AND INDUSTRY, SHC 2014, 2015, 70 : 332 - 339
  • [35] High temperature collecting performance of a new all-glass evacuated tubular solar air heater with U-shaped tube heat exchanger
    Wang, Pin-Yang
    Guan, Hong-Yang
    Liu, Zhen-Hua
    Wang, Guo-San
    Zhao, Feng
    Xiao, Hong-Sheng
    ENERGY CONVERSION AND MANAGEMENT, 2014, 77 : 315 - 323
  • [36] Performance analysis of a novel sun-tracking CPC heat pipe evacuated tubular collector
    Wang, Yinfeng
    Zhu, Yuezhao
    Chen, Haijun
    Zhang, Xin
    Yang, Li
    Liao, Chuanhua
    APPLIED THERMAL ENGINEERING, 2015, 87 : 381 - 388
  • [37] Augmentation of thermal efficiency of the glass evacuated solar tube collector with coaxial heat pipe with different refrigerants and filling ratio
    Kabeel, A. E.
    Dawood, Mohamed M. Khairat
    Shehata, Ali I.
    ENERGY CONVERSION AND MANAGEMENT, 2017, 138 : 286 - 298
  • [38] Experimental performance evaluation of a novel designed phase change material integrated manifold heat pipe evacuated tube solar collector system
    Chopra, K.
    Tyagi, V. V.
    Pathak, Atin K.
    Pandey, A. K.
    Sari, Ahmet
    ENERGY CONVERSION AND MANAGEMENT, 2019, 198
  • [39] Experimental study on the natural convective heat transfer in a horizontally disposed all glass evacuated solar collector tube
    Wang, Li-ting
    Lu, wei-de
    Huo, Zhi-chen
    Taiyangneng Xuebao/Acta Energiae Solaris Sinica, 1989, 10 (02): : 177 - 184
  • [40] Theoretical and experimental analysis of thermal performance of a solar water heating system with evacuated tube heat pipe collector
    Daghigh, Roonak
    Shafieian, Abdellah
    APPLIED THERMAL ENGINEERING, 2016, 103 : 1219 - 1227