Comparison of Neuroform Atlas Stent-Assisted Coiling and Coiling Alone in Ruptured Intracranial Aneurysms: A Propensity Score Matching Analysis

被引:8
|
作者
Yi, Ho Jun [1 ,2 ,3 ]
Shin, Dong-Seong [1 ,4 ]
Kim, Bum-Tae [1 ]
Lee, Dong Hoon [2 ]
Sung, Jae Hoon [2 ]
机构
[1] Soon chunhyang Univ, Dept Neurosurg, Bucheon Hosp, Bucheon, South Korea
[2] Catholic Univ Korea, St Vincents Hosp, Coll Med, Dept Neurosurg, Seoul, South Korea
[3] Hallym Univ, Hangang Sacred Heart Hosp, Dept Neurosurg, Seoul, South Korea
[4] Soonchunhyang Univ, Dept Neurosurg, Bucheon Hosp, 170,Jomaru Ro, Bucheon 14584, Gyeonggi, South Korea
基金
新加坡国家研究基金会;
关键词
Aneurysm; Coil; Stent; Subarachnoid hemorrhage; ENDOVASCULAR COILING; CEREBRAL ANEURYSMS; EFFICACY; SAFETY;
D O I
10.1227/neu.0000000000002254
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BACKGROUND:Although Neuroform Atlas stent is commonly used in stent-assisted coiling (SAC) to treat ruptured intracranial aneurysms (RIA), its safety and efficacy remain controversial.OBJECTIVE:To assess the safety and efficacy of SAC using Neuroform Atlas for treating RIA compared with coiling alone by performing a propensity score matching analysis.METHODS:RIA treated with coiling alone and SAC between January 2017 and May 2021 were retrospectively reviewed. Demographics, periprocedural complication rates, angiographic outcomes, and clinical outcomes of the SAC using Neuroform Atlas group and the coiling-alone group were analyzed with 1:1 propensity score matching.RESULTS:A total of 375 aneurysms were enrolled, and 274 (63.1%) aneurysms were treated with coiling alone. In total, 101 (26.9%) aneurysms were treated with SAC, and Neuroform Atlas stent was used in 71 aneurysms. In propensity score matching, the SAC using Neuroform Atlas group showed higher incidence of complete occlusion (69.0% vs 56.3%, P = .029), lower rate of recanalization (11.3% vs 25.4%, P = .011), and lesser need for retreatment (7.0% vs 16.9%, P = .016) compared with the coiling-alone group. However, there were no significant differences in periprocedural complications such as intraprocedural thrombosis or postprocedural cerebral infarct between the 2 groups.CONCLUSION:The use of Neuroform Atlas is safe and effective for SAC in RIA with comparable procedure-related complication rates but better angiographic outcome in comparison with coiling alone.
引用
收藏
页码:607 / 614
页数:8
相关论文
共 50 条
  • [41] Clinical and angiographic outcomes of stent-assisted coiling of paraclinoid aneurysms: Comparison of LVIS and Neuroform stents
    Di, Ruo-yu
    Ge, Liang
    Lu, Gang
    Huang, Lei
    Jiang, Ye-qing
    Wan, Hai-lin
    Zhang, Jun
    Geng, Dao-ying
    Zhang, Xiao-long
    JOURNAL OF CLINICAL NEUROSCIENCE, 2021, 83 : 1 - 7
  • [42] Comparison between Solitaire™ AB and Enterprise stent-assisted coiling for intracranial aneurysms
    Ye, Hua-Wei
    Liu, Ya-Qi
    Wang, Qiu-Jing
    Zheng, Tao
    Cui, Xu-Bo
    Gao, Yu-Yuan
    Lai, Ling-Feng
    Zhang, Xin
    Li, Xi-Feng
    Su, Shi-Xing
    He, Xu-Ying
    Duan, Chuan-Zhi
    EXPERIMENTAL AND THERAPEUTIC MEDICINE, 2015, 10 (01) : 145 - 153
  • [43] Threshold for Packing Density in Stent-Assisted Coiling of Intracranial Aneurysms
    Chalouhi, Nohra
    Dumont, Aaron S.
    Tjoumakaris, Stavropoula I.
    Gonzalez, Fernando
    Starke, Robert M.
    Dalyai, Richard
    El Moursi, Sedeek
    Rosenwasser, Robert H.
    Hasan, David M.
    Jabbour, Pascal
    NEUROSURGERY, 2012, 71 (02) : E553 - E553
  • [44] Y-Stent-Assisted Coiling of Wide-Necked Intracranial Aneurysms With the Neuroform Atlas Stent System
    Jadhav, Ashutosh P.
    Desai, Shashvat M.
    Jovin, Tudor G.
    Hanel, Ricardo A.
    Sauvageau, Eric A.
    Aghaebrahim, Amin
    Lin, Eugene
    Khaldi, Ahmad
    Gupta, Rishi G.
    Johnson, Andrew K.
    Frei, Donald
    Loy, David
    Malek, Adel
    Toth, Gabor
    Siddiqui, Adnan
    Reavey-Cantwell, John
    Thomas, Ajith
    Hetts, Steven W.
    Zaidat, Osama O.
    Jankowitz, Brian T.
    STROKE-VASCULAR AND INTERVENTIONAL NEUROLOGY, 2023, 3 (01):
  • [45] A single-center comparative study with large sample size on stent-assisted coiling versus coiling alone for the ruptured anterior communicating artery aneurysms: Analysis of safety, efficacy, and prognosis based on propensity score matching
    Shang, Wei
    Chang, Xiaoting
    Xu, Yousong
    Dong, Bin
    INTERVENTIONAL NEURORADIOLOGY, 2025, 31 (01) : 71 - 79
  • [46] RETRACTION: Retraction Note: Comment on "Comparison of LVIS and enterprise stent-assisted coiling embolization for ruptured intracranial aneurysms: a propensity score-matched cohort study"
    Marunganathan, Vanitha
    Guru, Ajay
    NEUROSURGICAL REVIEW, 2025, 48 (01)
  • [47] The safety and efficacy of a low dose of tirofiban for early complications during and after stent-assisted coiling of ruptured intracranial aneurysms: A propensity matching study
    Shen, Guangchen
    Jia, Zhenyu
    Zhao, Linbo
    Lu, Guangdong
    Liu, Sheng
    Shi, Haibin
    CLINICAL NEUROLOGY AND NEUROSURGERY, 2022, 214
  • [48] Stent-assisted coiling for the treatment of ruptured micro-intracranial wide-necked aneurysms
    Yu, Ming
    Liu, Fangjiu
    Jiang, Shijie
    Nie, Bengang
    INTERVENTIONAL NEURORADIOLOGY, 2015, 21 (01) : 40 - 43
  • [49] Safety and efficacy of stent-assisted coiling ruptured intracranial aneurysms: A single-center experience
    Zhang, Deng-Xiang
    Luo, Chao-Bao
    Lee, Chien-Hui
    TZU CHI MEDICAL JOURNAL, 2025, 37 (02): : 189 - 197
  • [50] The safety and efficacy of low-dosage tirofiban for stent-assisted coiling of ruptured intracranial aneurysms
    Yan, Yazhou
    He, Xiaowu
    Fang, Yibin
    Xu, Yi
    Hong, Bo
    Liu, Jianmin
    Huang, Qinghai
    NEUROSURGICAL REVIEW, 2021, 44 (04) : 2211 - 2218