Combination of automated sample preparation and micro-flow LC-MS for high-throughput plasma proteomics

被引:6
|
作者
Ye, Xueting [1 ,2 ,3 ,4 ]
Cui, Xiaozhen [3 ,4 ]
Zhang, Luobin [1 ]
Wu, Qiong [3 ,4 ]
Sui, Xintong [3 ,4 ]
He, An [3 ,4 ]
Zhang, Xinyou [1 ]
Xu, Ruilian [1 ]
Tian, Ruijun [3 ,4 ]
机构
[1] Southern Univ Sci & Technol, Jinan Univ, Clin Med Coll 2, Shenzhen Peoples Hosp,Affiliated Hosp 1, Shenzhen 518020, Peoples R China
[2] Jinan Univ, Affiliated Hosp 1, Guangzhou 510632, Peoples R China
[3] Southern Univ Sci & Technol, Sch Sci, Dept Chem, Shenzhen 518055, Peoples R China
[4] Southern Univ Sci & Technol, Res Ctr Chem Biol & Om Anal, Shenzhen 518055, Peoples R China
基金
中国国家自然科学基金;
关键词
Plasma proteome profiling; Automated samples preparation; Micro-flow LC-MS; High throughput; COLORECTAL-CANCER; PEPTIDE IDENTIFICATION; DEPLETION; PROTEINS;
D O I
10.1186/s12014-022-09390-w
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Background Non-invasive detection of blood-based markers is a critical clinical need. Plasma has become the main sample type for clinical proteomics research because it is easy to obtain and contains measurable protein biomarkers that can reveal disease-related physiological and pathological changes. Many efforts have been made to improve the depth of its identification, while there is an increasing need to improve the throughput and reproducibility of plasma proteomics analysis in order to adapt to the clinical large-scale sample analysis.Methods We have developed and optimized a robust plasma analysis workflow that combines an automated sample preparation platform with a micro-flow LC-MS-based detection method. The stability and reproducibility of the workflow were systematically evaluated and the workflow was applied to a proof-of-concept plasma proteome study of 30 colon cancer patients from three age groups.Results This workflow can analyze dozens of samples simultaneously with high reproducibility. Without protein depletion and prefractionation, more than 300 protein groups can be identified in a single analysis with micro-flow LC-MS system on a Orbitrap Exploris 240 mass spectrometer, including quantification of 35 FDA approved disease markers. The quantitative precision of the entire workflow was acceptable with median CV of 9%. The preliminary proteomic analysis of colon cancer plasma from different age groups could be well separated with identification of potential colon cancer-related biomarkers.Conclusions This workflow is suitable for the analysis of large-scale clinical plasma samples with its simple and time-saving operation, and the results demonstrate the feasibility of discovering significantly changed plasma proteins and distinguishing different patient groups.
引用
收藏
页数:10
相关论文
共 50 条
  • [31] The Optimized Workflow for Sample Preparation in LC-MS/MS-Based Urine Proteomics
    Saito, Suguru
    Hirao, Yoshitoshi
    Quadery, Ali F.
    Xu, Bo
    Elguoshy, Amr
    Fujinaka, Hidehiko
    Koma, Shohei
    Yamamoto, Keiko
    Yamamoto, Tadashi
    METHODS AND PROTOCOLS, 2019, 2 (02) : 1 - 13
  • [32] Automated processing of sample preparation for homocysteine analysis using LC-MS/MS
    Jun, S.
    Lee, K.
    Song, J.
    CLINICA CHIMICA ACTA, 2022, 530 : S288 - S288
  • [33] Derivatization-based High-throughput Bioanalysis by LC-MS
    Toyo'oka, Toshimasa
    ANALYTICAL SCIENCES, 2017, 33 (05) : 555 - 564
  • [34] Dual LC-MS Platform for High-Throughput Proteome Analysis
    Orton, Dennis J.
    Wall, Mark J.
    Doucette, Alan A.
    JOURNAL OF PROTEOME RESEARCH, 2013, 12 (12) : 5963 - 5970
  • [35] High-throughput LC-MS quantitation of cell culture metabolites
    Sun, Zhiyuan
    Ji, Qinqin
    Evans, Adam R.
    Lewis, Michael J.
    Mo, Jingjie
    Hu, Ping
    BIOLOGICALS, 2019, 61 : 44 - 51
  • [36] A high-throughput processing service for retention time alignment of complex proteomics and metabolomics LC-MS data
    Ahmad, Isthiaq
    Suits, Frank
    Hoekman, Berend
    Swertz, Morris A.
    Byelas, Heorhiy
    Dijkstra, Martijn
    Hooft, Rob
    Katsubo, Dmitry
    van Breukelen, Bas
    Bischoff, Rainer
    Horvatovich, Peter
    BIOINFORMATICS, 2011, 27 (08) : 1176 - 1178
  • [37] Derivatization-based High-throughput Bioanalysis by LC-MS
    Toshimasa Toyo’Oka
    Analytical Sciences, 2017, 33 : 555 - 564
  • [38] A high-throughput LC-MS/MS method for simultaneous determination of isoniazid, ethambutol and pyrazinamide in human plasma
    Prso, Kristian
    Zidekova, Nela
    Porvaznik, Igor
    Solovic, Ivan
    Mokry, Juraj
    Kertys, Martin
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2023, 37 (02)
  • [39] High-throughput toxicological analysis of Methamphetamine, MDA and MDMA from human plasma by LC-MS/MS
    Vlase, Laurian
    Popa, Daniela-Saveta
    Loghin, Felicia
    Leucuta, Sorin E.
    ROMANIAN JOURNAL OF LEGAL MEDICINE, 2009, 17 (03): : 213 - 220
  • [40] Fast and high-throughput LC-MS characterization, and peptide mapping of engineered AAV capsids using LC-MS/MS
    Lam, Anh K.
    Zhang, Junping
    Frabutt, Dylan
    Mulcrone, Patrick L.
    Li, Lei
    Zeng, Lifan
    Herzog, Roland W.
    Xiao, Weidong
    MOLECULAR THERAPY-METHODS & CLINICAL DEVELOPMENT, 2022, 27 : 185 - 194