Numerical Simulation on Smoke Temperature Distribution in a Large Indoor Pedestrian Street Fire

被引:5
|
作者
Lin, Weidong [1 ]
Liu, Qiyu [2 ]
Zhang, Meihong [3 ]
Cai, Bihe [4 ]
Wang, Hui [5 ]
Chen, Jian [6 ]
Zhou, Yang [2 ]
机构
[1] Fujian Prov Inst Architectural Design & Research C, Fuzhou 350001, Peoples R China
[2] Cent South Univ, Sch Civil Engn, Changsha 410075, Peoples R China
[3] Xiamen Fire Rescue Detachment, Xiamen 361013, Peoples R China
[4] YanGuo Technol Co Ltd, Xiamen 361001, Peoples R China
[5] Fujian Construct Engn Grp Co Ltd, Fuzhou 350001, Peoples R China
[6] China Acad Bldg Res, Beijing 100013, Peoples R China
来源
FIRE-SWITZERLAND | 2023年 / 6卷 / 03期
关键词
safety engineering; numerical simulation; large indoor pedestrian street fire; smoke spread; temperature distribution; smoke exhaust;
D O I
10.3390/fire6030115
中图分类号
Q14 [生态学(生物生态学)];
学科分类号
071012 ; 0713 ;
摘要
In order to study the characteristics of fire smoke spread and temperature distribution of a large indoor pedestrian street under different heat release rates and smoke exhaust modes, this paper focuses on the analysis of fire smoke spread, visibility, smoke temperature distribution and variation curves in an atrium. This paper uses a numerical simulation method to conduct research. PyroSim fire simulation software is used to calculate this project, which is based on a full-scale experimental design scheme. The numerical simulation results show that under the conditions of higher heat release rate, the smoke spread rate is greater than that under the conditions of lower heat release rate. Furthermore, the average temperature of smoke in the atrium is also greater, up to about 400 degrees C. The conditions of a higher heat release rate also show the characteristics of faster generation, faster spread and a larger volume of smoke. When the smoke exhaust system is turned on, the thickness of the smoke layer and the smoke temperature decrease. There then comes a situation where the stabile section of the fire ends in advance. The simulation results of vertical temperature distribution in an atrium can fit the modified McCaffrey plume model in any case. Under all cases, the smoke temperature reaches the maximum directly above the fire source. The horizontal dimensionless smoke temperature rises under the atrium roof, and decreases exponentially with the dimensionless distance from the fire source. The greater the heat release rate of fire source is, the smaller the attenuation coefficient is, with a more than 50% change. When the smoke exhaust system is turned on, the smoke flow accelerates and the smoke is cooled rapidly. Thus, the attenuation coefficient increases. Additionally, the effect of mechanical smoke exhaust is better than natural smoke exhaust, because mechanical smoke exhaust makes air flow and heat exchange more intense. The variation amplitudes of the attenuation coefficient under natural smoke exhaust and mechanical smoke exhaust are 13% and 22%, respectively.
引用
收藏
页数:18
相关论文
共 50 条
  • [31] Experimental and numerical studies on longitudinal smoke temperature distribution upstream and downstream from the fire in a road tunnel
    Hu, L. H.
    Huo, R.
    Wang, H. B.
    Yang, R. X.
    JOURNAL OF FIRE SCIENCES, 2007, 25 (01) : 23 - 43
  • [32] Two typical phenomena from the numerical simulation of fire and smoke transport in a gymnasium fire
    Chen Jianguo
    Chen Haixin
    Fu Song
    CHINESE SCIENCE BULLETIN, 2006, 51 (12): : 1521 - 1525
  • [34] Numerical temperature field simulation of fire scenarios
    Mangerig, I.
    Beucher, S.
    Giese, Y.
    BAULICHER UND GEBAUDETECHNISCHER BRANDSCHUTZ, 2009, 2062 : 107 - 122
  • [35] Experimental study and numerical simulation on the temperature distribution of oil-pool-fire burning
    Fu, Su-Hong
    Cao, Guang-Jun
    Li, Ji-Feng
    Zhang, Dong-Sheng
    Li, Lei
    Kung Cheng Je Wu Li Hsueh Pao/Journal of Engineering Thermophysics, 2010, 31 (08): : 1411 - 1414
  • [36] Simulation of temperature and smoke distribution of a tunnel fire based on modifications of multi-layer zone model
    Chen Xiaojun
    TUNNELLING AND UNDERGROUND SPACE TECHNOLOGY, 2008, 23 (01) : 75 - 79
  • [37] Inclination Effects on Temperature Distribution of Fire Smoke for Highway Tunnel
    Jianwei Cheng
    Zui Wang
    Fangyuan Liu
    Chang Qi
    Iranian Journal of Science and Technology, Transactions of Civil Engineering, 2021, 45 : 2817 - 2830
  • [38] Inclination Effects on Temperature Distribution of Fire Smoke for Highway Tunnel
    Cheng, Jianwei
    Wang, Zui
    Liu, Fangyuan
    Qi, Chang
    IRANIAN JOURNAL OF SCIENCE AND TECHNOLOGY-TRANSACTIONS OF CIVIL ENGINEERING, 2021, 45 (04) : 2817 - 2830
  • [39] Large Eddy Simulation of wind flow impact on fire-induced indoor and outdoor air pollution in an idealized street canyon
    Pesic, Dusica J.
    Zigar, Darko N.
    Anghel, Ion
    Glisovic, Srdjan M.
    JOURNAL OF WIND ENGINEERING AND INDUSTRIAL AERODYNAMICS, 2016, 155 : 89 - 99
  • [40] Numerical Simulation of Fire-Smoke Diffusion Caused by Vehicles in a Tunnel
    Lei, Li
    Chen, Wukai
    Li, Huiling
    Shi, Shuai