Hard X-ray full-field nanoimaging using a direct photon-counting detector

被引:5
|
作者
Flenner, Silja [1 ]
Hagemann, Johannes [2 ]
Wittwer, Felix [2 ,4 ]
Longo, Elena [1 ,5 ]
Kubec, Adam [3 ,6 ]
Rothkirch, Andre [2 ]
David, Christian [3 ]
Mueller, Martin [1 ]
Greving, Imke [1 ]
机构
[1] Helmholtz Zentrum Hereon, Max Planck Str 1, D-21502 Geesthacht, Germany
[2] DESY, Ctr Xray & Nano Sci CXNS, Notkestr 85, D-22607 Hamburg, Germany
[3] Paul Scherrer Inst, Forsch Str 111, CH-5232 Villigen, Switzerland
[4] Lawrence Berkeley Natl Lab, NERSC, Berkeley, CA 94720 USA
[5] Elettra Sincrotrone Trieste SCpA, I-34149 Trieste, Italy
[6] XRnanotech GmbH, Forsch Str 111, CH-5232 Villigen, Switzerland
关键词
nanotomography; full-field X-ray microscopy; near-field holography; near-field ptychography; Zernike phase contrast; singlephoton-counting detector; phase contrast; PHASE-CONTRAST; RESOLUTION; TOMOGRAPHY; HOLOGRAPHY; RETRIEVAL; NOISE;
D O I
10.1107/S1600577522012103
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Full-field X-ray nanoimaging is a widely used tool in a broad range of scientific areas. In particular, for low-absorbing biological or medical samples, phase contrast methods have to be considered. Three well established phase contrast methods at the nanoscale are transmission X-ray microscopy with Zernike phase contrast, near-field holography and near-field ptychography. The high spatial resolution, however, often comes with the drawback of a lower signal-to-noise ratio and significantly longer scan times, compared with microimaging. In order to tackle these challenges a single-photon-counting detector has been implemented at the nanoimaging endstation of the beamline P05 at PETRA III (DESY, Hamburg) operated by Helmholtz-Zentrum Hereon. Thanks to the long sample-to-detector distance available, spatial resolutions of below 100 nm were reached in all three presented nanoimaging techniques. This work shows that a single-photon-counting detector in combination with a long sample-todetector distance allows one to increase the time resolution for in situ nanoimaging, while keeping a high signal-to-noise level.
引用
收藏
页码:390 / 399
页数:10
相关论文
共 50 条
  • [11] Applications of Hard X-ray Full-Field Transmission X-ray Microscopy at SSRL
    Liu, Y.
    Andrews, J. C.
    Meirer, F.
    Mehta, A.
    Carrasco Gil, S.
    Sciau, P.
    Mester, Z.
    Pianetta, P.
    10TH INTERNATIONAL CONFERENCE ON X-RAY MICROSCOPY, 2011, 1365 : 357 - 360
  • [12] Photon-counting x-ray detectors for CT
    Danielsson, Mats
    Persson, Mats
    Sjolin, Martin
    PHYSICS IN MEDICINE AND BIOLOGY, 2021, 66 (03):
  • [13] X-ray spectroscopy with a photon-counting SiPM-based scintillation detector
    Ceravolo, S.
    Gargiulo, R.
    Paesani, D.
    Russo, A.
    Sarra, I.
    JOURNAL OF INSTRUMENTATION, 2023, 18 (09)
  • [14] Spectral X-ray phase contrast imaging with a CdTe photon-counting detector
    Navarrete, Carlos
    Procz, Simon
    Schuetz, Michael Kilian
    Roque, Gerardo
    Fey, Julian
    Avila, Carlos
    Olivo, Alessandro
    Fiederle, Michael
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2020, 971 (971):
  • [15] Biomedical x-ray imaging with a GaAs photon-counting detector: A comparative study
    Scholz, J.
    Birnbacher, L.
    Petrich, C.
    Riedel, M.
    Heck, L.
    Gkoumas, S.
    Sellerer, T.
    Achterhold, K.
    Herzen, J.
    APL PHOTONICS, 2020, 5 (10)
  • [16] A New High-speed, Photon-counting X-ray Area Detector
    Durst, Roger
    Becker, Bruce
    Diawara, Yacouba
    Khazins, David
    Medved, Sergei
    Sedov, Vladisov
    Smith, Kingsley
    Thorson, Tim
    Wachter, Greg
    ACTA CRYSTALLOGRAPHICA A-FOUNDATION AND ADVANCES, 2005, 61 : C39 - C39
  • [17] The effects of photon flux on energy spectra and imaging characteristics in a photon-counting x-ray detector
    Cho, H-M
    Kim, H-J
    Choi, Y-N
    Lee, S-W
    Ryu, H-J
    Lee, Y-J
    PHYSICS IN MEDICINE AND BIOLOGY, 2013, 58 (14): : 4865 - 4879
  • [18] Comparison of Radiologist Performance with Photon-Counting Full-Field Digital Mammography to Conventional Full-Field Digital Mammography
    Cole, Elodia B.
    Toledano, Alicia Y.
    Lundqvist, Mats
    Pisano, Etta D.
    ACADEMIC RADIOLOGY, 2012, 19 (08) : 916 - 922
  • [19] Development of hard X-ray dark-field microscope using full-field optics
    Graduate School of Material Science, University of Hyogo, Kamigori, Hyogo
    678-1297, Japan
    不详
    980-8577, Japan
    Jpn. J. Appl. Phys., 1600, 10
  • [20] Development of hard X-ray dark-field microscope using full-field optics
    Takano, Hidekazu
    Azuma, Hiroaki
    Shimomura, Sho
    Tsuji, Takuya
    Tsusaka, Yoshiyuki
    Kagoshima, Yasushi
    JAPANESE JOURNAL OF APPLIED PHYSICS, 2016, 55 (10)