The Use of the Implantable Doppler Probe as a Blood Flow Monitoring Device in Clinical Settings: A Narrative Review of the Evidence

被引:7
|
作者
Malik, Muhammad Shahzar [1 ]
Akoh, Jacob A. [1 ]
Houlberg, Kris [1 ]
机构
[1] Univ Hosp Plymouth NHS Trust, Southwest Transplant Ctr, Plymouth, Devon, England
关键词
Free flap; Graft; Transplantation; Vascular flow monitoring; COOK-SWARTZ-DOPPLER; BURIED FREE FLAPS; BYPASS; RECONSTRUCTION; VELOCITY; SYSTEM; HEAD;
D O I
10.6002/ect.2022.0349
中图分类号
R3 [基础医学]; R4 [临床医学];
学科分类号
1001 ; 1002 ; 100602 ;
摘要
Objectives: In the past decade, the implantable Doppler probe has been studied widely as a blood flow-monitoring device in reconstructive and transplant surgical specialities. Its utility as an effective postoperative monitoring technique is still debatable, with no clear guidelines in clinical practice. Here, we mapped the current evidence on the usefulness of the implantable Doppler probe as a blood flow-monitoring device. The objective was to present an up-to-date assessment of the benefits and limitations of using implantable Doppler probes in clinical and experimental clinical settings. Materials and Methods: We conducted a literature search using the Cochrane Library and Healthcare Databases Advanced Search and using implantable Doppler probe, transplant, graft, and flap as key words. The search yielded 184 studies, with 73 studies included after exclusions. We evaluated, synthesized, and summarized the evidence from the studies in tabular form. Results: There is clinical equipoise regarding the effectiveness of implantable Doppler probe as a flow sensing technique. The main reason is the lack of information and gaps in the evidence regarding the benefits and limitations of using implantable Doppler probes in clinical practice. Conclusions: The implantable Doppler probe has the potential to be used as an adjunct postoperative blood flow-monitoring device. However, keeping in view of technical limitations, its signals should be interpreted alongside traditional clinical assessment techniques to determine the patency of microvascular anastomosis. Although evidence in this review will inform clinical practice in transplant and reconstructive surgical specialties, a prospective randomized controlled study with a larger patient cohort is required to evaluate the effectiveness of this probe in clinical settings.
引用
收藏
页码:83 / 92
页数:10
相关论文
共 50 条
  • [41] The use of color Doppler EUS in monitoring effects of vasoactive agents on azygos blood flow in portal hypertension.
    Sung, JY
    Lee, YT
    Chung, SCS
    GASTROINTESTINAL ENDOSCOPY, 1998, 47 (04) : AB155 - AB155
  • [42] ONE WEEK OF MONITORING OF PORTAL AND HEPATIC ARTERIAL BLOOD-FLOW AFTER LIVER-TRANSPLANTATION USING IMPLANTABLE PULSED DOPPLER MICROPROBES
    HOUSSIN, D
    FRATACCI, M
    DUPUY, P
    VIGOUROUX, C
    GATECEL, C
    PAYEN, D
    CHAPUIS, Y
    TRANSPLANTATION PROCEEDINGS, 1989, 21 (01) : 2277 - 2278
  • [43] Use and impact of clinical pathways across various healthcare settings: A protocol for an umbrella review of global evidence
    Chandra, Rishita
    Unwin, Maria
    Tran, Viet
    Neil, Amanda
    JOURNAL OF EVALUATION IN CLINICAL PRACTICE, 2024,
  • [44] SIMULTANEOUS MEASUREMENT OF VELOCITY, DIAMETER, FLOW AND PRESSURE IN THE ASCENDING AORTA OF CATS - EVALUATION OF AN EXTRACTABLE DOPPLER ULTRASOUND PROBE FOR CONTINUOUS MONITORING OF AORTIC BLOOD-FLOW
    MATRE, K
    SEGADAL, L
    CARDIOVASCULAR RESEARCH, 1988, 22 (12) : 855 - 863
  • [45] The use of cough peak flow in the assessment of respiratory function in clinical practice- A narrative literature review
    Brennan, M.
    McDonnell, M. J.
    Duignan, N.
    Gargoum, F.
    Rutherford, R. M.
    RESPIRATORY MEDICINE, 2022, 193
  • [46] Implantable Cook Doppler versus Synovis Flow Coupler use in perforator-based breast reconstruction for postoperative free flap monitoring: outcomes and reliability
    Um, Grace
    Louie, Otway
    Said, Hakim K.
    Neligan, Peter C.
    Mathes, David W.
    JOURNAL OF THE AMERICAN COLLEGE OF SURGEONS, 2013, 217 (03) : S66 - S66
  • [47] Use of Near-infrared Spectroscopy and Implantable Doppler for Postoperative Monitoring of Free Tissue Transfer for Breast Reconstruction: A Systematic Review and Meta-analysis
    Berthelot, Melissa
    Ashcroft, James
    Boshier, Piers
    Hunter, Judith
    Henry, Francis Patrick
    Lo, Benny
    Yang, Guang-Zhong
    Leff, Daniel
    PLASTIC AND RECONSTRUCTIVE SURGERY-GLOBAL OPEN, 2019, 7 (10) : E2437
  • [48] Development of modified laser Doppler flowmetry device for real-time monitoring of esophageal mucosal blood flow: a preclinical assessment with an animal model
    Kawarai, Shun-Ichi
    Katahira, Shintaro
    Miyatake, Midori
    Itagaki, Kota
    Tsuruoka, Noriko
    Haga, Yoichi
    Saiki, Yoshikatsu
    JOURNAL OF ARTIFICIAL ORGANS, 2024, 27 (03) : 284 - 292
  • [49] The use of ultrasound Doppler in dentistry: Pulpal blood flow measurement and its clinical advantage over electric pulp tester
    Ahn, So-yeon
    Kim, Do-hyun
    Park, Sung-ho
    2018 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2018,
  • [50] Use of a hands-free, noninvasive Doppler ultrasound device to measure carotid blood flow during resuscitation from cardiac arrest
    Little, Charles M.
    Larabee, Todd M.
    Cohen-Solal, Eric
    Raju, Balasundar
    Nakagawa, Michael
    Erkamp, Ramon
    Ayati, Shervin
    CIRCULATION, 2006, 114 (18) : 1197 - 1197