Version 8 IMK/IAA MIPAS measurements of CFC-11, CFC-12, and HCFC-22

被引:0
|
作者
Stiller, Gabriele P. [1 ]
von Clarmann, Thomas [1 ]
Glatthor, Norbert [1 ]
Grabowski, Udo [1 ]
Kellmann, Sylvia [1 ]
Kiefer, Michael [1 ]
Laeng, Alexandra [1 ]
Linden, Andrea [1 ]
Funke, Bernd [2 ]
Garcia-Comas, Maya [2 ]
Lopez-Puertas, Manuel [2 ]
机构
[1] Karlsruhe Inst Technol, Inst Meteorol & Climate Res, Karlsruhe, Germany
[2] CSIC, Inst Astrofis Andalucia, Granada, Spain
关键词
ABSORPTION CROSS-SECTIONS; LIMB EMISSION-SPECTRA; ATMOSPHERIC SOUNDING MIPAS; IN-SITU MEASUREMENTS; LIVED TRACE GASES; LEVEL; PROCESSOR; LOWER STRATOSPHERE; MICHELSON INTERFEROMETER; CCL2F2; MEASUREMENTS; INTEGRAL EQUATIONS;
D O I
10.5194/amt-17-1759-2024
中图分类号
P4 [大气科学(气象学)];
学科分类号
0706 ; 070601 ;
摘要
The Michelson Interferometer for Passive Atmospheric Sounding (MIPAS) on Envisat provided infrared limb emission spectra, which were used to infer global distributions of CFC-11, CFC-12, and HCFC-22. Spectra were analysed using constrained non-linear least-squares fitting. Changes with respect to earlier data versions refer to the use of version 8 spectra, the altitude range where the background continuum is considered, details of the regularization and microwindow selection, and the occasional joint fitting of interfering species, the use of new spectroscopic data, the joint fit of a tangent-height-dependent spectral offset, and the use of 2D temperature fields. In the lower stratosphere the error budget is dominated by uncertainties in spectroscopic data, while above this measurement noise is the leading error source. The vertical resolution of CFC-11 and CFC-12 is 2-3 km near the tropopause, about 4 km at 30 km altitude, and 6-10 km at 50 km . The vertical resolution of HCFC-22 is somewhat coarser, 3-4 km at the tropopause and 10-12 km at 35 km altitude. In the altitude range of interest, the horizontal resolution is typically limited by the horizontal sampling of the measurements, not by the smearing of the retrievals. Horizontal information displacement does not exceed 150 km , which can become an issue only for comparisons with model simulations with high horizontal resolution or localized in situ observations. Along with the regular data product, an alternative representation of the data on a coarser vertical grid is offered. These data can be used without consideration of the averaging kernels. The new data version provides improvement with respect to reduction of biases and improved consistency between the full- and reduced-resolution mission period of MIPAS.
引用
收藏
页码:1759 / 1789
页数:31
相关论文
共 50 条
  • [1] CFC-11, CFC-12 and HCFC-22 ground-based remote sensing FTIR measurements at Reunion Island and comparisons with MIPAS/ENVISAT data
    Zhou, Minqiang
    Vigouroux, Corinne
    Langerock, Bavo
    Wang, Pucai
    Dutton, Geoff
    Hermans, Christian
    Kumps, Nicolas
    Metzger, Jean-Marc
    Toon, Geoff
    De Maziere, Martine
    ATMOSPHERIC MEASUREMENT TECHNIQUES, 2016, 9 (11) : 5621 - 5636
  • [2] HCFC-22 AS A REPLACEMENT FOR CFC-12
    SULEIMAN, YM
    SAID, SAM
    ISMAIL, B
    APPLIED ENERGY, 1994, 49 (01) : 1 - 8
  • [3] SPECTROSCOPIC STUDIES OF THE ADSORPTION AND REACTIONS OF CHLOROFLUOROCARBONS (CFC-11 AND CFC-12) AND HYDROCHLOROFLUOROCARBON (HCFC-22) ON OXIDE SURFACES
    WYLIE, DJ
    COONEY, RP
    SEAKINS, JM
    MILLAR, GJ
    VIBRATIONAL SPECTROSCOPY, 1995, 9 (03) : 245 - 256
  • [4] Measurements of CFC-11, CFC-12, and HCFC-22 total columns in the atmosphere at the St. Petersburg site in 2009-2019
    Polyakov, Alexander
    Poberovsky, Anatoly
    Makarova, Maria
    Virolainen, Yana
    Timofeyev, Yuri
    Nikulina, Anastasiia
    ATMOSPHERIC MEASUREMENT TECHNIQUES, 2021, 14 (08) : 5349 - 5368
  • [5] MIPAS IMK/IAA CFC-11 (CCl3F) and CFC-12 (CCl2F2) measurements: accuracy, precision and long-term stability
    Eckert, E.
    Laeng, A.
    Lossow, S.
    Kellmann, S.
    Stiller, G.
    von Clarmann, T.
    Glatthor, N.
    Hoepfner, M.
    Kiefer, M.
    Oelhaf, H.
    Orphal, J.
    Funke, B.
    Grabowski, U.
    Haenel, F.
    Linden, A.
    Wetzel, G.
    Woiwode, W.
    Bernath, P. F.
    Boone, C.
    Dutton, G. S.
    Elkins, J. W.
    Engel, A.
    Gille, J. C.
    Kolonjari, F.
    Sugita, T.
    Toon, G. C.
    Walker, K. A.
    ATMOSPHERIC MEASUREMENT TECHNIQUES, 2016, 9 (07) : 3355 - 3389
  • [6] THE ATMOSPHERIC LIFETIMES OF CFC-11 AND CFC-12
    OWENS, AJ
    STEED, JM
    MILLER, C
    FILKIN, DL
    JESSON, JP
    GEOPHYSICAL RESEARCH LETTERS, 1982, 9 (06) : 700 - 703
  • [7] THE ATMOSPHERIC LIFETIMES OF CFC-11 AND CFC-12
    OWENS, AJ
    STEED, JM
    MILLER, C
    FILKIN, DL
    JESSON, JP
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1982, 183 (MAR): : 49 - FLUO
  • [8] Diffusion and permeation of CFC-11, CFC-12, CFC-114, HCFC-22, and FC-14 through polymer films. The relevance to insulation foams
    Brandreth, Dale A.
    Mukherjee, Partha S.
    Journal of thermal insulation, 1991, 15 : 57 - 76
  • [9] Measurements of the diffusion coefficients of CFC-11 and CFC-12 in pure water and seawater
    Zheng, M
    De Bruyn, WJ
    Saltzman, ES
    JOURNAL OF GEOPHYSICAL RESEARCH-OCEANS, 1998, 103 (C1): : 1375 - 1379
  • [10] PERFORMANCE ANALYSIS OF A DROP-IN-REPLACEMENT BLEND FOR CFC-12, CFC-502, AND HCFC-22
    SAMI, SM
    TULEJ, PJ
    INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 1994, 18 (01) : 49 - 56