Experimental study on performance assessment of photovoltaic/thermal-thermoelectric generator systems: Bifacial and tandem types

被引:4
|
作者
Gao, Yuanzhi [1 ]
Ji, Jiahong [1 ]
Cui, Qi [1 ]
Dai, Zhaofeng [1 ]
Chen, Bo [1 ]
Wang, Changling [1 ]
Wu, Dongxu [1 ]
Xu, Guoying [1 ,2 ]
Zhang, Xiaosong [1 ,2 ]
机构
[1] Southeast Univ, Sch Energy & Environm, Nanjing 210096, Peoples R China
[2] Minist Educ, Engn Res Ctr Bldg Equipment Energy & Environm, Beijing, Peoples R China
基金
中国国家自然科学基金;
关键词
Solar energy; Photovoltaic/thermal; Thermoelectric generator; Bifacial and tandem types;
D O I
10.1016/j.enconman.2023.117591
中图分类号
O414.1 [热力学];
学科分类号
摘要
The utilization of photovoltaic/thermal-thermoelectric generator (PV/T-TEG) systems holds great promise for achieving efficient utilization of the full solar spectrum. However, the conventional tandem structure design fails to effectively address the issue of temperature mismatch between the PV and TEG components during operation, highlighting the need for an innovative solution. To address this limitation, an innovative bifacial PV/T-TEG system was developed in this study. A practical test setup was employed to compare the performance of the conventional tandem system with the novel bifacial system under controlled laboratory conditions. The influences of solar radiation and water flow rate on the temperature, electrical, and thermal characteristics of both system configurations were thoroughly investigated and analyzed. The experimental findings unequivocally demonstrate that the recommended bifacial system exhibits lower average PV module temperature and a larger temperature difference in the TEG component when compared to the conventional tandem configuration. Specifically, the temperature reduction in the PV component could be higher than 18 K, while the improvement in temperature difference in the TEG component was larger than 5 K. Moreover, both the PV and TEG components show significantly enhanced power output. The PV power output experiences an improvement ranging from 4.7% to 12.7%, while the maximum power enhancement ratio for TEG reaches 27.8%. Additionally, a notable enhancement of 17% in thermal efficiency is observed when comparing the two systems. The thermal efficiency of the bifacial system improves by 8.37%, and for the tandem system, the improvement is 10.73%, achieved by adjusting the water flow rates.
引用
收藏
页数:12
相关论文
共 50 条
  • [41] Performance Analysis of Stacked Photovoltaic-Thermoelectric Generator Using Mathematical Thermal-Electrical Model
    Alnahhal, Ahmed Issa
    Plesz, Balazs
    2023 29TH INTERNATIONAL WORKSHOP ON THERMAL INVESTIGATIONS OF ICS AND SYSTEMS, THERMINIC, 2023,
  • [42] Prototype of a novel hybrid concentrator photovoltaic/thermal and solar thermoelectric generator system for outdoor study
    Indira, Sridhar Sripadmanabhan
    Vaithilingam, Chockalingam Aravind
    Sivasubramanian, Ramsundar
    Chong, Kok-Keong
    Narasingamurthi, Kulasekharan
    Saidur, R.
    RENEWABLE ENERGY, 2022, 201 : 224 - 239
  • [43] Theoretical and Experimental Study on a Thermoelectric Generator Using Concentrated Solar Thermal Energy
    G. Muthu
    S. Shanmugam
    AR. Veerappan
    Journal of Electronic Materials, 2019, 48 : 2876 - 2885
  • [44] Hybrid photovoltaic and thermoelectric generator systems with thermal wheel Ventilation: A sustainable approach to residential heating and cooling
    Congxiang, Tian
    Guoqing, Zhu
    Yong, Yang
    ENGINEERING SCIENCE AND TECHNOLOGY-AN INTERNATIONAL JOURNAL-JESTECH, 2025, 62
  • [45] Assessment of photovoltaic performance and carbon emission reduction potential of bifacial PV systems for regional grids in China
    Su, Xiaoxiao
    Luo, Chenglong
    Ji, Jie
    Xi, Xiping
    Chen, Xinzhu
    Yu, Yanshun
    Wen, Jin
    Zou, Wu
    SOLAR ENERGY, 2024, 269
  • [46] Numerical and experimental performance evaluation of a laser-concentrated photovoltaic-thermoelectric generator hybrid system
    Li, Yuemei
    Zhang, Zhiguo
    Zhang, Haojie
    Xiao, Ziyang
    Li Luming
    Jiang, Peng
    OPTICS EXPRESS, 2022, 30 (11) : 19465 - 19478
  • [47] Numerical study on the thermal and electrical performance of an annular thermoelectric generator under pulsed heat power with different types of input functions
    Asaadi, Soheil
    Khalilarya, Shahram
    Jafarmadar, Samad
    ENERGY CONVERSION AND MANAGEMENT, 2018, 167 : 102 - 112
  • [48] Theoretical and experimental investigation of a photovoltaic/thermal panel partially equipped with thermoelectric generator under unstable operating conditions
    Nikzad, Mehdi
    Zamen, Mohammad
    Ahmadi, Mohammad Hossein
    INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2022, 46 (05) : 6790 - 6805
  • [49] Experimental and Numerical Study on Thermoelectric Generator Performance Applied to a Condensing Combi Boiler
    Baskaya, Senol
    Karaaslan, Salih
    Calisir, Tamer
    Yilmazoglu, M. Zeki
    Yilmaz, Turgut O.
    HEAT TRANSFER ENGINEERING, 2015, 36 (14-15) : 1292 - 1302
  • [50] Performance assessment of bifacial and monofacial PV systems on different types of soils in a low-latitude site
    Dias, Douglas Lamas
    Rampinelli, Giuliano Arns
    Garrido, Gustavo Nofuentes
    Tejero, Jorge Aguilera
    Ortin, Mariano Sidrach de Cardona
    Bremermann, Leonardo Elizeire
    RENEWABLE ENERGY, 2025, 246