A Novel Fractional-Order Active Disturbance Rejection Load Frequency Control Based on An Improved Marine Predator Algorithm

被引:3
|
作者
He, Weichao [1 ]
Zheng, Yuemin [2 ]
Tao, Jin [2 ]
Zhou, Yujuan [1 ]
Wen, Jiayan [1 ,3 ]
Sun, Qinglin [2 ]
机构
[1] Guangxi Univ Sci & Technol, Sch Automat, Liuzhou 545616, Peoples R China
[2] Nankai Univ, Coll Artificial Intelligence, Tianjin 300350, Peoples R China
[3] Guangxi Univ Sci & Technol, Res Ctr Intelligent Cooperat & Cross Applicat, Liuzhou 545616, Peoples R China
基金
中国国家自然科学基金; 美国国家科学基金会;
关键词
automatic generation control; fractional-order disturbance rejection controller; marine predator algorithm; load frequency control; five-area interconnected power system; RENEWABLE ENERGY-SOURCES; POWER-SYSTEMS;
D O I
10.3390/su15139853
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Load frequency control (LFC) serves as a crucial component of automatic generation control in renewable energy power systems. Its primary objective is to maintain a balance between the output power of generators and the load demand, thereby ensuring system frequency stability. However, integrating renewable energy sources into power systems brings forth several challenges, such as low power quality and poor system stability due to their uncontrollable nature. To enhance the response speed, stability, and disturbance rejection capabilities of LFC, a novel fractional-order active disturbance rejection controller (NFOADRC) based on an improved marine predator algorithm (IMPA) has been designed in this paper. By leveraging the wide frequency-response range and non-local memory of NFOADRC, a more precise prediction and compensation of rapid oscillations in the system can be achieved. Additionally, the IMPA can be utilized for efficient parameter tuning, enabling a more accurate adjustment of the controller. Subsequently, the combined application of these approaches can be applied to two-area interconnected power systems with a solar thermal power plant (STPP) and a five-area interconnected power system including a wind turbine generator (WTG), photovoltaic (PV) cells, hydro turbine, and gas turbine. The simulation results confirm that the proposed control strategy effectively minimizes the undershoot and overshoot of frequency deviation in the power system. It achieves a faster stabilization of the load frequency, leading to enhanced power quality.
引用
收藏
页数:23
相关论文
共 50 条
  • [31] Fractional-Order Active Disturbance Rejection Control with Fuzzy Self-Tuning for Precision Stabilized Platform
    Zhao, Jianjian
    Zhao, Tao
    Liu, Nian
    ENTROPY, 2022, 24 (11)
  • [32] High-order sliding mode-based robust active disturbance rejection control for uncertain fractional-order nonlinear systems
    Alouane, Sofiane
    Djeghali, Nadia
    Bettayeb, Maamar
    Hamoudi, Ahcene
    INTERNATIONAL JOURNAL OF SYSTEMS SCIENCE, 2025,
  • [33] Parameterization of Active Disturbance Rejection Controller for Load Frequency Control
    Rahman, Md. Mijanur
    Chowdhury, A. Hasib
    2014 INTERNATIONAL CONFERENCE ON ELECTRICAL AND COMPUTER ENGINEERING (ICECE), 2014, : 552 - 555
  • [34] Adaptive Load Frequency Control and Optimization Based on TD3 Algorithm and Linear Active Disturbance Rejection Control
    Zheng, Yuemin
    Tao, Jin
    Sun, Qinglin
    Sun, Hao
    Sun, Mingwei
    Chen, Zengqiang
    NEURAL INFORMATION PROCESSING, ICONIP 2023, PT I, 2024, 14447 : 436 - 447
  • [35] Fractional order active disturbance rejection control with the idea of cascaded fractional order integrator equivalence
    Chen, Pengchong
    Luo, Ying
    Zheng, WeiJia
    Gao, Zhiqiang
    Chen, YangQuan
    ISA TRANSACTIONS, 2021, 114 : 359 - 369
  • [36] Fractional-Order Fuzzy PID for the Egyptian Load Frequency Control
    Ghany, M. A. Abdel
    Ghany, A. M. Abdel
    Bensenouci, A.
    Bensenouci, M. A.
    PROCEEDINGS OF 2016 EIGHTEENTH INTERNATIONAL MIDDLE EAST POWER SYSTEMS CONFERENCE (MEPCON), 2016, : 954 - 961
  • [37] A Fractional-Order ADRC Architecture for a PMSM Position Servo System with Improved Disturbance Rejection
    Wang, Shaohua
    Gan, He
    Luo, Ying
    Luo, Xin
    Chen, Yangquan
    FRACTAL AND FRACTIONAL, 2024, 8 (01)
  • [38] Fractional-Order Active Disturbance Rejection Controller Design for Large Radio Telescope Antenna
    Jiang, Jian-Yu
    Wu, Bin
    Zhou, Ting
    INTERNATIONAL JOURNAL OF ANTENNAS AND PROPAGATION, 2022, 2022
  • [39] Fractional-Order Linear Active Disturbance Rejection Control Strategy for Grid-Side Current of PWM Rectifiers
    Pan, Zhifeng
    Wang, Xiaohong
    Zheng, Ziyi
    Tian, Lianfang
    IEEE JOURNAL OF EMERGING AND SELECTED TOPICS IN POWER ELECTRONICS, 2023, 11 (04) : 3827 - 3838
  • [40] Fractional-Order PIλDμ and Active Disturbance Rejection Control of Nonlinear Two-Mass Drive System
    Erenturk, Koksal
    IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2013, 60 (09) : 3806 - 3813