Design and Testing of a Prototype ASIC for the MTPC Readout at CSNS Back-n White Neutron Source

被引:1
|
作者
Li, Jiaming [1 ,2 ]
Zhao, Lei [1 ,2 ]
Qin, Jiajun [1 ,2 ]
Xu, Zhisen [1 ,2 ]
Yu, Jiashu [1 ,2 ]
Liu, Shubin [1 ,2 ]
An, Qi [1 ,2 ]
机构
[1] Univ Sci & Technol China, State Key Lab Particle Detect & Elect, Hefei 230026, Peoples R China
[2] Univ Sci & Technol China, Dept Modern Phys, Hefei 230026, Peoples R China
基金
中国国家自然科学基金;
关键词
Application-specific integrated circuit (ASIC); back-streaming neutrons; charge sensitive amplifier (CSA); front-end electronics; multipurpose time projection chamber (MTPC);
D O I
10.1109/TNS.2022.3210754
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In this article, a prototype application-specific integrated circuit (ASIC) for the multipurpose time projection chambers (MTPCs) at back-streaming white neutron source is presented. The ASIC integrates 16 readout channels and is fabricated in a 0.18-mu m CMOS process. Each channel consists of a charge sensitive amplifier (CSA), a pole-zero cancellation (PZC), two bridged-T shapers, a baseline holder, and a fully differential output buffer. It provides the selectable charge ranges of 2 and 10 pC, the programmable peaking times from 110 ns to 1 mu s, and an adjustable output common-mode voltage from 0.7 to 1.25 V. The ASIC has already been tested, and all the results meet the requirements. In the case of 100-pF input capacitance, 2-pC charge range, and 1-mu s peaking time, it features a maximum integral nonlinearity (INL) of 0.48% and an equivalent noise charge (ENC) of 0.749 fC, which makes the signal-to-noise ratio (SNR) at full-scale input over 2600. In particular, a crosstalk rejection ratio of 63 dB is obtained in this prototype ASIC using the baseline holder circuit in each channel to generate references for single-ended to differential conversion and isolate noise as well as crosstalk from the reference path.
引用
收藏
页码:1030 / 1039
页数:10
相关论文
共 50 条
  • [31] Real-time digital trigger system for GTAF-II at CSNS Back-n white neutron source
    Xie, L.
    Cao, P.
    Yu, T.
    Tang, X.
    Jiang, Z.
    An, Q.
    Huang, X.
    Li, C.
    Li, J.
    Gu, M.
    Zhang, Q.
    Luan, G.
    Ruan, X.
    He, G.
    Ren, J.
    Bai, J.
    Bao, J.
    Bao, Y.
    Chen, H.
    Chen, Q.
    Chen, Y.
    Chen, Z.
    Cui, Z.
    Fan, R.
    Feng, C.
    Gao, K.
    Gao, X.
    Han, C.
    Han, Z.
    He, Y.
    Hong, Y.
    Hu, Y.
    Huang, H.
    Jiang, H.
    Jiang, W.
    Jing, H.
    Kang, L.
    Li, B.
    Li, Q.
    Li, X.
    Li, Y.
    Liu, J.
    Liu, R.
    Liu, S.
    Liu, X.
    Long, Z.
    Ning, C.
    Niu, M.
    Qi, B.
    Ren, Z.
    JOURNAL OF INSTRUMENTATION, 2021, 16 (10)
  • [32] Back-n white neutron facility at CSNS and first-year nuclear data measurements
    Tang, Jingyu
    ND 2019: INTERNATIONAL CONFERENCE ON NUCLEAR DATA FOR SCIENCE AND TECHNOLOGY, 2020, 239
  • [33] Measurement of the relative neutron sensitivity curve of a LaBr3(Ce) scintillator based on the CSNS Back-n white neutron source
    Liu, Jian
    Wang, Dongming
    Fu, Yuecheng
    Li, Zhongbao
    Yi, Han
    Yi, Longtao
    CHINESE PHYSICS B, 2023, 32 (10)
  • [34] Measurement of the relative neutron sensitivity curve of a LaBr3(Ce)scintillator based on the CSNS Back-n white neutron source
    刘建
    王东明
    甫跃成
    李忠宝
    易晗
    易龙涛
    Chinese Physics B, 2023, 32 (10) : 48 - 54
  • [35] Prototype of readout electronics for GAEA gamma spectrometer of Back-n facility at CSNS (vol 17, P03022, 2022)
    Xie, L.
    Cao, P.
    Yu, T.
    Jiang, Z.
    An, Q.
    Li, J.
    Li, C.
    Wu, X.
    Wang, Z.
    Bai, H.
    Bai, J.
    Bao, J.
    Chen, Q.
    Chen, Y.
    Chen, Z.
    Cui, Z.
    Fan, A.
    Fan, R.
    Feng, C.
    Feng, F.
    Gao, K.
    Gu, M.
    Han, C.
    Han, Z.
    He, G.
    He, Y.
    Hong, Y.
    Hu, Y.
    Huang, H.
    Jia, W.
    Jiang, H.
    Jiang, W.
    Jin, Z.
    Kang, L.
    Li, B.
    Li, G.
    Li, Q.
    Li, X.
    Li, Y.
    Liu, J.
    Liu, R.
    Liu, S.
    Luan, G.
    Ning, C.
    Qi, B.
    Ren, J.
    Ren, Z.
    Ruan, X.
    Song, Z.
    Sun, K.
    JOURNAL OF INSTRUMENTATION, 2022, 17 (08):
  • [36] CSNS Back-n Neutron Time-of-flight Measurement Based on SCA Waveform-sampling Readout Electronics
    Zhu D.
    Chen Z.
    Yi H.
    Gao K.
    Feng C.
    Fan R.
    Sun K.
    Jiang W.
    Li Q.
    Li Y.
    Liu S.
    Yuanzineng Kexue Jishu/Atomic Energy Science and Technology, 2020, 54 (06): : 1005 - 1012
  • [37] Design and Test of Collimator for Back-streaming White Neutron Source for CSNS
    Yu Y.
    Jing H.
    Ning C.
    He Y.
    Wang P.
    Tang J.
    Kang L.
    Ruan X.
    Ren J.
    Yuanzineng Kexue Jishu/Atomic Energy Science and Technology, 2019, 53 (12): : 2447 - 2453
  • [38] Detector calibration based on secondary protons of Back-n white neutron source
    Jiang Wei
    Jiang Hao-Yu
    Yi Han
    Fan Rui-Rui
    Cui Zeng-Qi
    Sun Kang
    Zhang Guo-Hui
    Tang Jing-Yu
    Sun Zhi-Jia
    Ning Chang-Jun
    Gao Ke-Qing
    An Qi
    Bai Huai-Yong
    Bao Jie
    Bao Yu
    Cao Ping
    Chen Hao-Lei
    Chen Qi-Ping
    Chen Yong-Hao
    Chen Yu-Kai
    Chen Zhen
    Feng Chang-Qing
    Gu Min-Hao
    Han Chang-Cai
    Han Zi-Jie
    He Guo-Zhun
    He Yong-Cheng
    Hong Yang
    Huang Han-Xiong
    Huang Wei-Ling
    Huang Xi-Ru
    Ji Xiao-Lu
    Ji Xu-Yang
    Jiang Zhi-Jie
    Jing Han-Tao
    Kang Ling
    Kang Ming-Tao
    Li Bo
    Li Chao
    Li Jia-Wen
    Li Lun
    Li Qiang
    Li Xiao
    Li Yang
    Liu Rong
    Liu Shu-Bin
    Liu Xing-Yan
    Luan Guang-Yuan
    Mu Qi-Li
    Qi Bin-Bin
    ACTA PHYSICA SINICA, 2021, 70 (08)
  • [39] Measurement of the neutron energy spectrum of Back-n #ES1 at CSNS
    Chen, Yonghao
    Luan, Guangyuan
    Bao, Jie
    Jing, Hantao
    An, Qi
    Bai, Huaiyong
    Cao, Ping
    Chen, Qiping
    Cheng, Pinjing
    Cui, Zengqi
    Fan, Ruirui
    Feng, Changqing
    Gu, Minhao
    Guo, Fengqin
    Han, Changcai
    Han, Zijie
    He, Guozhu
    He, Yongcheng
    He, Yuefeng
    Huang, Hanxiong
    Huang, Weiling
    Huang, Xiru
    Ji, Xiaolu
    Ji, Xuyang
    Jiang, Haoyu
    Jiang, Wei
    Kang, Ling
    Kang, Mingtao
    Li, Bo
    Li, Lun
    Li, Qiang
    Li, Xiao
    Li, Yang
    Liu, Rong
    Liu, Shubin
    Liu, Xingyan
    Ma, Yinglin
    Ning, Changjun
    Qi, Binbin
    Ren, Jie
    Ruan, Xichao
    Song, Zhaohui
    Sun, Hong
    Sun, Xiaoyang
    Sun, Zhijia
    Tan, Zhixin
    Tang, Hongqing
    Tang, Jingyu
    Wang, Pengcheng
    Wang, Qi
    ND 2019: INTERNATIONAL CONFERENCE ON NUCLEAR DATA FOR SCIENCE AND TECHNOLOGY, 2020, 239
  • [40] First experiment on neutron resonance radiography with a Micromegas detector at the Back-n white neutron source
    Gao, Keqing
    Yi, Han
    Zhang, Qingmin
    Fan, Ruirui
    Li, Yang
    Li, Qiang
    Zhu, Danyang
    Chen, Zhen
    Chen, Haolei
    Tang, Jingyu
    Feng, Changqing
    An, Qi
    Bai, Huaiyong
    Bao, Jie
    Bao, Yu
    Cao, Ping
    Chen, Qiping
    Chen, Yonghao
    Chen, Yukai
    Cui, Zengqi
    Gu, Minhao
    Han, Changcai
    Han, Zijie
    He, Guozhu
    He, Yongcheng
    Hong, Yang
    Huang, Hanxiong
    Huang, Weiling
    Huang, Xiru
    Ji, Xiaolu
    Ji, Xuyang
    Jiang, Haoyu
    Jiang, Wei
    Jiang, Zhijie
    Jing, Hantao
    Kang, Ling
    Kang, Mingtao
    Li, Bo
    Li, Chao
    Li, Jiawen
    Li, Lun
    Li, Xiao
    Liu, Rong
    Liu, Shubin
    Liu, Xingyan
    Luan, Guangyuan
    Mu, Qili
    Ning, Changjun
    Qi, Binbin
    Ren, Jie
    JOURNAL OF INSTRUMENTATION, 2021, 16 (02)