To evaluate the use and clinical effect of intermittently scanned continuous glucose monitoring in adults with type 1 diabetes: Results of a multicentre study

被引:9
|
作者
Moreno-Fernandez, Jesus [1 ]
Sastre, Julia [2 ]
Pines, Pedro [3 ]
Calderon-Vicente, Dulce [4 ]
Gargallo, Javier [5 ]
Munoz-Rodriguez, Jose-Ramon [6 ]
机构
[1] Ciudad Real Gen Univ Hosp, Serv Endocrinol & Nutr, Ciudad Real, Spain
[2] Toledo Univ Hosp, Serv Endocrinol & Nutr, Toledo, Spain
[3] Albacete Univ Hosp, Serv Endocrinol & Nutr, Albacete, Spain
[4] Virgen de la Luz Hosp, Serv Endocrinol & Nutr, Cuenca, Spain
[5] Santa Barbara Hosp, Serv Endocrinol & Nutr, Ciudad Real, Spain
[6] Ciudad Real Gen Univ Hosp, Translat Res Unit, Ciudad Real, Spain
来源
ENDOCRINOLOGIA DIABETES Y NUTRICION | 2023年 / 70卷 / 04期
关键词
Continuous glucose monitoring; Flash; Hypoglycaemia; Type; 1; diabetes; ASSOCIATION; FREQUENCY;
D O I
10.1016/j.endien.2023.03.013
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aim: To evaluate the use and clinical effect of intermittently scanned continuous glucose monitoring (isCGM) in adults with type 1 diabetes (T1D) in a public health service scenario. Method: Cross-sectional retrospective analysis of all patients with T1D and medical indication for isCGM use from a cohort followed since 2010 at Castilla-La Mancha Public Health Service (Spain). Primary outcome was HbA1c change during the first year of follow-up after isCGM initiation. Secondary outcomes included evaluation of self-monitoring of blood glucose (SMBG), isCGM and insulin use, along with glycometric indexes. Results: A total of 945 T1D patients were analyzed. Median age was 49.5 years (IQ range 19.0 years) and T1D duration of 28.9 years (IQ range 14.0 years). The most frequent insulin therapy alternatives were multiple daily injections (85%) followed by insulin pump (11%). Eighty percent of the patients were active isCGM users with a 90% of adherence to the device. Patients showed a mean daily scan frequency of 10.1 +/- 6.4 scans/day. Daily SMBG reduced by -3.5 test/day [95% CI -3.7, -3.2; P < 0.001]. We detected an HbA1c reduction of -0.3% (-4 mmol/mol) [95% CI -0.2, -0.4 (-3, -5); P < 0.001] at the end of the follow-up. An inverse correlation between HbA1c levels at the end of the follow-up and daily frequency of isCGM scanning (R = -0.34, P < 0.001) was observed. Dropout rate was 4%, and 4% of patients were not willing to use isCGM. Conclusions: Adult patients with T1D improved glycaemic control after isCGM initiation in a public health service scenario. Despite described clinical benefits, a higher than expected percentage of patients were not using isCGM technology. NCT05095610. (c) 2023 SEEN y SED. Published by Elsevier Espana, S.L.U. All rights reserved.
引用
收藏
页码:270 / 276
页数:7
相关论文
共 50 条
  • [31] Comparison of Glycemic Metrics Measured Simultaneously by Intermittently Scanned Continuous Glucose Monitoring and Real-Time Continuous Glucose Monitoring in Pregnant Women with Type 1 Diabetes
    Norgaard, Sidse Kjaerhus
    Mathiesen, Elisabeth Reinhardt
    Norgaard, Kirsten
    Ringholm, Lene
    DIABETES TECHNOLOGY & THERAPEUTICS, 2021, 23 (10) : 665 - 672
  • [32] Performance of the Intermittently Scanned Continuous Glucose Monitoring (isCGM) System during a High Oral Glucose Challenge in Adults with Type 1 Diabetes—A Prospective Secondary Outcome Analysis
    Moser, Othmar
    Tripolt, Norbert
    Pferschy, Peter
    Obermayer, Anna
    Kojzar, Harald
    Mueller, Alexander
    Yildirim, Hakan
    Sourij, Caren
    Eckstein, Max
    Sourij, Harald
    Biosensors, 2021, 11 (01):
  • [33] Intermittently scanned continuous glucose monitoring is associated with a long-term glucose-lowering effect for type 1 diabetes patients in poor glycaemic control
    Jensen, M. H.
    Cichosz, S. L.
    Gustenhoff, P.
    Nikontovic, A.
    Hejlesen, O.
    Vestergaard, P.
    DIABETOLOGIA, 2022, 65 (SUPPL 1) : S52 - S52
  • [34] Painless and discrete intermittently scanned continuous glucose monitoring in gestational diabetes: as accurate as fingersticks?
    Hussain, Farrah N.
    Feldman, Kristina M.
    Raymond, Samantha
    Scarpelli-Shchur, Sophia
    Strauss, Tirtza Spiegel
    Al-Ibraheemi, Zainab
    Brustman, Lois
    AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 2022, 226 (01) : S570 - S571
  • [35] In type 1 diabetes, real-time vs. intermittently scanned continuous glucose monitoring improved glycemic control
    Olson, Darin E.
    ANNALS OF INTERNAL MEDICINE, 2021, 174 (10) : JC119 - JC119
  • [36] CGM-BASED CLINICAL TARGETS IN ADULTS WITH TYPE1 AND TYPE2 DIABETES USING INTERMITTENTLY SCANNED CONTINUOUS GLUCOSE MONITORING (FREESTYLE LIBRE SYSTEM): AN ITALIAN EXPERIENCE
    Morpurgo, P.
    Rossi, A.
    Lunati, M. E.
    Chebat, E.
    Gandolfi, A.
    Laneri, M.
    Fiorina, P.
    DIABETES TECHNOLOGY & THERAPEUTICS, 2020, 22 : A135 - A136
  • [37] Intermittently scanned continuous glucose monitoring is associated with lower spontaneous abortion rate compared with conventional blood glucose monitoring in pregnant women with type 1 diabetes: An observational study
    Lemaitre, Madleen
    Faiz, Kenza
    Baudoux, Florence
    Subtil, Damien
    Vambergue, Anne
    DIABETES & VASCULAR DISEASE RESEARCH, 2022, 19 (06):
  • [38] Cost–utility analysis of Dexcom G6 real-time continuous glucose monitoring versus FreeStyle Libre 1 intermittently scanned continuous glucose monitoring in adults with type 1 diabetes in Belgium
    Margaretha M. Visser
    Astrid Van Muylder
    Sara Charleer
    John J. Isitt
    Stéphane Roze
    Christophe De Block
    Toon Maes
    Gerd Vanhaverbeke
    Frank Nobels
    Bart Keymeulen
    Chantal Mathieu
    Jeroen Luyten
    Pieter Gillard
    Nick Verhaeghe
    Diabetologia, 2024, 67 : 650 - 662
  • [39] Preserved C-peptide secretion is associated with higher time in range (TIR) on intermittently scanned continuous glucose monitoring in Chinese adults with type 1 diabetes
    Liu, Wei
    Ma, Yunke
    Cai, Xiaoling
    Zhu, Yu
    Zhang, Mingxia
    Li, Juan
    Chen, Jing
    Shi, Dawei
    Ji, Linong
    ENDOCRINE CONNECTIONS, 2022, 11 (11)
  • [40] Performance of the Intermittently Scanned Continuous Glucose Monitoring (isCGM) System during a High Oral Glucose Challenge in Adults with Type 1 Diabetes-A Prospective Secondary Outcome Analysis
    Moser, Othmar
    Tripolt, Norbert
    Pferschy, Peter
    Obermayer, Anna
    Kojzar, Harald
    Mueller, Alexander
    Yildirim, Hakan
    Sourij, Caren
    Eckstein, Max
    Sourij, Harald
    BIOSENSORS-BASEL, 2021, 11 (01):