Design and optimization of a combined heat and power system with a fluidized-bed combustor and stirling engine

被引:2
|
作者
Chen, Wen-Lih [1 ]
Sirisha, Vadlakonda [1 ]
Yu, Chi-Yuan [1 ]
Wang, Yan-Ru [1 ]
Dai, Ming -Wei [1 ]
Lasek, Janusz [2 ]
Li, Yueh-Heng [1 ,3 ]
机构
[1] Natl Cheng Kung Univ, Dept Aeronaut & Astronaut, Tainan 701, Taiwan
[2] Inst Energy & Fuel Proc Technol, Zabrze 41803, Poland
[3] Natl Cheng Kung Univ, Int Doctoral Degree Program Energy Engn, Tainan 701, Taiwan
关键词
Combined heat and power (CHP) system; Taguchi method; Stirling engine (SE); SMALL-SCALE; BIOMASS; FLAME; COCOMBUSTION; GENERATION; BEHAVIOR;
D O I
10.1016/j.energy.2024.130709
中图分类号
O414.1 [热力学];
学科分类号
摘要
In this study, a fluidized -bed biofuel system was integrated with a Stirling engine (SE) to create a combined heat and power (CHP) system with high energy efficiency. Methods for ensuring the stability of the SE and fluidizedbed combustion were investigated and implemented. The proposed design was tested experimentally, and the system successfully produced electricity from the heat of the flue gas generated during biomass combustion. The Taguchi method was employed to maximize the temperature of the fluidized bed by modifying three parameters: the sand height, air flow rate, and biomass feed rate. The biomass used in this study was discarded mushroom sawdust waste. The biomass feed rate was varied from 9.5 to 17 g/min, and the air flow rate was varied from 50 to 60 L/min. The integrated CHP system was found to yield 90-100 W of electric power and 1077.3 W of heat energy for producing hot water. The oxygen, carbon dioxide, carbon monoxide, and nitric oxide concentrations of the flue gas produced under the optimized system parameters were analyzed, and minimal emissions of carbon monoxide and nitric oxides, which are harmful gases, were discovered. In most experiments on SEs in the literature, liquid or gaseous fuels have been used to power the engine. However, this study successfully used solid biomass fuel to power a practical SE, thus widening the knowledge on the utilization of this renewable energy source for electricity generation. The results of this study indicate that the proposed CHP system is stable, clean, and efficient. This system potentially provides a solution for two problems, namely the disposal of mushroom sawdust waste and the eco-friendly generation of heat and electricity. Therefore, the proposed system is promising for green and sustainable power generation in the future.
引用
收藏
页数:15
相关论文
共 50 条
  • [21] HEAT-TRANSFER TO HORIZONTAL TUBES IMMERSED IN A FLUIDIZED-BED COMBUSTOR
    GREWAL, NS
    MENART, J
    HAJICEK, DR
    ZOBECK, BJ
    POWDER TECHNOLOGY, 1987, 52 (02) : 149 - 159
  • [22] ECONOMIC FEASIBILITY OF PRESSURIZED FLUIDIZED-BED COMBUSTOR POWER-PLANT
    SINGH, G
    MOSKOWITZ, S
    COMBUSTION, 1979, 50 (08): : 22 - 25
  • [23] SIMULATION OF A COMBINED-CYCLE POWER-PLANT BASED ON A PRESSURIZED CIRCULATING FLUIDIZED-BED COMBUSTOR
    HEINBOCKEL, I
    FETT, FN
    HEAT RECOVERY SYSTEMS & CHP, 1995, 15 (02): : 171 - 178
  • [24] OPTIMIZATION OF HEATING WITH HEAT-TREATMENT IN FLUIDIZED-BED
    DRUGE, L
    PANTYA, V
    METAL SCIENCE AND HEAT TREATMENT, 1979, 21 (7-8) : 582 - 584
  • [25] MATHEMATICAL SIMULATION OF A CIRCULATING FLUIDIZED-BED COMBUSTOR
    SARAIVA, PC
    AZEVEDO, JLT
    CARVALHO, MG
    COMBUSTION SCIENCE AND TECHNOLOGY, 1993, 93 (1-6) : 223 - 243
  • [26] PREDICTIVE CONTROL OF A CIRCULATING FLUIDIZED-BED COMBUSTOR
    VENUGOPAL, S
    GUPTA, YP
    BASU, P
    CANADIAN JOURNAL OF CHEMICAL ENGINEERING, 1991, 69 (01): : 130 - 135
  • [27] MODELING OF SULFUR CAPTURE IN A FLUIDIZED-BED COMBUSTOR
    FEE, DC
    WILSON, WI
    CHAMPAGNE, PT
    MACKENZIE, SL
    BRENNAN, DC
    MYLES, KM
    JOHNSON, I
    FAN, LS
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1981, 182 (AUG): : 65 - ENVR
  • [28] Estimation of solids mixing in a fluidized-bed combustor
    Niklasson, F
    Thunman, H
    Johnsson, F
    Leckner, B
    INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 2002, 41 (18) : 4663 - 4673
  • [29] OPERATING EXPERIENCE WITH A FLUIDIZED-BED TEST COMBUSTOR
    HAINLEY, DC
    HAJISULAIMAN, MZ
    YAVUZKURT, S
    SCARONI, AW
    JOURNAL OF ENERGY RESOURCES TECHNOLOGY-TRANSACTIONS OF THE ASME, 1987, 109 (02): : 58 - 65
  • [30] FLUIDIZED-BED HEAT STORE FOR POWER-GENERATION
    CRANFIELD, RR
    JOURNAL OF THE INSTITUTE OF ENERGY, 1980, 53 (417): : 196 - 204