Micro-CT analysis and leakage of bioceramic retrofillings after ultrasonic and Er:YAG laser cavity preparations: an in vitro study

被引:2
|
作者
Markovic, Luka
Ivanisevic, Ana [1 ]
Matijevic, Jurica [1 ]
Chan, Rosalind Sin Man [2 ]
Tsoi, James Kit Hon [2 ]
Snjaric, Damir [3 ]
Gjorgievska, Elizabeta [4 ]
机构
[1] Univ Zagreb, Sch Dent Med, Dept Endodont & Restorat Dent, Zagreb, Croatia
[2] Univ Hong Kong, Fac Dent, Appl Oral Sci & Community Dent Care, Hong Kong, Peoples R China
[3] Univ Rijeka, Sch Dent Med, Dept Endodont & Restorat Dent, Rijeka, Croatia
[4] Univ Ss Cyril & Methodius Skopje, Fac Dent Med, Dept Paediat & Prevent Dent, Skopje, North Macedonia
关键词
Biodentine & TRADE; Erbium; Yttrium Aluminum Garnet laser; Leakage; Micro-CT analysis; Retrograde filling; TotalFill & REG; RRM; END FILLING MATERIALS; CALCIUM SILICATE; BOND STRENGTH; YAG LASER; ER-YAG; CEMENTS; IRRIGATION; DYNAMICS; DENTIN;
D O I
10.1007/s10103-023-03809-y
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The purpose of the study was to determine the influence of preparation techniques on marginal adaptation and sealing of Biodentine (TM) and TotalFill (R) RRM bioceramic retrograde fillings. Fifty-two single-root teeth extracted for periodontal reasons were used. Root canals were instrumented using Reciproc Blue #25 and obturated using a single cone technique with an AH Plus (R) root canal sealer. Retrograde cavities were prepared with Piezomed device (Piezo), Er:YAG laser in short-pulse(SP) and quantum square pulse(QSP) modes and filled with Biodentine (TM) (BD) or TotalFill (R) RRM (TF). There were 6 groups (n=8): (1) Piezo BD, (2) Piezo TF, (3) SP BD, (4) SP TF, (5) QSP BD, and (6) QSP TF, and positive and negative controls (n=2). Micro-CT analysis was performed on two samples from each group. Percentage volumes of internal and external voids in apical 1.5 mm were determined. Rhodamine B dye leakage was done on six samples. The samples were cut longitudinally and examined under a stereomicroscope. Digital recordings were analyzed in ImageJ software. The deepest penetration of color in mm was recorded. The data were statistically analyzed using ANOVA and Duncan's test at the level of significance a=0.05. TotalFill (R) RRM performed significantly better than Biodentine (TM) in terms of sealing (p<0.05) and marginal adaptation, as evaluated by micro-CT. Sealing was significantly better in SP compared to QSP mode preparations (p<0.05). Differences between Piezomed and laser modes were not significantly different (p>0.05). Sealing was statistically significantly better with TotalFill (R) RRM compared to Biodentine (TM) and in Er:YAG SP preparations compared to Er:YAG QSP.
引用
收藏
页数:9
相关论文
共 46 条
  • [31] Analysis of pulp chamber of primary maxillary second molars using 3D micro-CT system: an in vitro study
    Orhan, A. I.
    Orhan, K.
    Ozgul, B. M.
    Oz, F. T.
    EUROPEAN JOURNAL OF PAEDIATRIC DENTISTRY, 2015, 16 (04) : 305 - 310
  • [32] Comparison of Shear Bond Strength of Occlusal Pad Debonding Pliers Before and After Er-YAG Laser Application: An In vitro Study
    Ibrahim, Ali R.
    Ghaib, Nidhal H.
    INTERNATIONAL JOURNAL OF MEDICAL RESEARCH & HEALTH SCIENCES, 2019, 8 (03): : 1 - 6
  • [33] Micromorphological evaluation of enamel surface and the shear bond strength of composite resin after Er:YAG laser irradiation. An ''in vitro'' study
    Eduardo, CP
    Myaki, SI
    Oliveira, WT
    AranaChavez, VE
    Tanji, EY
    5TH CONGRESS OF THE INTERNATIONAL SOCIETY FOR LASERS IN DENTISTRY, 1996, : 41 - 44
  • [34] A comparative study of microleakage through enamel and cementum after laser Er:YAG instrumentation in class V cavity obturations, using scanning electron microscopy
    Bahillo, JG
    Piñón, MR
    Nogueira, JR
    Biedma, BM
    Patiño, PV
    Muñoz, FM
    Varela, MB
    Castro, NB
    JOURNAL OF CLINICAL LASER MEDICINE & SURGERY, 2002, 20 (04): : 197 - 201
  • [35] Bonding Strength of Ceromer with Direct Laser Sintered, Ni-Cr-Based, and ZrO2 Metal Infrastructures After Er:YAG, Nd:YAG, and Ho:YAG Laser Surface Treatments-A Comparative In Vitro Study
    Gorler, Oguzhan
    Ozdemir, Ali Kemal
    PHOTOMEDICINE AND LASER SURGERY, 2016, 34 (08) : 355 - 362
  • [36] Comparative Histopathological Analysis of Human Pulps after Class I Cavity Preparation with a High-Speed Air-Turbine Handpiece or Er:YAG Laser
    Kina, J. F.
    Benitez, P. C.
    Lizarelli, R. F. Z.
    Bagnato, V. S.
    Martinez, T. C.
    Oliveira, C. F.
    Hebling, J.
    Costa, C. A. S.
    LASER PHYSICS, 2008, 18 (12) : 1562 - 1569
  • [37] Scanning Electron Microscope Image Analysis of Bonding Surfaces following Removal of Composite Resin Restoration Using Er: YAG Laser: In Vitro Study
    Babarasul D.O.
    Faraj B.M.
    Kareem F.A.
    Scanning, 2021, 2021
  • [38] Evaluation of the microleakage of different class V cavities prepared by using Er:YAG laser, ultrasonic device, and conventional rotary instruments with two dentin bonding systems (an in vitro study)
    Gullshang Muhammed
    Raad Dayem
    Lasers in Medical Science, 2015, 30 : 969 - 975
  • [39] Evaluation of the microleakage of different class V cavities prepared by using Er:YAG laser, ultrasonic device, and conventional rotary instruments with two dentin bonding systems (an in vitro study)
    Muhammed, Gullshang
    Dayem, Raad
    LASERS IN MEDICAL SCIENCE, 2015, 30 (03) : 969 - 975
  • [40] A Comparative Analysis of the Occluding Effects on Dentinal Tubules With the Use of Er:YAG Laser and a Commercially Available Desensitizing Agent: An In Vitro Scanning Electron Microscopic Study
    Johnson, Lynn
    Soni, Abhishek
    Kaliappan, Satish
    Mishra, Supriya
    Kaushal, Laxmi
    Teware, Sakshi
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2023, 15 (08)