Multi-vendor evaluation of artificial intelligence as an independent reader for double reading in breast cancer screening on 275,900 mammograms

被引:19
|
作者
Sharma, Nisha [1 ]
Ng, Annie Y. [2 ]
James, Jonathan J. [3 ]
Khara, Galvin [2 ]
Ambrozay, Eva [4 ]
Austin, Christopher C. [2 ]
Forrai, Gabor [5 ,6 ]
Fox, Georgia [2 ]
Glocker, Ben [2 ,7 ]
Heindl, Andreas [2 ]
Karpati, Edit [2 ,8 ]
Rijken, Tobias M. [2 ]
Venkataraman, Vignesh [2 ]
Yearsley, Joseph E. [2 ]
Kecskemethy, Peter D. [2 ]
机构
[1] Leeds Teaching Hosp NHS Trust, Leeds, England
[2] Kheiron Med Technol, London, England
[3] Nottingham Univ Hosp NHS Trust, City Hosp, Nottingham Breast Inst, Nottingham, England
[4] MaMMa Egeszsegugy Zrt, Budapest, Hungary
[5] Duna Med Ctr, Budapest, Hungary
[6] GE RAD Kft, Budapest, Hungary
[7] Imperial Coll London, Dept Comp, London, England
[8] Medicover, Budapest, Hungary
基金
英国医学研究理事会; “创新英国”项目;
关键词
Breast cancer screening; digital mammography; artificial intelligence; generalisability; COMPUTER-AIDED DETECTION; RECALL RATES; GUIDELINES; PROGRAMS;
D O I
10.1186/s12885-023-10890-7
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
BackgroundDouble reading (DR) in screening mammography increases cancer detection and lowers recall rates, but has sustainability challenges due to workforce shortages. Artificial intelligence (AI) as an independent reader (IR) in DR may provide a cost-effective solution with the potential to improve screening performance. Evidence for AI to generalise across different patient populations, screening programmes and equipment vendors, however, is still lacking.MethodsThis retrospective study simulated DR with AI as an IR, using data representative of real-world deployments (275,900 cases, 177,882 participants) from four mammography equipment vendors, seven screening sites, and two countries. Non-inferiority and superiority were assessed for relevant screening metrics.ResultsDR with AI, compared with human DR, showed at least non-inferior recall rate, cancer detection rate, sensitivity, specificity and positive predictive value (PPV) for each mammography vendor and site, and superior recall rate, specificity, and PPV for some. The simulation indicates that using AI would have increased arbitration rate (3.3% to 12.3%), but could have reduced human workload by 30.0% to 44.8%.ConclusionsAI has potential as an IR in the DR workflow across different screening programmes, mammography equipment and geographies, substantially reducing human reader workload while maintaining or improving standard of care.
引用
收藏
页数:13
相关论文
共 44 条
  • [41] Screen-detected and interval breast cancer after concordant and discordant interpretations in a population based screening program using independent double reading
    Marit A. Martiniussen
    Silje Sagstad
    Marthe Larsen
    Anne Sofie F. Larsen
    Tone Hovda
    Christoph I. Lee
    Solveig Hofvind
    [J]. European Radiology, 2022, 32 : 5974 - 5985
  • [42] Impact of real-life use of artificial intelligence as support for human reading in a population-based breast cancer screening program with mammography and tomosynthesis
    Elias-Cabot, Esperanza
    Romero-Martin, Sara
    Raya-Povedano, Jose Luis
    Brehl, A. -K.
    Alvarez-Benito, Marina
    [J]. EUROPEAN RADIOLOGY, 2024, 34 (06) : 3958 - 3966
  • [43] "Overview of trials on artificial intelligence algorithms in breast cancer screening - A roadmap for international evaluation and implementation" (vol 167, 111087,2023)
    van Nijnatten, T. J. A.
    Payne, N. R.
    Hickman, S. E.
    Ashrafian, H.
    Gilbert, F. J.
    [J]. EUROPEAN JOURNAL OF RADIOLOGY, 2024, 170
  • [44] Artificial intelligence, BI-RADS evaluation and morphometry: A novel combination to diagnose breast cancer using ultrasonography, results from multi-center cohorts
    Hamyoon, Hessam
    Chan, Wai Yee
    Mohammadi, Afshin
    Kuzan, Taha Yusuf
    Mirza-Aghazadeh-Attari, Mohammad
    Leong, Wai Ling
    Altintoprak, Kuebra Murzoglu
    Vijayananthan, Anushya
    Rahmat, Kartini
    Ab Mumin, Nazimah
    Leong, Sook Sam
    Ejtehadifar, Sajjad
    Faeghi, Fariborz
    Abolghasemi, Jamileh
    Ciaccio, Edward J.
    Acharya, U. Rajendra
    Ardakani, Ali Abbasian
    [J]. EUROPEAN JOURNAL OF RADIOLOGY, 2022, 157