Water layer and radiation damage effects on the orientation recovery of proteins in single-particle imaging at an X-ray free-electron laser

被引:1
|
作者
Juncheng, E. [1 ]
Stransky, Michal [1 ,2 ]
Shen, Zhou [3 ]
Jurek, Zoltan [4 ,5 ]
Fortmann-Grote, Carsten [1 ]
Bean, Richard [1 ]
Santra, Robin [4 ,5 ,6 ]
Ziaja, Beata [2 ,4 ]
Mancuso, Adrian P. [1 ,7 ,8 ]
机构
[1] European XFEL, Holzkoppel 4, D-22869 Schenefeld, Germany
[2] Polish Acad Sci, Inst Nucl Phys, Radzikowskiego 152, PL-31342 Krakow, Poland
[3] Max Planck Inst Struct & Dynam Matter, Luruper Chaussee 149, D-22761 Hamburg, Germany
[4] Deutsch Elektronen Synchrotron DESY, Ctr Free Electron Laser Sci, Notkestr 85, D-22607 Hamburg, Germany
[5] Hamburg Ctr Ultrafast Imaging, Luruper Chaussee 149, D-22761 Hamburg, Germany
[6] Univ Hamburg, Dept Phys, Notkestr 9-11, D-22607 Hamburg, Germany
[7] Diamond Light Source, Harwell Sci & Innovat Campus, Didcot OX11 0DE, Oxon, England
[8] La Trobe Univ, La Trobe Inst Mol Sci, Dept Chem & Phys, Melbourne, Vic 3086, Australia
基金
欧盟地平线“2020”;
关键词
SIMULATION;
D O I
10.1038/s41598-023-43298-1
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
The noise caused by sample heterogeneity (including sample solvent) has been identified as one of the determinant factors for a successful X-ray single-particle imaging experiment. It influences both the radiation damage process that occurs during illumination as well as the scattering patterns captured by the detector. Here, we investigate the impact of water layer thickness and radiation damage on orientation recovery from diffraction patterns of the nitrogenase iron protein. Orientation recovery is a critical step for single-particle imaging. It enables to sort a set of diffraction patterns scattered by identical particles placed at unknown orientations and assemble them into a 3D reciprocal space volume. The recovery quality is characterized by a "disconcurrence" metric. Our results show that while a water layer mitigates protein damage, the noise generated by the scattering from it can introduce challenges for orientation recovery and is anticipated to cause problems in the phase retrieval process to extract the desired protein structure. Compared to these disadvantageous effects due to the thick water layer, the effects of radiation damage on the orientation recovery are relatively small. Therefore, minimizing the amount of residual sample solvent should be considered a crucial step in improving the fidelity and resolution of X-ray single-particle imaging experiments.
引用
收藏
页数:11
相关论文
共 50 条
  • [21] SINGLE-PARTICLE DYNAMICS AND GAIN IN FREE-ELECTRON LASER
    PANDYA, TP
    BALI, LM
    ROY, S
    JOURNAL OF THE PHYSICAL SOCIETY OF JAPAN, 1984, 53 (05) : 1583 - 1586
  • [22] Simple convergent-nozzle aerosol injector for single-particle diffractive imaging with X-ray free-electron lasers
    Kirian, R. A.
    Awel, S.
    Eckerskorn, N.
    Fleckenstein, H.
    Wiedorn, M.
    Adriano, L.
    Bajt, S.
    Barthelmess, M.
    Bean, R.
    Beyerlein, K. R.
    Chavas, L. M. G.
    Domaracky, M.
    Heymann, M.
    Horke, D. A.
    Knoska, J.
    Metz, M.
    Morgan, A.
    Oberthuer, D.
    Roth, N.
    Sato, T.
    Xavier, P. L.
    Yefanov, O.
    Rode, A. V.
    Kuepper, J.
    Chapman, H. N.
    STRUCTURAL DYNAMICS-US, 2015, 2 (04):
  • [23] X-ray Free-Electron Laser
    Ueda, Kiyoshi
    APPLIED SCIENCES-BASEL, 2018, 8 (06):
  • [24] Femtosecond Radiation Experiment Detector for X-Ray Free-Electron Laser (XFEL) Coherent X-Ray Imaging
    Philipp, Hugh T.
    Koerner, Lucas J.
    Hromalik, Marianne S.
    Tate, Mark W.
    Gruner, Sol M.
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2010, 57 (06) : 3795 - 3799
  • [25] Femtosecond Radiation Experiment Detector for X-ray Free-Electron Laser (XFEL) Coherent X-ray Imaging
    Philipp, Hugh T.
    Koerner, Lucas J.
    Hromalik, Marianne S.
    Tate, Mark W.
    Gruner, Sol M.
    2008 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (2008 NSS/MIC), VOLS 1-9, 2009, : 842 - 846
  • [26] Start-to-end simulation of single-particle imaging using ultra-short pulses at the European X-ray Free-Electron Laser
    Fortmann-Grote, Carsten
    Buzmakov, Alexey
    Jurek, Zoltan
    Loh, Ne-Te Duane
    Samoylova, Liubov
    Santra, Robin
    Schneidmiller, Evgeny A.
    Tschentscher, Thomas
    Yakubov, Sergey
    Yoon, Chun Hong
    Yurkov, Michael V.
    Ziaja-Motyka, Beata
    Mancuso, Adrian P.
    IUCRJ, 2017, 4 : 560 - 568
  • [27] Theoretical study of electronic damage in single-particle imaging experiments at x-ray free-electron lasers for pulse durations from 0.1 to 10 fs
    Gorobtsov, O. Yu.
    Lorenz, U.
    Kabachnik, N. M.
    Vartanyants, I. A.
    PHYSICAL REVIEW E, 2015, 91 (06):
  • [28] Radiation damage in protein crystallography at X-ray free-electron lasers
    Nass, Karol Jan
    ACTA CRYSTALLOGRAPHICA A-FOUNDATION AND ADVANCES, 2017, 73 : C1025 - C1025
  • [29] Radiation damage in protein crystallography at X-ray free-electron lasers
    Nass, Karol
    ACTA CRYSTALLOGRAPHICA SECTION D-STRUCTURAL BIOLOGY, 2019, 75 : 211 - 218
  • [30] Damage to inorganic materials illuminated by focused beam of X-ray free-electron laser radiation
    Koyama, Takahisa
    Yumoto, Hirokatsu
    Tono, Kensuke
    Togashi, Tadashi
    Inubushi, Yuichi
    Katayama, Tetsuo
    Kim, Jangwoo
    Matsuyama, Satoshi
    Yabashi, Makina
    Yamauchi, Kazuto
    Ohashi, Haruhiko
    DAMAGE TO VUV, EUV, AND X-RAY OPTICS V, 2015, 9511