Energy, conventional and advanced exergy analysis for the organic Rankine cycle-vapor compression refrigeration combined system driven by low-grade waste heat

被引:18
|
作者
Xia, Xiaoxia [1 ]
Liu, Zhipeng [1 ]
Wang, Zhiqi [1 ]
Zuo, Qingsong [1 ]
Sun, Tong [1 ]
机构
[1] Xiangtan Univ, Sch Mech Engn & Mech, Xiangtan 411105, Peoples R China
关键词
Organic Rankine cycle; Vapor compression refrigeration; Conventional exergy analysis; Advanced exergy analysis; Improvement potential and priority; THERMOECONOMIC ANALYSIS; ABSORPTION-REFRIGERATION; OPTIMIZATION;
D O I
10.1016/j.applthermaleng.2022.119650
中图分类号
O414.1 [热力学];
学科分类号
摘要
Global issues such as energy crisis and environmental pollution have driven the development of waste heat recovery technology. The organic Rankine cycle (ORC)-vapor compression refrigeration (VCR) combined system is a promising solution to achieve refrigeration requirements by recycling waste heat. How to determine the irreversible losses of the system and the improvement priority of the components is of great significance to enhance the system performance. Firstly, the energy and conventional exergy analysis of the ORC-VCR combined system is carried out to obtain thermodynamic performance of the system. Then, the advanced exergy analysis of the system is conducted and the exergy destruction distribution characteristics and improvement potential of the components are obtained. In addition, the interactions between the components are investigated in detail to achieve the improvement priority of the components. Finally, the improvement strategies for each component are proposed based on the influence of the components on the system. The results show that the coefficient of performance (COP) and exergy efficiency of the system are 0.44 and 14.97 %, respectively. The condenser contributes the most (44148 W) to the exergy destruction of the system. The largest endogenous (32935 W), avoidable (28530 W) and endogenous-avoidable (21577 W) exergy destruction also belong to the condenser. The condenser is determined as the most important component to promote system performance. The turbine and compressor have dominant influence on the system and the improvement depends on themselves. While the generator, condenser and evaporator only affect themselves and the improvement depends on all the components of the system. The results can provide theoretical guidance for further improving system performance.
引用
收藏
页数:13
相关论文
共 50 条
  • [31] Simultaneous optimization of multiparameters on a subcritical organic Rankine cycle system for low-grade waste heat recovery
    Zhang, Li
    Li, Chun-Chun
    Li, You-Rong
    Wu, Chun-Mei
    JOURNAL OF MECHANICAL SCIENCE AND TECHNOLOGY, 2019, 33 (01) : 447 - 458
  • [32] Thermodynamic analysis of hybrid heat source driven organic Rankine cycle integrated flash tank vapor-compression refrigeration system
    Ashwni
    Sherwani, Ahmad Faizan
    INTERNATIONAL JOURNAL OF REFRIGERATION, 2021, 129 : 267 - 277
  • [33] Considerations on alternative organic Rankine Cycle congurations for low-grade waste heat recovery
    Woodland, Brandon J.
    Ziviani, Davide
    Braun, James E.
    Groll, Eckhard A.
    ENERGY, 2020, 193 : 1134 - 1150
  • [34] UTILIZATION OF ORGANIC RANKINE CYCLE FOR ANALYZING ENERGY AND EXERGY OF THE WASTE HEAT RECOVERY SYSTEM
    Hossain, Farzad
    Miah, Md Ashrafuzzaman
    SIGMA JOURNAL OF ENGINEERING AND NATURAL SCIENCES-SIGMA MUHENDISLIK VE FEN BILIMLERI DERGISI, 2020, 38 (04): : 1963 - 1976
  • [35] Parametric analysis of organic Rankine cycle based on a radial turbine for low-grade waste heat recovery
    Dong, Bensi
    Xu, Guoqiang
    Li, Tingting
    Luo, Xiang
    Quan, Yongkai
    APPLIED THERMAL ENGINEERING, 2017, 126 : 470 - 479
  • [36] Energy and exergy analyses of a combined cycle Kalina and organic Rankine cycles using waste heat
    Mansoury, Mehdi
    Jafarmadar, Samad
    Khalilarya, Shahram
    INTERNATIONAL JOURNAL OF EXERGY, 2018, 27 (02) : 251 - 286
  • [37] Thermal analysis of solar energy based organic Rankine cycle cascaded with vapor compression refrigeration cycle
    Qureshi, Mohammad Faizan
    Chandio, Mohammad Waqas
    Memon, Abdul Aleem
    Kumar, Laveet
    Awad, Mohamed M.
    ENERGY NEXUS, 2024, 14
  • [38] Situation Analysis of Organic Rankine Cycle system for low-grade heat power generation in China
    Liao Yongxi
    Xiong Bin
    Guo Hui
    2011 ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), 2011,
  • [39] Thermodynamic and Thermo-economic Analysis of Integrated Organic Rankine Cycle for Waste Heat Recovery from Vapor Compression Refrigeration Cycle
    Asim, Muhammad
    Leung, Michael K. H.
    Shan, Zhiqiang
    Li, Yingying
    Leung, Dennis Y. C.
    Ni, Meng
    LEVERAGING ENERGY TECHNOLOGIES AND POLICY OPTIONS FOR LOW CARBON CITIES, 2017, 143 : 192 - 198
  • [40] Advanced exergy, economic, and environmental evaluation of an Organic Rankine Cycle driven dual evaporators vapour-compression refrigeration system using organic fluids
    Goyal, Ashwni
    Rawat, Piyush
    Sherwani, Ahmad Faizan
    Rana, Ramakant
    INTERNATIONAL JOURNAL OF REFRIGERATION, 2023, 150 : 170 - 184