Exergy analysis of a new spray cooling system-based PV/T and heat recovery with application in sow houses

被引:4
|
作者
Ma, Hongqiang [1 ]
Xie, Yue [1 ]
Wang, Shengxun [1 ]
Liu, Yu [1 ]
Ding, Ruixiang [1 ]
机构
[1] East China Jiaotong Univ, Sch Civil Engn & Architecture, Nanchang 330013, Peoples R China
基金
中国国家自然科学基金;
关键词
New spray cooling system; Annual operation modes; Exergy loss; Optimal control parameters; SILICA-GEL; THERMAL PERFORMANCE; EFFICIENCY; ENERGY; STRESS;
D O I
10.1016/j.solener.2023.111828
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The uncertain cooling effect and additional huge primary energy consumption caused by humidity regulation are currently the main problems of traditional environmental regulation systems in sow houses. In this study, a new spray cooling system is proposed based on PV/T and heat recovery in sow houses. Meanwhile, the mathematical models are established for its key equipment and their reliability is verified according to literature data. The results show that the maximum error is less than 14.5 % for the models. Based on the above models, the annual operation modes are determined for the new system. Specifically, its annual operation modes mainly include the cooling season, the heating season, the transitional spring and the transitional autumn. Meanwhile, the exergy loss and energy consumption are analyzed for the new system in four seasons through simulation. The results show that in the cooling and heating seasons, the exergy loss first decreases and then increases with the increase of spray power (SP) and mass flow rate of circulating water (MFRW). In the transition season, the exergy loss decreases with the increase of MFRW, while it first decreases and then increases with the increase of SP. However, the annual energy consumption increases with the increase of SP and MFRW. Aim at the minimum exergy loss of new system, its optimal control parameters are obtained in four seasons through optimization. Specifically, when the mass flow rate of supply air is the minimum ventilation rate required by sows, the optimal SP and MFRW are recommended as 40 kW and 12245 kg/h in the cooling and heating seasons, respectively. Meanwhile, they are recommended as 35 kW and 12245 kg/h in the transition season, respectively. The above research can provide guidance for the improvement of traditional spray cooling systems and the performance optimization of new system.
引用
收藏
页数:16
相关论文
共 50 条
  • [31] Energy, exergy and thermoeconomic analysis of a novel combined cooling and power system using low-temperature heat source and LNG cold energy recovery
    Ghaebi, Hadi
    Parikhani, Towhid
    Rostamzadeh, Hadi
    ENERGY CONVERSION AND MANAGEMENT, 2017, 150 : 678 - 692
  • [32] Experiment and optimization of a new kind once-through heat recovery steam generator (HRSG) based on analysis of exergy and economy
    Li, Jinbo
    Wang, Kunyu
    Cheng, Lin
    APPLIED THERMAL ENGINEERING, 2017, 120 : 402 - 415
  • [33] Exergy analysis and exergetic costs allocation in a novel CCHP system based on organic Rankine and simultaneous heating and cooling heat pump cycles
    Lourenco, Atilio B.
    JOURNAL OF THE BRAZILIAN SOCIETY OF MECHANICAL SCIENCES AND ENGINEERING, 2024, 46 (08)
  • [34] Energy and Exergy Analysis of a New Cogeneration Heating System Based on Condensed Waste-Heat Utilization in the Direct Air Cooling Coal-Fired Power Plant
    Zhang, Hongsheng
    Liu, Xingang
    Liu, Yifeng
    Hao, Ruijun
    Liu, Chengjun
    Duan, Chenghong
    Dou, Zhan
    Qin, Jiyun
    JOURNAL OF ENERGY ENGINEERING, 2022, 148 (02)
  • [36] Energy efficiency analysis of a multifunctional hybrid open absorption system for dehumidification, heating, and cooling: An industrial waste heat recovery application
    Shahzad, Muhammad Kashif
    Ding, Yaqi
    Xuan, Yongmei
    Gao, Neng
    Chen, Guangming
    ENERGY CONVERSION AND MANAGEMENT, 2021, 243
  • [37] Optimized design and application performance analysis of heat recovery hybrid system for radioisotope thermophotovoltaic based on thermoelectric heat dissipation
    Wang, Hongyu
    Xu, Zhiheng
    Wang, Chen
    Hou, Zongbin
    Bian, Mingxin
    Zhuang, Nailiang
    Tao, Haijun
    Wang, Yuqiao
    Tang, Xiaobin
    APPLIED ENERGY, 2024, 355
  • [38] Energy analysis of a novel butterfly serpentine flow-based PV/T and PV/T heat pump system with phase change material - an experimental comparative study
    Prakash, K. B.
    Amarkarthik, A.
    ENERGY SOURCES PART A-RECOVERY UTILIZATION AND ENVIRONMENTAL EFFECTS, 2023, 45 (02) : 5494 - 5507
  • [39] Exergy analysis of LBE-helium heat exchanger in the experimental cooling loop based on accelerator driven sub-critical power system
    Wang, Yongwei
    Zhang, Hang
    Huai, Xiulan
    Li, Xunfeng
    Cai, Jun
    Xi, Wenxuan
    ENERGY CONVERSION AND MANAGEMENT, 2017, 135 : 274 - 280
  • [40] Performance analysis of nanofluid-based spectral splitting PV/T system in combined heating and power application
    Ni, Jun
    Li, Jun
    An, Wei
    Zhu, Tong
    APPLIED THERMAL ENGINEERING, 2018, 129 : 1160 - 1170