Exergy analysis of a new spray cooling system-based PV/T and heat recovery with application in sow houses

被引:4
|
作者
Ma, Hongqiang [1 ]
Xie, Yue [1 ]
Wang, Shengxun [1 ]
Liu, Yu [1 ]
Ding, Ruixiang [1 ]
机构
[1] East China Jiaotong Univ, Sch Civil Engn & Architecture, Nanchang 330013, Peoples R China
基金
中国国家自然科学基金;
关键词
New spray cooling system; Annual operation modes; Exergy loss; Optimal control parameters; SILICA-GEL; THERMAL PERFORMANCE; EFFICIENCY; ENERGY; STRESS;
D O I
10.1016/j.solener.2023.111828
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The uncertain cooling effect and additional huge primary energy consumption caused by humidity regulation are currently the main problems of traditional environmental regulation systems in sow houses. In this study, a new spray cooling system is proposed based on PV/T and heat recovery in sow houses. Meanwhile, the mathematical models are established for its key equipment and their reliability is verified according to literature data. The results show that the maximum error is less than 14.5 % for the models. Based on the above models, the annual operation modes are determined for the new system. Specifically, its annual operation modes mainly include the cooling season, the heating season, the transitional spring and the transitional autumn. Meanwhile, the exergy loss and energy consumption are analyzed for the new system in four seasons through simulation. The results show that in the cooling and heating seasons, the exergy loss first decreases and then increases with the increase of spray power (SP) and mass flow rate of circulating water (MFRW). In the transition season, the exergy loss decreases with the increase of MFRW, while it first decreases and then increases with the increase of SP. However, the annual energy consumption increases with the increase of SP and MFRW. Aim at the minimum exergy loss of new system, its optimal control parameters are obtained in four seasons through optimization. Specifically, when the mass flow rate of supply air is the minimum ventilation rate required by sows, the optimal SP and MFRW are recommended as 40 kW and 12245 kg/h in the cooling and heating seasons, respectively. Meanwhile, they are recommended as 35 kW and 12245 kg/h in the transition season, respectively. The above research can provide guidance for the improvement of traditional spray cooling systems and the performance optimization of new system.
引用
收藏
页数:16
相关论文
共 50 条
  • [1] Performance and optimization of a new spray cooling system with PV/T and heat recovery in sow houses: A case study in Nanchang, China
    Ma, Hongqiang
    Xie, Yue
    Min, Kai
    Liu, Yu
    Wang, Shengxun
    Ding, Ruixiang
    Luo, Xinmei
    APPLIED THERMAL ENGINEERING, 2023, 232
  • [2] Investigation on the control strategy of new spray cooling system based on PV/T and heat recovery in sow houses: As a case study in Nanchang, China
    Ma, Hongqiang
    Xie, Yue
    Min, Kai
    Chen, Yufei
    Liu, Yu
    Wang, Shengxun
    Ding, Ruixiang
    Cai, Weihua
    RENEWABLE ENERGY, 2023, 219
  • [3] Comparison of operation characteristics of a new spray cooling system based on PV/T and heat recovery in sow houses in five climate regions of China
    Ma, Hongqiang
    Xie, Yue
    Wang, Shengxun
    Min, Kai
    Luo, Xinmei
    Cai, Weihua
    ENERGY AND BUILDINGS, 2023, 296
  • [4] Energy and exergy analysis and optimization of a novel heating, cooling, and electricity generation system composed of PV/T-heat pipe system and thermal wheel
    Shahsavar, Amin
    Arici, Muslum
    RENEWABLE ENERGY, 2023, 203 : 394 - 406
  • [5] APPLICATION OF EXERGY ANALYSIS TO THE DESIGN OF A WASTE HEAT RECOVERY SYSTEM FOR COAL GASIFICATION.
    Nitschke, Eberhard
    ACS Symposium Series, 1983, : 147 - 159
  • [6] Application of Exergy Analysis in Flue Gas Condensation Waste Heat Recovery System Evaluation
    Zhang, Le
    Zhai, Huixing
    He, Jiayuan
    Yang, Fan
    Wang, Suilin
    ENERGIES, 2022, 15 (20)
  • [7] APPLICATION OF EXERGY ANALYSIS TO THE DESIGN OF A WASTE HEAT-RECOVERY SYSTEM FOR COAL-GASIFICATION
    NITSCHKE, E
    ACS SYMPOSIUM SERIES, 1983, 235 : 147 - 159
  • [8] Presentation of two new two-stage desiccant cooling cycles based on heat recovery and evaluation of performance based on energy and exergy analysis
    Tavakol, Peyman
    Behbahaninia, Ali
    JOURNAL OF BUILDING ENGINEERING, 2018, 20 : 455 - 466
  • [9] Selection of a waste heat recovery system for a marine diesel engine based on Exergy analysis
    Ahmed, Salman Abdu
    Zhou, Song
    Orji, Malachy
    INTERNATIONAL JOURNAL OF ENGINEERING RESEARCH IN AFRICA, 2016, 25 : 36 - 51
  • [10] Performance and application boundary analysis of a solar PV/T heat pump system
    Han, Yuhang
    Feng, Lejun
    Fu, Zhihao
    Sui, Jun
    SUSTAINABLE ENERGY & FUELS, 2024, 8 (11) : 2451 - 2460