Optomechanical assessment of photorefractive corneal cross-linking via optical coherence elastography

被引:2
|
作者
Frigelli, Matteo [1 ]
Buchler, Philippe [1 ]
Kling, Sabine [1 ,2 ]
机构
[1] Univ Bern, ARTORG Ctr Biomed Engn Res, Computat Bioengn Grp, Bern, Switzerland
[2] Swiss Fed Inst Technol, Inst Biomed Engn, ITET Dept, Zurich, Switzerland
基金
瑞士国家科学基金会;
关键词
optical coherence elastography; corneal cross-linking; optomechanical changes; accelerated CXL; ambient pressure modulation; corneal biomechanics. (Min.5-Max. 8; BRILLOUIN MICROSCOPY; DEFORMATION; BIOMECHANICS; KERATOCONUS; NONCONTACT; STRAIN; PROBE; OCT;
D O I
10.3389/fbioe.2023.1272097
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Purpose: Corneal cross-linking (CXL) has recently been used with promising results to positively affect corneal refractive power in the treatment of hyperopia and mild myopia. However, understanding and predicting the optomechanical changes induced by this procedure are challenging.Methods: We applied ambient pressure modulation based optical coherence elastography (OCE) to quantify the refractive and mechanical effects of patterned CXL and their relationship to energy delivered during the treatment on porcine corneas. Three different patterned treatments were performed, designed according to Zernike polynomial functions (circle, astigmatism, coma). In addition, three different irradiation protocols were analyzed: standard Dresden CXL (fluence of 5.4 J/cm(2)), accelerated CXL (fluence of 5.4 J/cm(2)), and high-fluence CXL (fluence of 16.2 J/cm(2)). The axial strain distribution in the stroma induced by ocular inflation (Delta p = 30 mmHg) was quantified, maps of the anterior sagittal curvature were constructed and cylindrical refraction was assessed.Results: Thirty minutes after CXL, there was a statistically significant increase in axial strain amplitude (p < 0.050) and a reduction in sagittal curvature (p < 0.050) in the regions treated with all irradiation patterns compared to the non-irradiated ones. Thirty-6 hours later, the non-irradiated regions showed compressive strains, while the axial strain in the CXL-treated regions was close to zero, and the reduction in sagittal curvature observed 30 minutes after the treatment was maintained. The Dresden CXL and accelerated CXL produced comparable amounts of stiffening and refractive changes (p = 0.856), while high-fluence CXL produced the strongest response in terms of axial strain (6.9 parts per thousand +/- 1.9 parts per thousand) and refractive correction (3.4 +/- 0.9 D). Tripling the energy administered during CXL resulted in a 2.4-fold increase in the resulting refractive correction.Conclusion: OCE showed that refractive changes and alterations in corneal biomechanics are directly related. A patient-specific selection of both, the administered UV fluence and the irradiation pattern during CXL is promising to allow customized photorefractive corrections in the future.
引用
收藏
页数:13
相关论文
共 50 条
  • [41] Supersonic Shear Wave Elastography for the In Vivo Evaluation of Transepithelial Corneal Collagen Cross-Linking
    Touboul, David
    Gennisson, Jean-Luc
    Nguyen, Thu-Mai
    Robinet, Antoine
    Roberts, Cynthia J.
    Tanter, Mickael
    Grenier, Nicolas
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2014, 55 (03) : 1976 - 1984
  • [42] In-vivo Assessment of Corneal Biomechanics using Optical Coherence Elastography
    De Stefano, Vinicius Silbiger
    Ford, Matthew R.
    Seven, Ibrahim
    Hughes, Brent
    Dupps, William J.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2017, 58 (08)
  • [43] Assessment of corneal viscoelasticity using elastic wave optical coherence elastography
    Jin, Zi
    Zhou, Yuheng
    Shen, Meixiao
    Wang, Yuanyuan
    Lu, Fan
    Zhu, Dexi
    JOURNAL OF BIOPHOTONICS, 2020, 13 (01)
  • [44] Quantitative Assessment of UVA-Riboflavin Corneal Cross-Linking Using Nonlinear Optical Microscopy
    Chai, Dongyul
    Gaster, Ronald N.
    Roizenblatt, Roberto
    Juhasz, Tibor
    Brown, Donald J.
    Jester, James V.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2011, 52 (07) : 4231 - 4238
  • [45] CORNEAL CROSS-LINKING AT SYDNEY EYE HOSPITAL: PILOT EVALUATION OF THE FIGHT CORNEAL BLINDNESS MODULE FOR CORNEAL CROSS-LINKING
    Watson, Stephanie
    Go, Christopher
    Gunasekara, Gayani
    Herrera-Bond, Amparo
    Kerdraon, Yves
    Males, John
    CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2015, 43 : 86 - 86
  • [46] Optical coherence elastography by ambient pressure modulation for high-resolution strain mapping applied to patterned cross-linking
    Kling, Sabine
    JOURNAL OF THE ROYAL SOCIETY INTERFACE, 2020, 17 (162)
  • [47] Evaluation of the Corneal Collagen Cross-Linking Demarcation Line Profile Using Anterior Segment Optical Coherence Tomography
    Kymionis, George D.
    Grentzelos, Michael A.
    Plaka, Argyro D.
    Stojanovic, Nela
    Tsoulnaras, Konstantinos I.
    Mikropoulos, Dimitrios G.
    Rallis, Konstantinos I.
    Kankariya, Vardhaman P.
    CORNEA, 2013, 32 (07) : 907 - 910
  • [48] Automated Detection and Classification of Corneal Haze Using Optical Coherence Tomography in Patients With Keratoconus After Cross-Linking
    Dhaini, Ahmad R.
    Fattah, Maamoun Abdul
    El-Oud, Sara Maria
    Awwad, Shady T.
    CORNEA, 2018, 37 (07) : 863 - 869
  • [49] Collagen cross-linking and corneal infections
    Tayapad, Joanne B.
    Viguilla, Aileen Q.
    Reyes, Johann M. G.
    CURRENT OPINION IN OPHTHALMOLOGY, 2013, 24 (04) : 288 - 290
  • [50] Corneal Cross-Linking: Epi-On
    Hafezi, Farhad
    CORNEA, 2022, 41 (10) : 1203 - 1204