The Lifetime Prediction and Insulation Failure Mechanism of XLPE for High-Voltage Cable

被引:7
|
作者
Li, Guochang [1 ,2 ]
Wang, Zhaochen [2 ]
Lan, Rui [2 ]
Wei, Yanhui [2 ]
Nie, Yongjie [3 ]
Li, Shengtao [4 ]
Lei, Qingquan [2 ]
机构
[1] Xi An Jiao Tong Univ, Xian 710049, Peoples R China
[2] Qingdao Univ Sci & Technol, Inst Adv Elect Mat, Qingdao 266042, Peoples R China
[3] Yunnan Power Gird Co Ltd, Elect Power Res Inst, Kunming 650217, Yunnan, Peoples R China
[4] Xi An Jiao Tong Univ, State Key Lab Elect Insulat & Power Equipment, Xian 710049, Peoples R China
基金
中国国家自然科学基金;
关键词
~Failure mechanism; life prediction; thermal aging; cross-linked polyethylene (XLPE) high voltage cable;
D O I
10.1109/TDEI.2022.3215605
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The performance parameters and service life of the insulation layer of high-voltage cables are the key to ensure safe cable operation. Through extracting the mechanical parameters of high voltage cable insulation layer under different thermal aging temperatures, a normal linear regression model is established to predict the service life of high voltage cables. Meanwhile, the physicochemical characteristics such as microscopic morphology and molecular structure changes of the cable insulation layer are analyzed, the dielectric properties and breakdown field strength under ac condition are tested and themacroscopic electrical properties of the insulation layer are studied, and the insulation failure mechanism is further analyzed. The experimental results show that the elongation at break retention rate of cross-linkedpolyethylene (XLPE) increases slowly with the aging time, and then decreases rapidly when it reaches 50% of the initial elongation at break retention rate. The normal linear regression prediction model is established based on the Arrhenius formula, and it can be obtained the life endpoint of XLPE high voltage cable about 65 years at an operating temperature of 70 degrees C. Further analysis, under the action of heat and oxygen, the crystal zone structure of cable insulation is seriouslydamaged, and the carbonyl index is significantly increased. Accordingly, when the aging failure point is reached, the dielectric permittivity and dielectric loss of insulation are significantly increased, and the breakdown performance is significantly decreased. The work has an important guiding significance for insulation condition assessment and life prediction of high voltage cable.
引用
收藏
页码:761 / 768
页数:8
相关论文
共 50 条
  • [21] THE EFFECT OF MORPHOLOGY ON THE IMPULSE VOLTAGE BREAKDOWN IN XLPE CABLE INSULATION
    FUKUDA, T
    IRIE, S
    ASADA, Y
    MAEDA, M
    NAKAGAWA, H
    YAMADA, N
    [J]. IEEE TRANSACTIONS ON ELECTRICAL INSULATION, 1982, 17 (05): : 386 - 391
  • [22] Impulse breakdown superposed on ac voltage in XLPE cable insulation
    Murata, Y
    Katakai, S
    Kanaoka, M
    [J]. IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 1996, 3 (03) : 361 - 365
  • [23] A Multivariable Aging Model for Estimating Residual Lifetime of XLPE Cable Insulation
    Kim, Chonung
    Huang, Xingyi
    Jiang, Pingkai
    Liu, Fei
    Wang, Genlin
    Zhang, Jun
    [J]. ICPADM 2009: PROCEEDINGS OF THE 9TH INTERNATIONAL CONFERENCE ON PROPERTIES AND APPLICATIONS OF DIELECTRIC MATERIALS, VOLS 1-3, 2009, : 281 - 284
  • [24] Electrical tree degradation in high-voltage cable insulation: progress and challenges
    Su, Jingang
    Du, Boxue
    Li, Jin
    Li, Zhonglei
    [J]. HIGH VOLTAGE, 2020, 5 (04): : 353 - 364
  • [25] The influence of water in XLPE cable conductor on XLPE insulation breakdown voltage and partial discharge
    Nikolajevic, SV
    STojanovic, BB
    [J]. CONFERENCE RECORD OF THE 1996 IEEE INTERNATIONAL SYMPOSIUM ON ELECTRICAL INSULATION, VOLS 1 AND 2, 1996, : 604 - 607
  • [26] High-Voltage FDS of Thermally Aged XLPE Cable and Its Correlation with Physicochemical Properties
    Wang, Haoyue
    Sun, Maolun
    Zhao, Kaijie
    Wang, Xiaowei
    Xu, Qilong
    Wang, Wei
    Li, Chengrong
    [J]. POLYMERS, 2022, 14 (17)
  • [27] NEW HIGH-VOLTAGE XLPE CABLE CURING PROCESS-DEVELOPMENT AND ELECTRICAL CHARACTERISTICS
    YAMAUCHI, H
    KANEKO, R
    OKADA, M
    OTSUJI, M
    MATSUI, M
    SUGIYAMA, K
    [J]. IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1977, 96 (04): : 1062 - 1062
  • [28] Water Ingress in High-Voltage Cross-Linked Polyethylene (XLPE) Cable Terminations
    Mauseth, Frank
    Hvidsten, Sverre
    Birkenes, Geir
    [J]. IEEE ELECTRICAL INSULATION MAGAZINE, 2012, 28 (05) : 24 - 31
  • [29] Dynamic Thermal Analysis of High-Voltage Power Cable Insulation for Cable Dynamic Thermal Rating
    Wang, Peng-Yu
    Ma, Hui
    Liu, Gang
    Han, Zhuo-Zhan
    Guo, De-Ming
    Xu, Tao
    Kang, Long-Yun
    [J]. IEEE ACCESS, 2019, 7 : 56095 - 56106
  • [30] Insulation Characteristics and Failure Mechanism of High-Voltage Cables under Different Thermal Aging Temperatures
    Duan, Yubing
    Han, Mingming
    Wang, Zhaochen
    Lan, Rui
    Li, Guochang
    [J]. Diangong Jishu Xuebao/Transactions of China Electrotechnical Society, 2024, 39 (01): : 45 - 54