Dynamic simulation study of the secondary frequency regulation of a 1000 MW thermal power unit assisted by flywheel energy storage

被引:0
|
作者
Lv, Zhijia [1 ]
Liu, Xiaolong [1 ]
Liu, Zhongwen [2 ]
Jiang, Zhicheng [1 ]
Lin, Zhao [1 ]
Zhao, Zicheng [1 ]
Han, Xu [2 ]
机构
[1] CHN Energy Lianjiang Port & Power Co Ltd, Fuzhou 350500, Peoples R China
[2] North China Elect Power Univ, Hebei Key Lab Low Carbon & High Efficiency Power G, Baoding 071003, Hebei, Peoples R China
关键词
525.7 Energy Storage - 601.1 Mechanical Devices - 601.2 Machine Components - 614 Steam Power Plants - 617.2 Steam Turbines - 704.1 Electric Components - 706.1 Electric Power Systems - 723.5 Computer Applications - 731.2 Control System Applications - 921 Mathematics;
D O I
10.1063/5.0149947
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
The rapid development of new energy sources has brought a certain impact on the original power grid structure, accelerated the wear of unit equipment, and affected the stability, safety, and economy of thermal power unit operation, so it is proposed to add an energy storage system to solve the above problems. To analyze the secondary frequency regulation effect of thermal power units assisted by a flywheel energy storage system, a mathematical model of the control strategy on both sides of the boiler, steam turbine, and flywheel permanent magnet synchronous motor is proposed, and a two-regional power grid model is built through MATLAB/Simulink to simulate the frequency regulation effect of units with or without energy storage participation through step disturbance and continuous disturbance, which are 0.045 and 0.023 p.u. MW. Under step disturbance, the frequency fluctuation of the coupled energy storage system changed by 0.025 228 p.u. Hz, the time for the system to return to a steady state was shortened by 5.85 s, the maximum change of the frequency of the system in Region 2 was reduced by 0.025 579 p.u. Hz, and under continuous disturbance, the fluctuation of the output power of the steam turbine in Region 1 was reduced by 0.022 982 p.u. MW. In summary, under the same disturbance conditions in the outside world, the use of flywheel energy storage to assist the frequency regulation of thermal power units can effectively reduce the frequency fluctuation of the system, reduce the fluctuation of the output power of the steam turbine, reduce the loss of mechanical equipment, and extend the service life of the unit to a certain extent.
引用
收藏
页数:14
相关论文
共 50 条
  • [21] Thermal power-flywheel energy storage combined frequency modulation system participates in primary frequency modulation technology of power grid
    Li Jie
    Meng Gaojun
    Ding Pengfei
    Sun Yukun
    Qian Congcong
    Zhang Jing
    2022 25TH INTERNATIONAL CONFERENCE ON ELECTRICAL MACHINES AND SYSTEMS (ICEMS 2022), 2022,
  • [22] Linear parabolic trough solar power plant assisted with latent thermal energy storage system: A dynamic simulation
    Mosleh, Hassan Jafari
    Ahmadi, Rouhollah
    APPLIED THERMAL ENGINEERING, 2019, 161
  • [23] Comparison of Dynamic Models of Battery Energy Storage for Frequency Regulation in Power System
    Adrees, Atia
    Andami, Hooman
    Milanovic, Jovica V.
    PROCEEDINGS OF THE 18TH MEDITERRANEAN ELECTROTECHNICAL CONFERENCE MELECON 2016, 2016,
  • [24] Power Hardware-in-the-Loop Simulation Study on Frequency Regulation Through Direct Load Control of Thermal and Electrical Energy Storage Resources
    Kim, Young-Jin
    Wang, Jianhui
    IEEE TRANSACTIONS ON SMART GRID, 2018, 9 (04) : 2786 - 2796
  • [25] Dynamic simulation on the frequency regulation ability enhancement with energy stored in steam distribution system for a combined heat and power unit
    Tang, Haiyu
    Liu, Ming
    Zhang, Shunqi
    Wang, Na
    Wang, Chaoyang
    Ma, Guofeng
    Yan, Junjie
    JOURNAL OF ENERGY STORAGE, 2024, 84
  • [26] Dynamic simulation on the frequency regulation ability enhancement with energy stored in steam distribution system for a combined heat and power unit
    Tang, Haiyu
    Liu, Ming
    Zhang, Shunqi
    Wang, Na
    Wang, Chaoyang
    Ma, Guofeng
    Yan, Junjie
    Journal of Energy Storage, 2024, 84
  • [27] Optimization strategy of secondary frequency modulation based on dynamic loss model of the energy storage unit
    Li, Cuiping
    Li, Jing
    Li, Junhui
    Zhang, Xiaochi
    Hou, Tao
    JOURNAL OF ENERGY STORAGE, 2022, 51
  • [28] Coordinated Control Strategy and Optimal Capacity Configuration for Flywheel Energy Storage Participating in Primary Frequency Regulation of Power Grid
    Luo Y.
    Tian L.
    Wang Y.
    Li J.
    Li J.
    Jiang T.
    Dianli Xitong Zidonghua/Automation of Electric Power Systems, 2022, 46 (09): : 71 - 82
  • [29] Simulation of Wind Power System Involving Flywheel Energy Storage Unit Based on Wind Speed Forecasting by RBF Neural Network
    Feng, Yi
    Lin, Heyun
    Yan, Jianhu
    Lu, Xiaoquan
    Yang, Hui
    2013 INTERNATIONAL CONFERENCE ON RENEWABLE ENERGY RESEARCH AND APPLICATIONS (ICRERA), 2013, : 763 - 768
  • [30] An integrated thermal power-energy storage system for improving primary frequency regulation performance of thermal power units
    Gao S.
    Li J.
    Song H.
    Ding L.
    Zhang C.
    Dianli Xitong Baohu yu Kongzhi/Power System Protection and Control, 2023, 51 (21): : 116 - 125