The Relationship between the Contouring Time of the Metal Artifacts Area and Metal Artifacts in Head and Neck Radiotherapy

被引:2
|
作者
Katsura, Kouji [1 ,2 ,3 ]
Tanabe, Satoshi [4 ]
Nakano, Hisashi [4 ]
Sakai, Madoka [5 ]
Ohta, Atsushi [5 ]
Kaidu, Motoki [5 ]
Soga, Marie [1 ]
Kobayashi, Taichi [2 ,3 ]
Takamura, Masaki [2 ,3 ]
Hayashi, Takafumi [1 ,2 ,3 ]
机构
[1] Niigata Univ Med & Dent Hosp, Dept Oral Radiol, Niigata 9518520, Japan
[2] Niigata Univ, Fac Dent, Div Oral & Maxillofacial Radiol, Niigata 9518514, Japan
[3] Niigata Univ, Grad Sch Med & Dent Sci, Niigata 9518514, Japan
[4] Niigata Univ Med & Dent Hosp, Div Radiat Oncol, Niigata 8518520, Japan
[5] Niigata Univ, Grad Sch Med & Dent Sci, Dept Radiol & Radiat Oncol, Niigata 9518514, Japan
关键词
metal artifacts; metallic dental restorations; contouring workload; head and neck radiotherapy; DOSE CALCULATION; IMPACT;
D O I
10.3390/tomography9010009
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
(1) Background: The impacts of metal artifacts (MAs) on the contouring workload for head and neck radiotherapy have not yet been clarified. Therefore, this study evaluated the relationship between the contouring time of the MAs area and MAs on head and neck radiotherapy treatment planning. (2) Methods: We used treatment planning computed tomography (CT) images for head and neck radiotherapy. MAs were classified into three severities by the percentage of CT images containing MAs: mild (<25%), moderate (25-75%), and severe (>75%). We randomly selected nine patients to evaluate the relationship between MAs and the contouring time of the MAs area. (3) Results: The contouring time of MAs showed moderate positive correlations with the MAs volume and the number of CT images containing MAs. Interobserver reliability of the extracted MAs volume and contouring time were excellent and poor, respectively. (4) Conclusions: Our study suggests that the contouring time of MAs areas is related to individual commitment rather than clinical experience. Therefore, the development of software combining metal artifact reduction methods with automatic contouring methods is necessary to reducing interobserver variability and contouring workload.
引用
收藏
页码:98 / 104
页数:7
相关论文
共 50 条
  • [21] URARTIAN METAL ARTIFACTS: AN ARCHAEOLOGICAL REVIEW
    Muscarella, Oscar White
    ANCIENT CIVILIZATIONS FROM SCYTHIA TO SIBERIA, 2006, 12 (1-2) : 147 - 177
  • [22] Neural Network Performance Evaluation of Simulated and Genuine Head-and-Neck Computed Tomography Images to Reduce Metal Artifacts
    Khaleghi, Goli
    Hosntalab, Mohammad
    Sadeghi, Mahdi
    Reiazi, Reza
    Mahdavi, Seied
    JOURNAL OF MEDICAL SIGNALS & SENSORS, 2022, 12 (04): : 269 - +
  • [23] A Comparison of Interpolation Methods in Head and Neck Radiotherapy Contouring
    Spencer, J.
    Chen, K.
    Boukerroui, D.
    Gooding, M.
    Fenwick, J.
    MEDICAL PHYSICS, 2018, 45 (06) : E193 - E193
  • [24] The effects of the orthopedic metal artifact reduction (O-MAR) algorithm on contouring and dosimetry of head and neck radiotherapy patients
    Sillanpaa, Jussi
    Lovelock, Michael
    Mueller, Boris
    MEDICAL DOSIMETRY, 2020, 45 (01) : 92 - 96
  • [25] The retouching on archaeological metal artifacts: reflections and proposals, between theory and practice
    Basilissi, Vilma
    Pannuzi, Simona
    Rivaroli, Laura
    GE-CONSERVACION, 2020, (18): : 356 - 361
  • [26] Evaluation of Using CT Gantry Tilt Scan on Head and Neck Patients With Dental Structure - Scans Show Less Metal Artifacts
    Lee, C.
    EUROPEAN JOURNAL OF CANCER, 2011, 47 : S566 - S567
  • [27] The influence of metal artifacts on navigation and the reduction of artifacts by the use of polyether-ether-ketone
    Citak, M.
    Kendoff, D.
    Wanich, T.
    Look, V.
    Stueber, V.
    Geerling, J.
    Krettek, C.
    Huefner, T.
    COMPUTER AIDED SURGERY, 2008, 13 (04) : 233 - 239
  • [28] MR Imaging Artifacts in the Head and Neck Region Pitfalls and Solutions
    Marshall, Emily L.
    Ginat, Daniel T.
    Sammet, Steffen
    NEUROIMAGING CLINICS OF NORTH AMERICA, 2022, 32 (02) : 279 - 286
  • [29] PROVENANCE DETERMINATION OF METAL ARTIFACTS - METHODOLOGICAL CONSIDERATIONS
    PERNICKA, E
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1986, 14 (01): : 24 - 29
  • [30] REMOVAL OF METAL CLIP ARTIFACTS IN CT RECONSTRUCTIONS
    GLOVER, GH
    PELC, NJ
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1980, 4 (05) : 714 - 715