A Novel Technique for Autograft Preparation Using Patient-Specific Instrumentation (PSI) Assistance in Total Hip Arthroplasty in Developmental Dysplasia of Hip (DDH)

被引:1
|
作者
Lin, Chun-Ru [1 ]
Chou, Hsuan [2 ]
Luo, Chu-An [3 ]
Chang, Shu-Hao [2 ,4 ]
机构
[1] Chang Gung Mem Hosp, Dept Med Educ, Linkou Branch, 5 Fuxing St, Taoyuan City 333423, Taiwan
[2] Fu Jen Catholic Univ, Coll Med, Sch Med, 510 Zhongzheng Rd, New Taipei City 24205, Taiwan
[3] Plus Biotechnol Co Ltd, Dept Precis Surg Dev, 6F,23 Qiaohe Rd, New Taipei City 23529, Taiwan
[4] Fu Jen Catholic Univ, Fu Jen Catholic Univ Hosp, Dept Orthoped, 69 Guizi Rd, New Taipei City 24352, Taiwan
来源
JOURNAL OF PERSONALIZED MEDICINE | 2023年 / 13卷 / 09期
关键词
patient-specific instrumentation; developmental dysplasia of hip; total hip arthroplasty; peri-operative outcome; improved complication rate; TOTAL KNEE ARTHROPLASTY; RISK-FACTORS; MANAGEMENT; COMPLICATIONS; REPLACEMENT; DISLOCATION; DIAGNOSIS; ACCURACY; UPDATE; BLOOD;
D O I
10.3390/jpm13091331
中图分类号
R19 [保健组织与事业(卫生事业管理)];
学科分类号
摘要
Due to the change in the structure of the proximal femur and acetabulum in patients with developmental dysplasia of the hip, total hip arthroplasty (THA) was difficult to perform for surgeons. To elevate the acetabular coverage rate, we developed a technique in the use of a patient-specific instrumentation (PSI) graft in patients with developmental dysplasia of hip (DDH) undergoing surgery. This study aims to evaluate the peri-operative outcomes of THA with PSI graft in patients with DDH. This study recruited 6 patients suffering from Crowe I DDH with secondary Grade IV osteoarthritis. All the patients underwent THA with PSI graft performed by a well-experienced surgeon. Perioperative outcomes included surgical procedures, blood loss during operation, the volume of blood transfusion, length of hospitalization, complications, and the mean difference in hemoglobin levels before and after surgery. All the outcomes analyzed were assessed by mean and standard deviation. The average duration of the surgical procedure was found to be 221.17 min, with an SD of 19.65 min. The mean blood loss during the operation was 733.33 mL, with an SD of 355.90 mL. The mean length of hospital stay was calculated to be 6 days, with an SD of 0.89 days. Furthermore, the mean difference between the pre- and postoperative hemoglobin levels was 2.15, with an SD of 0.99. A total of three patients received 2 units of leukocyte-poor red blood cells (LPR) as an accepted blood transfusion. There were no reported complications observed during the admission and one month after the operation. This study reported the peri-operative outcomes in the patients with DDH who underwent THA with PSI graft. We found that THA with PSI graft would provide a safe procedure without significant complications. We assumed that the PSI graft in THA may increase the coverage rate of the acetabulum, which may increase the graft union rates. Further cohort studies and randomized controlled trials were needed to confirm our findings.
引用
收藏
页数:11
相关论文
共 50 条
  • [31] Patient-specific mobility assessment to monitor recovery after total hip arthroplasty
    Gargiulo, Paolo
    Edmunds, Kyle Joseph
    Gislason, Magnus K.
    Latour, Chase
    Hermannsson, Thostur
    Esposito, Luca
    Bifulco, Paolo
    Cesarelli, Mario
    Fraldi, Massimiliano
    Cristofolini, Luca
    Jonsson, Halldor, Jr.
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2018, 232 (10) : 1048 - 1059
  • [32] Accuracy and Reproducibility Using Patient-Specific Instrumentation in Total Ankle Arthroplasty
    Daigre, Justin
    Berlet, Gregory
    Van Dyke, Bryan
    Peterson, Kyle S.
    Santrock, Robert
    FOOT & ANKLE INTERNATIONAL, 2017, 38 (04) : 412 - 418
  • [33] Novel alignment measurement technique for total knee arthroplasty using patient specific instrumentation
    Kazumasa Yamamura
    Yukihide Minoda
    Shigekazu Mizokawa
    Yoichi Ohta
    Ryo Sugama
    Suguru Nakamura
    Hideki Ueyama
    Hiroaki Nakamura
    Archives of Orthopaedic and Trauma Surgery, 2017, 137 : 401 - 407
  • [34] Novel alignment measurement technique for total knee arthroplasty using patient specific instrumentation
    Yamamura, Kazumasa
    Minoda, Yukihide
    Mizokawa, Shigekazu
    Ohta, Yoichi
    Sugama, Ryo
    Nakamura, Suguru
    Ueyama, Hideki
    Nakamura, Hiroaki
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2017, 137 (03) : 401 - 407
  • [35] Primary Staged Bilateral Total Hip Arthroplasty in a Patient With Short Stature and Hartofilakidis Type I Developmental Dysplasia of the Hip
    Milonakis, Nikolaos
    Douvlis, Georgios
    Tsiridis, Christothea-Alexandra
    Gamie, Zakareya
    Kenanidis, Eustathios
    Tsiridis, Eleftherios
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2024, 16 (01)
  • [36] Implant survival and patient-reported outcomes after total hip arthroplasty in young patients with developmental dysplasia of the hip
    Swarup, Ishaan
    Marshall, Astrid C.
    Lee, Yuo-yu
    Figgie, Mark P.
    HIP INTERNATIONAL, 2016, 26 (04) : 367 - 373
  • [37] Total hip arthroplasty for crowe type IV developmental dysplasia of the hip using a dual mobility acetabular cup
    Ukaj, Skender
    Krasniqi, Shaip
    Ukaj, Dren
    Dervishaj, Fatime
    Dyla, Dea
    Mucaj, Sefedin
    Tahirbegolli, Bernard
    SCIENTIFIC REPORTS, 2025, 15 (01):
  • [38] Cementless total hip arthroplasty using custom stem and reinforcement ring in hip osteoarthritis following developmental dysplasia
    Flecher, X.
    Parratte, S.
    Aubaniac, J. M.
    Argenson, J. N.
    HIP INTERNATIONAL, 2007, 17 (02) : S120 - S127
  • [39] Four-dimensional patient-specific musculoskeletal model of the patient after Total Hip Arthroplasty
    Otake, Y
    Suzuki, N
    Hattori, A
    Miki, H
    Yamamura, M
    Nakamura, N
    Sugano, N
    Yonenobu, K
    Ochi, T
    CARS 2004: COMPUTER ASSISTED RADIOLOGY AND SURGERY, PROCEEDINGS, 2004, 1268 : 591 - 596
  • [40] The reliability and validity of the self-reported patient-specific index for total hip arthroplasty
    Wright, JG
    Young, NL
    Waddell, JP
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2000, 82A (06): : 829 - 837