Temperature-Tuning Desorption Ionization for Ambient Mass Spectrometry

被引:5
|
作者
Li, Ningxi [1 ]
Cai, Zhijun [1 ]
Zhang, Zhongyao [1 ]
Zhang, Wenpeng [1 ]
Ma, Xiaoxiao [1 ]
Zhou, Xiaoyu [1 ]
Ouyang, Zheng [1 ]
机构
[1] Tsinghua Univ, Dept Precis Instrument, State Key Lab Precis Measurement Technol & Instrum, Beijing 100084, Peoples R China
基金
中国国家自然科学基金;
关键词
PAPER SPRAY;
D O I
10.1021/acs.analchem.3c01942
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In the past decade, mass spectrometry (MS) has been widelyusedfor a broad range of on-site applications. This is largely attributedto the rapid advancement of technologies, such as ambient ionizationand mass spectrometer miniaturization. Here, we report the developmentof the temperature-tuning desorption ionization (TTDI) method forversatile on-site applications using a miniature MS system. A uniquefeature of TTDI is its dynamic temperature range applicable from 30to 800 & DEG;C, which enables optimal desorption ionization appliedfor chemical and biological compounds through tuning the temperatureat the sampling spot. The versatility of TTDI has been demonstratedthrough on-site MS analysis of a variety of samples, such as explosiveson surfaces, drugs of abuse in biofluids, and screening biomarkersin tissues.
引用
收藏
页码:11099 / 11105
页数:7
相关论文
共 50 条
  • [11] Chemometric optimization of a low-temperature plasma source design for ambient desorption/ionization mass spectrometry
    Albert, Anastasia
    Engelhard, Carsten
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2015, 105 : 109 - 115
  • [12] Ambient Ionization Mass Spectrometry
    Huang, Min-Zong
    Yuan, Cheng-Hui
    Cheng, Sy-Chyi
    Cho, Yi-Tzu
    Shiea, Jentaie
    ANNUAL REVIEW OF ANALYTICAL CHEMISTRY, VOL 3, 2010, 3 : 43 - 65
  • [13] Ambient ionization mass spectrometry
    Lebedev, A. T.
    RUSSIAN CHEMICAL REVIEWS, 2015, 84 (07) : 665 - 692
  • [14] Microfabricated Glow Discharge Plasma (MFGDP) for Ambient Desorption/Ionization Mass Spectrometry
    Ding, Xuelu
    Zhan, Xuefang
    Yuan, Xin
    Zhao, Zhongjun
    Duan, Yixiang
    ANALYTICAL CHEMISTRY, 2013, 85 (19) : 9013 - 9020
  • [15] Ambient (desorption/ionization) mass spectrometry methods for pesticide testing in food: a review
    Beneito-Cambra, Miriam
    Gilbert-Lopez, Bienvenida
    Moreno-Gonzalez, David
    Bouza, Marcos
    Franzke, Joachim
    Garcia-Reyes, Juan F.
    Molina-Diaz, Antonio
    ANALYTICAL METHODS, 2020, 12 (40) : 4831 - 4852
  • [16] Ambient Mass Spectrometry Imaging: A Comparison of Desorption Ionization by Sonic Spray and Electrospray
    Janfelt, Christian
    Norgaard, Asger W.
    JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2012, 23 (10) : 1670 - 1678
  • [17] Microwave-Induced Plasma Desorption/Ionization Source for Ambient Mass Spectrometry
    Zhan, Xuefang
    Zhao, Zhongjun
    Yuan, Xin
    Wang, Qihui
    Li, Dandan
    Xie, Hong
    Li, Xuemei
    Zhou, Meigui
    Duan, Yixiang
    ANALYTICAL CHEMISTRY, 2013, 85 (09) : 4512 - 4519
  • [18] Ambient Pressure Desorption Ionization Mass Spectrometry in Support of Preclinical Pharmaceutical Development
    Helmy, Roy
    Schafer, Wes
    Buhler, Leah
    Marcinko, Stephen
    Musselman, Brian
    Guidry, Erin
    Jenkins, Herb
    Fleitz, Fred
    Welch, Christopher J.
    ORGANIC PROCESS RESEARCH & DEVELOPMENT, 2010, 14 (02) : 386 - 392
  • [19] Ambient Mass Spectrometry Imaging: Plasma Assisted Laser Desorption Ionization Mass Spectrometry Imaging and Its Applications
    Feng, Baosheng
    Zhang, Jialing
    Chang, Cuilan
    Li, Liping
    Li, Min
    Xiong, Xingchuang
    Guo, Chengan
    Tang, Fei
    Bai, Yu
    Liu, Huwei
    ANALYTICAL CHEMISTRY, 2014, 86 (09) : 4164 - 4169
  • [20] DESORPTION IONIZATION MASS-SPECTROMETRY
    BUSCH, KL
    JOURNAL OF MASS SPECTROMETRY, 1995, 30 (02): : 233 - 240