High Spatial-Resolution Skull Base Imaging With Photon-Counting Computed Tomography and Energy-Integrating Computed Tomography: A Comparative Phantom Study

被引:4
|
作者
Rajagopal, Jayasai R. [1 ,2 ]
Schwartz, Fides R. [3 ]
Solomon, Justin B. [1 ]
Enterline, David S. [3 ]
Samei, Ehsan [1 ,4 ]
机构
[1] Duke Univ Med Ctr, Dept Radiol, Med Phys Grad Program, Carl E Ravin Adv Imaging Labs, Durham, NC USA
[2] NIH, Clin Ctr, Radiol & Imaging Sci, Bethesda, MD USA
[3] Duke Univ Med Ctr, Duke Univ Hlth Syst, Dept Radiol, Durham, NC USA
[4] Carl E Ravin Adv Imaging Labs, Hock Plaza,Suite 302,2424 Erwin Rd, Durham, NC 27710 USA
基金
美国国家卫生研究院;
关键词
computed tomography; high-resolution; photon-counting; skull base; CT; SYSTEM; RECONSTRUCTION; HEIGHT; NOISE;
D O I
10.1097/RCT.0000000000001464
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Photon-counting computed tomography (PCCT) offers better high-resolution and noise performance than energy integrating detector (EID) CT. In this work, we compared both technologies for imaging of the temporal bone and skull base. A clinical PCCT system and 3 clinical EID CT scanners were used to image the American College of Radiology image quality phantom using a clinical imaging protocol with matched CTDIvol (CT dose index-volume) of 25 mGy. Images were used to characterize the image quality of each system across a series of high-resolution reconstruction options. Noise was calculated from the noise power spectrum, whereas resolution was quantified with a bone insert by calculating a task transfer function. Images of an anthropomorphic skull phantom and 2 patient cases were examined for visualization of small anatomical structures. Across measured conditions, PCCT had a comparable or smaller average noise magnitude (120 Hounsfield units [HU]) to the EID systems (144-326 HU). Photon-counting CT also had comparable resolution (task transfer function f(25): 1.60 mm(-1)) to the EID systems (1.34-1.77 mm(-1)). Imaging results supported quantitative findings as PCCT more clearly showed the 12-lp/cm bars from the fourth section of the American College of Radiology phantom and better represented the vestibular aqueduct and oval and round windows when compared with the EID scanners. A clinical PCCT system was able to image the temporal bone and skull base with improved spatial resolution and lower noise than clinical EID CT systems at matched dose.
引用
收藏
页码:613 / 620
页数:8
相关论文
共 50 条
  • [1] Photon-Counting Detector Computed Tomography Versus Energy-Integrating Detector Computed Tomography for Coronary Artery Calcium Quantitation
    McCollough, Cynthia H.
    Winfree, Tim N.
    Melka, Elnata F.
    Rajendran, Kishore
    Carter, Rickey E.
    Leng, Shuai
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2024, 48 (02) : 212 - 216
  • [2] Photon-counting computed tomography versus energy-integrating computed tomography for detection of small liver lesions: comparison using a virtual framework imaging
    Felice, Nicholas
    Wildman-Tobriner, Benjamin
    Segars, William Paul
    Bashir, Mustafa R.
    Marin, Daniele
    Samei, Ehsan
    Abadi, Ehsan
    JOURNAL OF MEDICAL IMAGING, 2024, 11 (05)
  • [3] Photon-Counting Computed Tomography Versus Energy-Integrating Dual-Energy Computed Tomography: Virtual Noncontrast Image Quality Comparison
    Dane, Bari
    Ruff, Andrew
    O'Donnell, Thomas
    El-Ali, Alexander
    Ginocchio, Luke
    Prabhu, Vinay
    Megibow, Alec
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2024, 48 (02) : 251 - 256
  • [4] High-Pitch Photon-Counting Detector Computed Tomography Angiography of the Aorta Intraindividual Comparison to Energy-Integrating Detector Computed Tomography at Equal Radiation Dose
    Euler, Andre
    Higashigaito, Kai
    Mergen, Victor
    Sartoretti, Thomas
    Zanini, Bettina
    Schmidt, Bernhard
    Flohr, Thomas G.
    Ulzheimer, Stefan
    Eberhard, Matthias
    Alkadhi, Hatem
    INVESTIGATIVE RADIOLOGY, 2022, 57 (02) : 115 - 121
  • [5] Photon-counting detector computed tomography in cardiac imaging
    Sharma, Simran P.
    Lemmens, Marie-Julie D. K.
    Smulders, Martijn W.
    Budde, Ricardo P. J.
    Hirsch, Alexander
    Mihl, Casper
    NETHERLANDS HEART JOURNAL, 2024, 32 (11) : 405 - 416
  • [6] Photon-counting computed tomography of coronary and peripheral artery stents: a phantom study
    Thomas Stein
    Jana Taron
    Niklas Verloh
    Michael Doppler
    Alexander Rau
    Muhammad Taha Hagar
    Sebastian Faby
    Dimos Baltas
    Dirk Westermann
    Isabelle Ayx
    Stefan O. Schönberg
    Konstantin Nikolaou
    Christopher L. Schlett
    Fabian Bamberg
    Jakob Weiss
    Scientific Reports, 13
  • [7] Photon-counting computed tomography of coronary and peripheral artery stents: a phantom study
    Stein, Thomas
    Taron, Jana
    Verloh, Niklas
    Doppler, Michael
    Rau, Alexander
    Hagar, Muhammad Taha
    Faby, Sebastian
    Baltas, Dimos
    Westermann, Dirk
    Ayx, Isabelle
    Schoenberg, Stefan O.
    Nikolaou, Konstantin
    Schlett, Christopher L.
    Bamberg, Fabian
    Weiss, Jakob
    SCIENTIFIC REPORTS, 2023, 13 (01)
  • [8] High-Resolution Chest Computed Tomography Imaging of the Lungs Impact of 1024 Matrix Reconstruction and Photon-Counting Detector Computed Tomography
    Bartlett, David J.
    Koo, Chi Wan
    Bartholmai, Brian J.
    Rajendran, Kishore
    Weaver, Jayse M.
    Halaweish, Ahmed E.
    Leng, Shuai
    McCollough, Cynthia H.
    Fletcher, Joel G.
    INVESTIGATIVE RADIOLOGY, 2019, 54 (03) : 129 - 137
  • [9] Reduced Intravenous Contrast Dose Portal Venous Phase Photon-Counting Computed Tomography Compared With Conventional Energy-Integrating Detector Portal Venous Phase Computed Tomography
    Dane, Bari
    Mabud, Tarub
    Melamud, Kira
    Ginocchio, Luke
    Smereka, Paul
    Okyere, Mabel
    O'Donnell, Thomas
    Megibow, Alec
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2024, 48 (05) : 675 - 682
  • [10] Photon-Counting Computed Tomography for Microstructural Imaging of Bone and Joints
    Quintiens, Jilmen
    van Lenthe, G. Harry
    CURRENT OSTEOPOROSIS REPORTS, 2024, 22 (04) : 387 - 395