A proof of concept for reliability aware analysis of junctionless negative capacitance FinFET-based hydrogen sensor

被引:3
|
作者
Gandhi, Navneet [1 ]
Jaisawal, Rajeewa Kumar [1 ]
Rathore, Sunil [1 ]
Kondekar, P. N. [1 ]
Bagga, Navjeet [2 ]
机构
[1] PDPM Indian Inst Informat Technol Design & Mfg, Dept Elect & Commun Engn, Jabalpur 482005, India
[2] Indian Inst Technol Bhubaneswar, Sch Elect Sci, Bhubaneswar, India
关键词
junctionless FinFET; negative capacitance; hydrogen gas sensor; work function variability; random dopant fluctuation; reliability analysis; GATE; SENSITIVITY;
D O I
10.1088/1361-665X/ad2028
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
This work demonstrates the reliability-aware analysis of the Junctionless negative capacitance (NC) FinFET employed as a hydrogen (H2) gas sensor. Gate stacking of the ferroelectric (FE) layer induces internal voltage amplification owing to the NC property, thus, improving the sensitivity of the baseline junctionless FinFET. A well-calibrated TCAD model is used to investigate the sensing characteristics of the proposed FinFET-based H2 sensor by employing the palladium (Pd) metallic gate as a sensing element. The mechanism involves the transduction of H2 gas molecules over the metal gate; due to the diffusion process, some atomic hydrogen diffuses into the metal. The H2 gas absorption at the metal surface causes a dipole layer formation at the gate and oxide interface, which changes the metal gate work function. As a result, this change in the work function can be used as a sensing parameter of the proposed gas sensor. Further, the threshold voltage and other electrical characteristics, such as output conductance, transconductance, and drain current are examined for sensitivity analysis for both NC and without NC JL FinFET at different pressure ranges, keeping the temperature constant (i.e. 300 K). The device variation, i.e. Fin thickness, Fin height, doping and thickness of HfO2 ferroelectric layer, etc, on sensor sensitivity has been evaluated through extensive simulation. This paper also presents a detailed investigation of the sensor's reliability in terms of work function variation, random dopant fluctuation, trap charges, and device aging, i.e. end of a lifetime. At last, the acquired results are compared with earlier reported data, which justifies the profound significance of the proposed junctionless negative capacitance FinFET-based H2 gas sensor.
引用
收藏
页数:11
相关论文
共 26 条
  • [21] Charge-Plasma-Based Negative Capacitance Ring-FET: Design, Investigation and Reliability Analysis
    Ashok Kumar Gupta
    Ashish Raman
    Naveen Kumar
    Journal of Electronic Materials, 2020, 49 : 4852 - 4863
  • [22] Interface traps in the sub-3 nm technology node: A comprehensive analysis and benchmarking of negative capacitance FinFET and nanosheet FETs - A reliability perspective from device to circuit level
    Valasa, Sresta
    Kotha, Venkata Ramakrishna
    Vadthiya, Narendar
    MICROELECTRONICS RELIABILITY, 2024, 160
  • [23] Sensor-based gait analysis using mobile phones is useful for the assessment of fatigue in patients with multiple sclerosis - a proof of concept study
    Schoenherr, C.
    Strauss, S.
    Ziegler, J.
    Zentek, T.
    Rashid, A.
    Tallner, A.
    Grothe, M.
    MULTIPLE SCLEROSIS JOURNAL, 2022, 28 (3_SUPPL) : 710 - 711
  • [24] Gold nanoparticles based sensor for in vitro analysis of drug-drug interactions using imipramine and isoniazid drugs: A proof of concept approach
    Shaikh, Tayyaba
    Pandey, Ashish
    Sirajuddin
    Talpur, Farah N.
    Kaushik, Aman
    Niazi, Javed H.
    SENSORS AND ACTUATORS B-CHEMICAL, 2017, 252 : 1055 - 1062
  • [25] Post-exercise Response of Arterial Parameters for Arterial Health Assessment Using a Microfluidic Tactile Sensor and Vibration-Model-Based Analysis: A Proof-of-Concept Study
    Zhili Hao
    Dan Wang
    Leryn Reynolds
    Cardiovascular Engineering and Technology, 2020, 11 : 295 - 307
  • [26] Post-exercise Response of Arterial Parameters for Arterial Health Assessment Using a Microfluidic Tactile Sensor and Vibration-Model-Based Analysis: A Proof-of-Concept Study
    Hao, Zhili
    Wang, Dan
    Reynolds, Leryn
    CARDIOVASCULAR ENGINEERING AND TECHNOLOGY, 2020, 11 (03) : 295 - 307