Investigation on pitting corrosion mechanism of the Fe-based amorphous alloy coating by three-dimensional X-ray imaging at micro-scale

被引:2
|
作者
Wang, Mengru [1 ]
Zhong, Yan [2 ]
Liang, Dandan [3 ]
Liu, Tao [4 ]
Wei, Xianshun [1 ]
Zhang, Yongming [1 ]
Chen, Bo [1 ]
机构
[1] Tongji Univ, Sch Mat Sci & Engn, Key Lab Adv Civil Engn Mat, Minist Educ, Shanghai 201804, Peoples R China
[2] Shanghai Highway Investment Construct & Dev Co Ltd, Shanghai 200336, Peoples R China
[3] Superhard Coating & Equipment Shanghai Inst Tech, Shanghai Engn Res Ctr Phys Vapor Deposit PVD, Shanghai, Peoples R China
[4] Tongji Univ, Coll Civil Engn, Shanghai 200092, Peoples R China
基金
中国国家自然科学基金;
关键词
Fe-based amorphous alloy coating; (Fe-based AAC); Corrosion behavior; X-ray micro-computed tomography; (X-ray micro-CT); Three-dimensional analysis; Pitting corrosion; BULK METALLIC-GLASS; LOCALIZED CORROSION; STAINLESS-STEEL; RESISTANCE; BEHAVIOR; MICROTOMOGRAPHY; INITIATION; ROUGHNESS; KINETICS; GROWTH;
D O I
10.1016/j.jmrt.2023.09.026
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Few work have been performed regarding the quantitative characterization of threedimensional (3D) pitting corrosion process directly, although the corrosion behaviors and the passivation film stability of metals in various solutions have been studied heavily. The reported work quantitatively characterized the 3D pitting corrosion of the Fe-based amorphous alloy coating (Fe-based AAC) via X-ray micro-computed tomography (X-ray micro-CT) and further elucidated the mechanism of its pitting corrosion. Moreover, the microstructure and electrochemical performance of the Fe-based AAC have also been explored. The results showed that the targeted thermal sprayed Fe43Cr20Mo10W4C15B6Y2 coating was prone to be corroded with the increase of the hydrogen ion concentration, i.e. higher hydrogen ion concentration leads to poorer corrosion performance of the Fe-based AAC. The X-ray micro-CT results revealed that the pits in the Fe-based AAC initially nucleated below the pitting potential, and they also generated in the over-passivation stage. Furthermore, it was found that the corrosive medium does not penetrate into the coating/substrate interface, and the deduced corrosion mechanism from the findings was also discussed.(c) 2023 The Author(s). Published by Elsevier B.V. This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/).
引用
收藏
页码:6405 / 6418
页数:14
相关论文
共 50 条
  • [31] Three-dimensional reconstruction of maize roots and quantitative analysis of metaxylem vessels based on X-ray micro-computed tomography
    Pan, Xiaodi
    Ma, Liming
    Zhang, Ying
    Wang, Jinglu
    Du, Jianjun
    Guo, Xinyu
    CANADIAN JOURNAL OF PLANT SCIENCE, 2018, 98 (02) : 457 - 466
  • [32] Particle Coagulation in Molten Metal Based on Three-Dimensional Analysis of Cluster by X-Ray Micro-Computer Tomography (CT)
    Li, Tao
    Shimasaki, Shin-ichi
    Taniguchi, Shoji
    Uesugi, Kentaro
    Narita, Shunsuke
    ISIJ INTERNATIONAL, 2013, 53 (11) : 1958 - 1967
  • [33] Particle Coagulation in Molten Metal Based on Three-Dimensional Analysis of Cluster by X-Ray Micro-Computer Tomography (CT)
    Li, Tao
    Shimaski, Shin-ichi
    Taniguchi, Shoji
    Uesugi, Kentaro
    Narita, Shunsuke
    TETSU TO HAGANE-JOURNAL OF THE IRON AND STEEL INSTITUTE OF JAPAN, 2015, 101 (02): : 158 - 167
  • [34] Three-dimensional X-ray micro-tomography based microstructure and mechanical performance of hybrid laser welded AA7020
    Hu Y.
    Wu S.
    Zhang S.
    Jiao H.
    Fu Y.
    Zhongguo Jiguang/Chinese Journal of Lasers, 2016, 43 (01):
  • [35] X-Ray Micro-CT and Digital-Volume Correlation Based Three-Dimensional Measurements of Deformation and Strain in Operational Electronics
    Lall, Pradeep
    Wei, Junchao
    2015 IEEE 65TH ELECTRONIC COMPONENTS AND TECHNOLOGY CONFERENCE (ECTC), 2015, : 406 - 416
  • [36] 2D X-ray diffraction method for evaluating the local crystallization of Fe-based amorphous alloy ribbon induced by ultrashort pulsed laser local heating
    Kuji, Chieko
    Mizutani, Masayoshi
    Kuriyagawa, Tsunemoto
    Soyama, Hitoshi
    MATERIALS TODAY COMMUNICATIONS, 2023, 37
  • [37] Three-dimensional imaging of whole mouse models: comparing nondestructive X-ray phase-contrast micro-CT with cryotome-based planar epi-illumination imaging
    Tapfer, A.
    Bech, M.
    Zanette, I.
    Symvoulidis, P.
    Stangl, S.
    Multhoff, G.
    Molls, M.
    Ntziachristos, V.
    Pfeiffer, F.
    JOURNAL OF MICROSCOPY, 2014, 253 (01) : 24 - 30
  • [38] Fracture evolution mechanism of hollow sandstone under conventional triaxial compression by X-ray micro-CT observations and three-dimensional numerical simulations
    Yang, Sheng-Qi
    Yang, Zhen
    Jing, Hong-Wen
    Xu, Tao
    INTERNATIONAL JOURNAL OF SOLIDS AND STRUCTURES, 2020, 190 : 156 - 180
  • [39] Noninvasive Three-Dimensional In Situ and In Vivo Characterization of Bioprinted Hydrogel Scaffolds Using the X-ray Propagation-Based Imaging Technique
    Ning, Liqun
    Zhu, Ning
    Smith, An
    Rajaram, Ajay
    Hou, Huishu
    Srinivasan, Subashree
    Mohabatpour, Fatemeh
    He, Lihong
    Mclnnes, Adam
    Serpooshan, Vahid
    Papagerakis, Petros
    Chen, Xiongbiao
    ACS APPLIED MATERIALS & INTERFACES, 2021, 13 (22) : 25611 - 25623
  • [40] A statistical, task-based evaluation method for three-dimensional x-ray breast imaging systems using variable-background phantoms
    Park, Subok
    Jennings, Robert
    Liu, Haimo
    Badano, Aldo
    Myers, Kyle
    MEDICAL PHYSICS, 2010, 37 (12) : 6253 - 6270