Micro-CT Marginal and Internal Fit Evaluation of CAD/CAM High-Performance Polymer Onlay Restorations

被引:3
|
作者
Toma, Flavia Roxana [1 ]
Moleriu, Lavinia Cristina [2 ]
Porojan, Liliana [1 ]
机构
[1] Victor Babes Univ Med & Pharm Timisoara, Fac Dent Med, Ctr Adv Technol Dent Prosthodont, Dept Dent Prostheses Technol Dent Technol, Eftimie Murgu Sq 2, Timisoara 300041, Romania
[2] Victor Babe? Univ Med & Pharm Timisoara, Dept Funct Sci, Eftimie Murgu Sq 2, Timisoara 300041, Romania
关键词
PAEK; CAD/CAM; marginal and internal fitness; onlay; micro-CT evaluation; LOAD-BEARING CAPACITY; FIXED DENTAL PROSTHESES; FATIGUE RESISTANCE; COMPOSITE RESIN; ADAPTATION; CROWNS; TECHNOLOGY; ACCURACY; STRENGTH; FRACTURE;
D O I
10.3390/polym15071715
中图分类号
O63 [高分子化学(高聚物)];
学科分类号
070305 ; 080501 ; 081704 ;
摘要
(1) Background: The use of high-performance polymers for fixed restorations requires additional studies regarding their adaptability and processing with CAD/CAM technology. This in vitro study aims to assess the marginal and internal fit of PEEK and PEKK materials using microcomputed tomography. (2) Methods: Twenty-four (n = 8) MOD onlays made of PEKK (Pekkton ivory), unmodified PEEK (Juvora medical), and modified PEEK (BioHPP) were investigated. A typodont mandibular left first molar was scanned to achieve 24 resin, 3D printed abutment teeth. The onlays were fabricated with a five-axis milling machine, and after cementation of the specimens, the marginal (MG) and internal gaps (IG) were evaluated at twelve points in the mesio-distal section and thirteen points in the bucco-lingual section using microcomputed tomography. For statistical data analysis, Wilcoxon signed-rank/paired Student t-Test, Mann-Whitney/unpaired Student t-Test, and one-way ANOVA test were applied. (3) Results: Significant differences (p < 0.05; a = 0.05) were reported between the MG and IG for each material for all three polymers and also among two materials in terms of the MG and IG (except Juvora-BioHPP). The highest IG values were recorded in angular areas (axio-gingival line angle) in the mesio-distal section for all the polymers. (4) Conclusions: For all the materials, MG < IG. The type of polymer influenced the adaptability; the lowest marginal and internal gap mean values were recorded for BioHPP. The analyzed polymer used for onlays are clinically acceptable in terms of adaptability.
引用
收藏
页数:13
相关论文
共 49 条
  • [1] Marginal and internal fit of CAD-CAM inlay/onlay restorations: A systematic review of in vitro studies
    Goujat, Alexis
    Abouelleil, Hazem
    Colon, Pierre
    Jeannin, Christophe
    Pradelle, Nelly
    Seux, Dominique
    Grosgogeat, Brigitte
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2019, 121 (04): : 590 - +
  • [2] Evaluation of marginal and internal fit of lithium disilicate CAD-CAM crowns with different finish lines by using a micro-CT technique
    Rizonaki, Maria
    Jacquet, Wolfgang
    Bottenberg, Peter
    Depla, Lennert
    Boone, Matthieu
    De Coster, Peter J.
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2022, 127 (06): : 890 - 898
  • [3] Micro-CT Analysis of Y-TZP Copings Made by Different CAD/CAM Systems: Marginal and Internal Fit
    Saab, Rafaella Caramori
    da Cunha, Leonardo Fernandes
    Gonzaga, Carla Castiglia
    Mushashe, Amanda Mahammad
    Correr, Gisele Maria
    [J]. INTERNATIONAL JOURNAL OF DENTISTRY, 2018, 2018
  • [4] Effect of Chairside CAD/CAM Restoration Type on Marginal Fit Accuracy: A Comparison of Crown, Inlay and Onlay Restorations
    Merrill, Tyson C.
    Mackey, Thomas
    Luc, Raymond
    Lung, Dominique
    Naseem, Aneela
    Abduo, Jaafar
    [J]. EUROPEAN JOURNAL OF PROSTHODONTICS AND RESTORATIVE DENTISTRY, 2021, 29 (02): : 119 - 127
  • [5] Micro-CT evaluation of fit of CAD/CAM occlusal veneers with Er:YAG laser treatment on dentin
    Li, Qiushi
    Qu, Zhou
    Si, Xi
    Li, Meihua
    [J]. ADVANCED LASER TECHNOLOGY AND APPLICATIONS, 2018, 10844
  • [6] Marginal Fit Evaluation of CAD/CAM All Ceramic Crowns Obtained by Two Digital Workflows: An In Vitro Study Using Micro-CT Technology
    Duqum, Ibrahim Salim
    Brenes, Christian
    Mendonca, Gustavo
    Prado Naves Carneiro, Thiago Almedia
    Cooper, Lyndon F.
    [J]. JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2019, 28 (09): : 1037 - 1043
  • [7] Evaluation of Marginal and Internal Fit of CAD/CAM Endocrowns with Different Cavity Tapers
    Hajimahmoodi, Mohammedreza
    Raseipour, Sasan
    Mroue, Mohammad
    Ghodsi, Safoura
    [J]. INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2023, 36 (02) : 189 - 193
  • [8] Micro-CT Evaluation of Ceramic Inlays: Comparison of the Marginal and Internal Fit of Five and Three Axis CAM Systems wits a Heat Press Technique
    Alajaji, Norah K.
    Bardwell, David
    Finkelman, Matthew
    Ali, Ala
    [J]. JOURNAL OF ESTHETIC AND RESTORATIVE DENTISTRY, 2017, 29 (01) : 49 - 58
  • [9] Effect of different preparation finishing procedures on the marginal and internal fit of CAD-CAM-produced restorations: A microcomputed tomography evaluation
    Tamam, Evsen
    Gungor, Merve Bankoglu
    Nemli, Secil Karakoca
    Ocak, Mert
    Bilecenog, Burak
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2023, 130 (04): : 605 - 610
  • [10] Micro-CT analysis of marginal and internal fit of milled and pressed polyetheretherketone single crowns
    Attia, Mazen A.
    Blunt, Liam
    Bills, Paul
    Tawfik, Ahmed
    Radawn, Mohamed
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2023, 129 (06): : 906e1 - 906e10