Design, optimization, and analysis of a human-machine compatibility upper extremity exoskeleton rehabilitation robot

被引:3
|
作者
Ning, Yuansheng [1 ,2 ]
Wang, Hongbo [1 ,2 ,3 ,4 ]
Tian, Junjie [1 ,2 ]
Zhu, Pan [1 ,2 ]
Yang, Congliang [1 ,2 ]
Niu, Jianye [1 ,2 ]
机构
[1] Yanshan Univ, Parallel Robot & Mechatron Syst Lab Hebei Prov, 438 Hebei St, Qinhuangdao 066004, Peoples R China
[2] Yanshan Univ, Key Lab Adv Forging & Stamping Technol & Sci, Minist Educ, Qinhuangdao, Peoples R China
[3] Fudan Univ, Acad Engn & Technol, Shanghai, Peoples R China
[4] Shanghai Clin Res Ctr Aging & Med, Shanghai, Peoples R China
基金
中国国家自然科学基金;
关键词
Upper extremity rehabilitation exoskeleton robot; mechanism optimization; movement space; human-machine compatibility; ANATOMY; ARMIN;
D O I
10.1177/09544062221139988
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
For rehabilitation therapy robots, the movement range, and comfort of rehabilitation are crucial to the patient's training and recovery and are also key factors in the design and performance evaluation of rehabilitation robots. In this paper, a highly harmonized upper extremity rehabilitation robot was proposed based on the human-machine coupling system model. Meanwhile, the shoulder joint structure of the rehabilitation robot was optimized to study the workspace range of this robot, the workspace of the upper extremity rehabilitation robot was fitted based on kinematic equations and the workspace volume size for different shoulder joint angles was analyzed. Finally, the upper extremity exoskeleton rehabilitation robot prototype was used to conduct the movement range tracking experiment and human-machine compatibility experiment in healthy volunteers to verify the rehabilitation training range and movement comfort of the rehabilitation robot. The experimental results show that when the optimized upper extremity exoskeleton rehabilitation robot was used to move in the coronal plane and sagittal plane of the human body, the overlaps of the movement range of the upper extremity wrist point W and the movement range of the healthy person was 97.23% and 97.66%, respectively, while the human-machine interaction force generated during the movement was mainly concentrated in the range of 0-10 kPa, which belongs to the low-pressure range of human-machine interaction. Therefore, this upper extremity rehabilitation robot can increase the movement range of patients' upper extremities and improve the comfort of rehabilitation training.
引用
收藏
页码:2802 / 2814
页数:13
相关论文
共 50 条
  • [1] Exoskeleton Design and Human-Machine Compatibility Analysis for Shoulder Rehabilitation Based on Synergy Characteristic
    Shen, Huimin
    Ge, Ruikang
    Ge, Di
    Li, Bingchu
    Gan, Yi
    Qin, Longhui
    Yang, Geng
    Jixie Gongcheng Xuebao/Journal of Mechanical Engineering, 2022, 58 (19): : 34 - 44
  • [2] Improvement of human-machine compatibility of upper-limb rehabilitation exoskeleton using passive joints
    Zhang, Leiyu
    Li, Jianfeng
    Su, Peng
    Song, Yanming
    Dong, Mingjie
    Cao, Qiang
    ROBOTICS AND AUTONOMOUS SYSTEMS, 2019, 112 : 22 - 31
  • [3] An Analysis of Human-Machine Interaction to a Lower Extremity Exoskeleton
    Zheng, Xiaojuan
    Xiao, Lan
    Qiu, Jing
    Hou, Lei
    Cheng, Hong
    Chang, Youjun
    MAN-MACHINE-ENVIRONMENT SYSTEM ENGINEERING, 2018, 456 : 535 - 542
  • [4] Mechanical Design and Human-Machine Coupling Dynamic Analysis of a Lower Extremity Exoskeleton
    Li, Bo
    Yuan, Bo
    Chen, Jun
    Zuo, Yonggang
    Yang, Yifu
    INTELLIGENT ROBOTICS AND APPLICATIONS, ICIRA 2017, PT I, 2017, 10462 : 593 - 604
  • [5] An eight-degree-of-freedom upper extremity exoskeleton rehabilitation robot: design, optimization, and validation
    Yuansheng Ning
    Hongbo Wang
    Junjie Tian
    Hao Yan
    Yu Tian
    Congliang Yang
    Jian Wei
    Jianye Niu
    Journal of Mechanical Science and Technology, 2022, 36 : 5721 - 5733
  • [6] An eight-degree-of-freedom upper extremity exoskeleton rehabilitation robot: design, optimization, and validation
    Ning, Yuansheng
    Wang, Hongbo
    Tian, Junjie
    Yan, Hao
    Tian, Yu
    Yang, Congliang
    Wei, Jian
    Niu, Jianye
    JOURNAL OF MECHANICAL SCIENCE AND TECHNOLOGY, 2022, 36 (11) : 5721 - 5733
  • [7] Design and human-machine compatibility analysis of Co-Exos II for upper-limb rehabilitation
    Zhang, Leiyu
    Li, Jianfeng
    Ji, Shuting
    Su, Peng
    Tao, Chunjing
    Ji, Run
    ASSEMBLY AUTOMATION, 2019, 39 (04) : 715 - 726
  • [8] Design and Optimization of Human-Machine Interaction Wearable Device for Lower Limb Rehabilitation Exoskeleton
    Zhang, Yueyang
    Wang, Jianhua
    Chen, Weihai
    Zhang, Jianbin
    Chen, Zuobing
    PROCEEDINGS OF THE 2021 IEEE 16TH CONFERENCE ON INDUSTRIAL ELECTRONICS AND APPLICATIONS (ICIEA 2021), 2021, : 2101 - 2106
  • [9] Hand Exoskeleton Design and Human-Machine Interaction Strategies for Rehabilitation
    Xia, Kang
    Chen, Xianglei
    Chang, Xuedong
    Liu, Chongshuai
    Guo, Liwei
    Xu, Xiaobin
    Lv, Fangrui
    Wang, Yimin
    Sun, Han
    Zhou, Jianfang
    BIOENGINEERING-BASEL, 2022, 9 (11):
  • [10] Design and Verification of a Human-machine Fusion Hand Exoskeleton Robot
    Yu, Jinxu
    Yan, Jianhua
    Wang, Xiaoran
    Zhang, Lijie
    Xie, Ping
    Li, Yongquan
    Jixie Gongcheng Xuebao/Journal of Mechanical Engineering, 2024, 60 (17): : 102 - 110