Impact of Phantom Size on Low-Energy Virtual Monoenergetic Images of Three Dual-Energy CT Platforms

被引:5
|
作者
Greffier, Joel [1 ]
Van Ngoc Ty, Claire [2 ]
Fitton, Isabelle [2 ]
Frandon, Julien [1 ]
Beregi, Jean-Paul [1 ]
Dabli, Djamel [1 ]
机构
[1] Montpellier Univ, Nimes Univ Hosp, Dept Med Imaging, IMAGINE UR UM 103, F-30029 Nimes, France
[2] Univ Paris, Hop Europeen Georges Pompidou, AP HP, Dept Radiol, F-75015 Paris, France
关键词
dual-energy; multidetector computed tomography; task-based image quality assessment; split-filter; RECONSTRUCTION;
D O I
10.3390/diagnostics13193039
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The purpose of this study was to compare the quality of low-energy virtual monoenergetic images (VMIs) obtained with three Dual-Energy CT (DECT) platforms according to the phantom diameter. Three sections of the Mercury Phantom 4.0 were scanned on two generations of split-filter CTs (SFCT-1st and SFCT-2nd) and on one Dual-source CT (DSCT). The noise power spectrum (NPS), task-based transfer function (TTF), and detectability index (d') were assessed on VMIs from 40 to 70 keV. The highest noise magnitude values were found with SFCT-1st and noise magnitude was higher with DSCT than with SFCT-2nd for 26 cm (10.2% +/- 1.3%) and 31 cm (7.0% +/- 2.5%), and the opposite for 36 cm (-4.2% +/- 2.5%). The highest average NPS spatial frequencies and TTF values at 50% (f50) values were found with DSCT. For all energy levels, the f50 values were higher with SFCT-2nd than SFCT-1st for 26 cm (3.2% +/- 0.4%) and the opposite for 31 cm (-6.9% +/- 0.5%) and 36 cm (-5.6% +/- 0.7%). The lowest d' values were found with SFCT-1st. For all energy levels, the d' values were lower with DSCT than with SFCT-2nd for 26 cm (-6.2% +/- 0.7%), similar for 31 cm (-0.3% +/- 1.9%) and higher for 36 cm (5.4% +/- 2.7%). In conclusion, compared to SFCT-1st, SFCT-2nd exhibited a lower noise magnitude and higher detectability values. Compared with DSCT, SFCT-2nd had a lower noise magnitude and higher detectability for the 26 cm, but the opposite was true for the 36 cm.
引用
收藏
页数:13
相关论文
共 50 条
  • [31] Acute cholecystitis: diagnostic value of dual-energy CT-derived iodine map and low-keV virtual monoenergetic images
    Huda, Fahimul
    LeBedis, Christina A.
    Qureshi, Muhammad M.
    Anderson, Stephan W.
    Gupta, Avneesh
    ABDOMINAL RADIOLOGY, 2021, 46 (11) : 5125 - 5133
  • [32] Acute cholecystitis: diagnostic value of dual-energy CT-derived iodine map and low-keV virtual monoenergetic images
    Fahimul Huda
    Christina A. LeBedis
    Muhammad M. Qureshi
    Stephan W. Anderson
    Avneesh Gupta
    Abdominal Radiology, 2021, 46 : 5125 - 5133
  • [33] Image Quality on Dual-energy CTPA Virtual Monoenergetic Images: Quantitative and Qualitative Assessment
    Dane, Bari
    Patel, Hersh
    O'Donnell, Thomas
    Girvin, Francis
    Brusca-Augello, Geraldine
    Alpert, Jeffrey B.
    Niu, Bowen
    Attia, Mariam
    Babb, James
    Ko, Jane P.
    ACADEMIC RADIOLOGY, 2018, 25 (08) : 1075 - 1086
  • [34] Improved Imaging of intraspinal Lymphomas by means of virtual monoenergetic Reconstructions of Dual-energy CT
    Hokamp, Nils Grosse
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2018, 190 (07): : 638 - +
  • [35] Technical Note: Improved CT number stability across patient size using dual-energy CT virtual monoenergetic imaging
    Michalak, Gregory
    Grimes, Joshua
    Fletcher, Joel
    Halaweish, Ahmed
    Yu, Lifeng
    Leng, Shuai
    McCollough, Cynthia
    MEDICAL PHYSICS, 2016, 43 (01) : 513 - 517
  • [36] Low-KeV Virtual Monoenergetic Dual-Energy CT with Deep Learning Reconstruction for Assessing Hepatocellular Carcinoma
    Ota, Takashi
    Nakamoto, Atsushi
    Onishi, Hiromitsu
    Tsuboyama, Takahiro
    Matsumoto, Shohei
    Fukui, Hideyuki
    Kaketaka, Koki
    Honda, Toru
    Kiso, Kengo
    Tatsumi, Mitsuaki
    Tomiyama, Noriyuki
    JOURNAL OF MEDICAL AND BIOLOGICAL ENGINEERING, 2024, 44 (02) : 293 - 306
  • [37] Pancreatic cancer detection with dual-energy CT: diagnostic performance of 40 keV and 70 keV virtual monoenergetic images
    Yoshifumi Noda
    Tomohiro Ando
    Tetsuro Kaga
    Nao Yamda
    Takuya Seko
    Takuma Ishihara
    Nobuyuki Kawai
    Toshiharu Miyoshi
    Akio Ito
    Takuya Naruse
    Fuminori Hyodo
    Hiroki Kato
    Avinash R. Kambadakone
    Masayuki Matsuo
    La radiologia medica, 2024, 129 : 677 - 686
  • [38] Virtual monoenergetic images from dual-energy CT: systematic assessment of task-based image quality performance
    Cester, Davide
    Eberhard, Matthias
    Alkadhi, Hatem
    Euler, Andre
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2022, 12 (01) : 726 - +
  • [39] Pancreatic cancer detection with dual-energy CT: diagnostic performance of 40 keV and 70 keV virtual monoenergetic images
    Noda, Yoshifumi
    Ando, Tomohiro
    Kaga, Tetsuro
    Yamda, Nao
    Seko, Takuya
    Ishihara, Takuma
    Kawai, Nobuyuki
    Miyoshi, Toshiharu
    Ito, Akio
    Naruse, Takuya
    Hyodo, Fuminori
    Kato, Hiroki
    Kambadakone, Avinash R.
    Matsuo, Masayuki
    RADIOLOGIA MEDICA, 2024, 129 (05): : 677 - 686
  • [40] Dual-energy CT with virtual monoenergetic images and iodine maps improves tumor conspicuity in patients with pancreatic ductal adenocarcinoma
    Liang, Hongwei
    Zhou, Yang
    Zheng, Qiao
    Yan, Gaowu
    Liao, Hongfan
    Du, Silin
    Zhang, Xiaohui
    Lv, Fajin
    Zhang, Zhiwei
    Li, Yong-mei
    INSIGHTS INTO IMAGING, 2022, 13 (01)