Achieving high maturation and cannulation rates of radial-cephalic arteriovenous fistulas with VasQ™ device

被引:2
|
作者
Shahverdyan, Robert [1 ]
Hentschel, Dirk M. [2 ]
机构
[1] Asklepios Clin Barmbek, Vasc Access Ctr, Ruebenkamp 220, D-22307 Hamburg, Germany
[2] Brigham & Womens Hosp, Intervent Nephrol, 75 Francis St, Boston, MA 02115 USA
关键词
VASCULAR ACCESS; HEMODIALYSIS ACCESS; PATENCY; VONAPANITASE; OUTCOMES;
D O I
10.1111/sdi.13065
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Background Hemodialysis is the predominant treatment modality for chronic kidney disease, with arteriovenous fistula (AVF) being considered to be the preferred type of long-term vascular access. Implantation of the external anastomotic VasQ (TM) support device during AVF creation has been suggested to improve the functional outcomes of AVFs. In the current study, we report the clinical outcomes when using the device with radial-cephalic AVF (RCAVF) creation in a large cohort over 3 years. Methods One hundred fifty RCAVFs were created between June 2018 and August 2021 with implantation of VasQ (TM). Time to maturation, cannulation characteristics, and assisted (AP) and secondary patency (SP) rates were analyzed. Results In this predominantly male (68%), median 64 years old cohort, 150 VasQ (TM) devices were implanted. Physiological maturation was achieved in 142/150 (95%) and was unassisted in 133/150 (89%). Of those, 129 matured within 1 month and four additional AVFs within 165 days. Eight AVFs achieved maturation following percutaneous transluminal angioplasty, and one required surgical patch angioplasty. The median time from creation to first successful cannulation in dialysis patients was 41 days. AP at 6, 12, 18, 24, and 30 months was 89%, 81%, 78%, 73%, and 73%, and SP was 94%, 87%, 86%, 84%, and 84%, respectively. Conclusions Consistent use of the VasQ (TM) device in RCAVF creation demonstrates excellent AVF maturation and patency rates with very low frequency of assisted maturation and interventions for maintenance. The VasQ (TM) device appears a suitable aid in increasing the creation of functional RCAVFs.
引用
下载
收藏
页码:147 / 154
页数:8
相关论文
共 46 条
  • [31] Radial artery diameterand and age related functional maturation of the radio-cephalic arteriovenous fistula
    Wan, Zi-ming
    Hu, Bo
    Lai, Qi-quan
    Gao, Xue-jing
    Tu, Bo
    Zhou, Yu
    Zhao, Wen-bo
    BMC NEPHROLOGY, 2020, 21 (01)
  • [32] Radial artery diameterand and age related functional maturation of the radio-cephalic arteriovenous fistula
    Zi-ming Wan
    Bo Hu
    Qi-quan Lai
    Xue-jing Gao
    Bo Tu
    Yu Zhou
    Wen-bo Zhao
    BMC Nephrology, 21
  • [33] HAEMODYNAMIC CARDIAC MODIFICATION OCCURING AFTER HIGH FLOW REDUCTION BY PROXIMAL RADIAL ARTERY LIGATION OF RADIAL-CEPHALIC FISTULA FOR HAEMODIALYSIS
    Scrivano, Jacopo
    Pettorini, Laura
    Rutigliano, Teresa
    Ciavarella, Giuseppino M.
    De Biase, Luciano
    Punzo, Giorgio
    Mene, Paolo
    Pirozzi, Nicola
    NEPHROLOGY DIALYSIS TRANSPLANTATION, 2014, 29 : 250 - 251
  • [34] A MODIFIED NO-TOUCH TECHNIQUE PROMOTES MATURATION OF AUTOGENOUS RADIO CEPHALIC ARTERIOVENOUS FISTULAS: A NEW SURGICAL APPROACH
    Wang, Xiaohe
    Zhang, Yuanyuan
    Liu, Zhen
    Wang, Jiaying
    Hou, Guocun
    NEPHROLOGY, 2021, 26 : 27 - 29
  • [35] Low-Volume Flows After Balloon-Assisted Maturation Correlate With High Maturation Failures of Arteriovenous Fistulas
    Assi, Sami
    Alie-Cusson, Fanny S.
    Dexter, David J.
    Rathore, Animesh
    Panneton, Jean M.
    JOURNAL OF VASCULAR SURGERY, 2019, 69 (06) : E276 - E276
  • [36] Arteriovenous Fistulas for Hemodialysis: Application of High-Frequency US to Assess Vein Wall Morphology for Cannulation Readiness
    Jaberi, Arash
    Muradali, Derek
    Marticorena, Rosa M.
    Dacouris, Niki
    Boutin, Adrien
    Mulligan, Anna M.
    Ballyk, Peter D.
    Prabhudesai, Vikramaditya
    Campbell, Vern M.
    Donnelly, Sandra M.
    RADIOLOGY, 2011, 261 (02) : 616 - 624
  • [37] Patency and functionality of radiocephalic arteriovenous fistulas with an external support device (VasQ™): Real-world single-center experience (vol 91, pg 313, 2020)
    Shahverdyan, R.
    Meyer, T.
    Matoussevitch, V
    JOURNAL OF VASCULAR ACCESS, 2021, 22 (05): : 859 - 860
  • [38] Optimal Cutoff Values for Radial Artery Diameter in Secondary Patency Rates and Risk Factors Affecting of Arteriovenous Fistulas
    Utsunomiya, Hiroki
    Fukuya, Yasuhiko
    Sotozaki, Norikazu
    Koga, Yasushi
    ANNALS OF VASCULAR SURGERY, 2019, 54 : 254 - 260
  • [39] Use of the trispan device to assist coil embolization of high-flow arteriovenous fistulas
    Weill, A
    Roy, D
    Georganos, SA
    Guilbert, F
    Raymond, J
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2002, 23 (07) : 1149 - 1152
  • [40] RHE EFFECT OF ANASTOMOTIC ANGLE ON MATURATION OF AUTOGENOUS ARTERIOVENOUS FISTULA AFTER END-TO-SIDE ANASTOMOSIS OF CEPHALIC VEIN AND RADIAL ARTERY
    Li, Le
    Pai, Ming-Chu Pearl
    He, Haiyan
    Ma, Xuejuan
    Cui, Liwen
    NEPHROLOGY DIALYSIS TRANSPLANTATION, 2023, 38 : I733 - I733