Switching Loss Reduction Method for Instantaneous Reactive Power Compensator in Three-Phase Rectifier System

被引:2
|
作者
Surasak, Nuilers [1 ]
Fujita, Hideaki [1 ]
机构
[1] Tokyo Inst Technol, Dept Elect & Elect Engn, Tokyo 1528552, Japan
关键词
Dead-time compensation; discontinuous pulsewidth modulation; instantaneous reactive power compensator (IRPC); switching loss; three-phase rectifier; zero-voltage switch; PWM RECTIFIER; SPACE-VECTOR; MODULATION; ESSENCE;
D O I
10.1109/JESTPE.2022.3216954
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This article discusses a switching loss reduction method for an instantaneous reactive power compensator (IRPC) of a rectifier system that consists of a three-phase synchronous rectifier and a buck converter. The compensator generates a compensating current to suppress the instantaneous reactive power produced by the rectifier, resulting in a sinusoidal three-phase grid current. Zero-voltage switching (ZVS) and discontinuous pulsewidth modulation are used to reduce the switching power loss caused by the high peak of the compensating current in the compensator. A new dead-time compensation method is developed based on switching current estimation to reduce the harmonic distortion of the grid current. A 4.5-kW experimental setup was used to verify the effectiveness of the proposed methods. These methods are found to improve the grid current with a total harmonic distortion (THD) of around 3%; and a peak efficiency of 99.2%