A Three-Phase Grid-Connected Inverter Equipped With a Shunt Instantaneous Reactive Power Compensator

被引:15
|
作者
Takagi, Kazuto [1 ,2 ]
Fujita, Hideaki [1 ]
机构
[1] Tokyo Inst Technol, Dept Elect & Elect Engn, Tokyo 1528552, Japan
[2] Sanken Elect Co Ltd, Saitama 3501155, Japan
关键词
AC inductor; grid-connected inverter; instantaneous reactive power; photovoltaic (PV) inverter; switching loss;
D O I
10.1109/TIA.2019.2910487
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
This paper introduces a three-phase grid-connected inverter for commercial-scale photovoltaic systems. The circuit topology combines an ac-inductor-less active bridge with a parallel-connected pulsewidth modulation inverter acting as an instantaneous reactive power compensator. The active bridge, called a 120 degrees conduction inverter, operates at a switching frequency equal to the grid frequency and outputs a 120 degrees rectangular current, while the compensator eliminates the harmonic currents included in the rectangular current. The main advantage of this strategy is the reduction in size of the required ac inductor by a factor of 4, as well as the reduction of power losses in the switching devices. The theoretical analysis clearly shows that the compensator can synthesize a sinusoidal output current by controlling only instantaneous reactive power, thus eliminating the need for electrolytic capacitors. A 5-kW experimental setup validates the operating principle and the control method of the proposed inverter and exhibits an inverter efficiency as high as 99.2% with Si superjunction MOSFETs.
引用
收藏
页码:3955 / 3966
页数:12
相关论文
共 50 条
  • [1] A Three-Phase Grid-Connected Inverter Equipped With a Shunt Instantaneous Reactive Power Compensator
    Takagi, Kazuto
    Fujita, Hideaki
    [J]. 2017 IEEE ENERGY CONVERSION CONGRESS AND EXPOSITION (ECCE), 2017, : 589 - 596
  • [2] A three-phase grid-connected inverter equipped with a shunt instantaneous reactive power compensator
    Takagi, Kazuto
    Fujita, Hideaki
    [J]. IEEJ Transactions on Industry Applications, 2018, 138 (06) : 530 - 537
  • [3] Reactive Power Control in Three-Phase Grid-Connected Current Source Boost Inverter
    Saghaleini, Mahdi
    Mirafzal, Behrooz
    [J]. 2012 TWENTY-SEVENTH ANNUAL IEEE APPLIED POWER ELECTRONICS CONFERENCE AND EXPOSITION (APEC), 2012, : 904 - 910
  • [4] A ZVS Grid-Connected Three-Phase Inverter
    Li, Rui
    Ma, Zhiyuan
    Xu, Dehong
    [J]. IEEE TRANSACTIONS ON POWER ELECTRONICS, 2012, 27 (08) : 3595 - 3604
  • [5] Research on MRSMC for Three-phase Grid-Connected Inverter
    Hu, Qinjun
    Zhang, Zhilin
    Liu, Hua
    Zhang, Liang
    [J]. 2019 IEEE INTERNATIONAL SYMPOSIUM ON PREDICTIVE CONTROL OF ELECTRICAL DRIVES AND POWER ELECTRONICS (PRECEDE 2019), 2019, : 304 - 307
  • [6] Power Controller Effects for Mitigating Harmonics in a Three-Phase Grid-Connected Inverter
    Ismail, F.
    Jamaludin, J.
    Rahim, N. A.
    [J]. IEACON 2021: 2021 IEEE INDUSTRIAL ELECTRONICS AND APPLICATIONS CONFERENCE (IEACON), 2021, : 151 - 156
  • [7] Control for Grid-Connected and Stand-Alone Operations of Three-Phase Grid-Connected Inverter
    Thanh-Vu Tran
    Chun, Tae-Won
    Lee, Hong-Hee
    Kim, Heung-Geun
    Nho, Eui-Cheol
    [J]. INTERNATIONAL CONFERENCE ON RENEWABLE ENERGY RESEARCH AND APPLICATIONS (ICRERA), 2012,
  • [8] Three-Phase Boost-Type Grid-Connected Inverter
    Chen, Yang
    Smedley, Keyue
    [J]. IEEE TRANSACTIONS ON POWER ELECTRONICS, 2008, 23 (05) : 2301 - 2309
  • [9] Improved control strategy for the three-phase grid-connected inverter
    Yao, Zhilei
    Xiao, Lan
    Guerrero, Josep M.
    [J]. IET RENEWABLE POWER GENERATION, 2015, 9 (06) : 587 - 592
  • [10] Adaptive Fuzzy Control of Three-Phase Grid-Connected Inverter
    Shadoul, Myada
    Yousef, Hassan
    Al Abri, Rashid
    Al Hinai, Amer
    [J]. 2021 12TH INTERNATIONAL RENEWABLE ENGINEERING CONFERENCE (IREC 2021), 2021, : 94 - 99