Safety and efficacy of cerebral embolic protection devices for patients undergoing transcatheter aortic valve replacement: An updated meta-analysis

被引:4
|
作者
Shrestha, Dhan Bahadur [1 ]
Shtembari, Jurgen [1 ]
Lamichhane, Sandesh [2 ]
Baniya, Abinash [2 ]
Shahi, Manoj [2 ]
Dhungel, Swati [3 ]
Pant, Kailash [4 ]
Sutton, Nadia R. [5 ,6 ]
Villablanca, Pedro [7 ]
Mungee, Sudhir [4 ]
机构
[1] Mt Sinai Hosp, Dept Internal Med, Chicago, IL USA
[2] Chitwan Med Coll Teaching Hosp, Dept Internal Med, Bharatpur, Nepal
[3] John H Stroger Jr Hosp Cook Cty, Dept Internal Med, Div Cardiovasc Med, Chicago, IL USA
[4] Univ Illinois, Dept Internal Med, Div Cardiovasc Med, Coll Med,OSF Healthcare, Peoria, IL USA
[5] Vanderbilt Univ, Med Ctr, Dept Internal Med, Div Cardiovasc Med, Nashville, TN USA
[6] Vanderbilt Univ, Dept Biomed Engn, Nashville, TN USA
[7] Henry Ford Hosp, Ctr Struct Heart Dis, Dept Internal Med, Div Intervent Cardiol & Struct Heart Dis, Detroit, MI USA
关键词
cerebral embolic protection devices; stroke; transcatheter aortic valve replacement; RANDOMIZED EVALUATION; RISK-FACTORS; CEREBROVASCULAR EVENTS; DEFLECTION DEVICE; IMPLANTATION; STENOSIS; STROKE; IMPROVEMENT; OUTCOMES; LESIONS;
D O I
10.1002/hsr2.1391
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
Background and AimsCerebral embolic protection (CEP) devices are employed to capture embolic debris and reduce the risk of stroke during transcatheter aortic valve replacement (TAVR). Evidence is mixed regarding the safety and efficacy of CEP. We aimed to summarize the safety and effectiveness of CEP use during TAVR. MethodsElectronic databases, including PubMed, PubMed Central, Scopus, Cochrane Library, and Embase, were searched using relevant search terms for articles relating to CEP. All relevant data from 20 studies were extracted into a standardized form. Statistical analyses were performed using Revman 5.4. Odds ratio (OR) or mean differences (MDs) were used to estimate the desired outcome with a 95% confidence interval (CI). ResultsTwenty studies (eight randomized controlled trials [RCTs]) involving 210,871 patients (19,261 in the CEP group and 191,610 in TAVR without the CEP group) were included. The use of CEP was associated with a lower odds of 30-day mortality by 39% (OR: 0.61, 95% CI: 0.53-0.70) and stroke by 31% (OR: 0.69, 95% CI: 0.52-0.92). Comparing devices, benefit in terms of mortality and stroke was observed with the use of the Sentinel device (Boston Scientific), but not among other devices. No differences were observed in the outcomes of acute kidney injury, major or life-threatening bleeding events, or major vascular complications between groups. When only RCTs were included, there were no observed differences in the primary or secondary outcomes for CEP versus no CEP use during TAVR. ConclusionsThe totality of evidence suggests a net benefit for the use of CEP, weighted by studies in which the Sentinal device was used. However, given the RCT subanalysis, additional evidence is needed to identify patients at the highest risk of stroke for optimal decision-making.
引用
收藏
页数:14
相关论文
共 50 条
  • [41] Meta-analysis of the Safety and Efficacy of the Sentinel Cerebral Protection System in Transcatheter Aortic Valve Implantation
    Radwan, Yasser
    Al-abcha, Abdullah
    Salam, Mohammad Fahad
    Khor, Si Yuan
    Prasad, Rohan Madhu
    Elshafie, Ahmed
    Abela, George
    AMERICAN JOURNAL OF CARDIOLOGY, 2021, 152 : 169 - 170
  • [42] OUTCOMES WITH CEREBRAL EMBOLIC PROTECTION DEVICES DURING TRANSCATHETER AORTICVALVE REPLACEMENT: AN UPDATED META-ANALYSIS OF RANDOMIZED CONTROLLED TRIALS
    Al-Abdouh, Ahmad
    Mhanna, Mohammed
    Jabri, Ahmad
    Alhuneafat, Laith
    Zaalouk, Mostafa
    Ghanem, Fares H.
    Altibi, Ahmed
    Dewaswala, Nakeya
    Bhopalwala, Huzefa
    Barbarawi, Mahmoud
    Kundu, Amartya
    Elgendy, Islam
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2023, 81 (08) : 820 - 820
  • [43] Cerebral protection devices in transcatheter aortic valve replacement: a clinical meta-analysis of randomized controlled trials
    Wang, Nelson
    Phan, Kevin
    JOURNAL OF THORACIC DISEASE, 2018, 10 (03) : 1927 - +
  • [44] The efficacy of different types of cerebral embolic protection device during transcatheter aortic valve implantation: a meta-analysis
    Wang, Chao
    Han, Jingjun
    Lu, Liuyi
    Qiu, Junxiong
    Fu, Yuan
    Zheng, Junmeng
    FRONTIERS IN CARDIOVASCULAR MEDICINE, 2024, 11
  • [45] Cerebral Embolic Protection Devices for Prevention of Post-Procedural Ischemic Stroke With Transcatheter Aortic Valve Replacement: A Systematic Review and Meta-Analysis
    Mandava, Sri
    Ayyalu, Tanesh
    Charles, Fred
    Gade, Akhil
    Salagundla, Nethuja
    Thambidorai, Senthil
    Aragon, Joseph
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2022, 80 (12) : B132 - B132
  • [46] Cerebral protection devices for transcatheter aortic valve replacement
    Cubero-Gallego, Hector
    Pascual, Isaac
    Rozado, Jose
    Ayesta, Ana
    Hernandez-Vaquero, Daniel
    Diaz, Rocio
    Alperi, Alberto
    Avanzas, Pablo
    Moris, Cesar
    ANNALS OF TRANSLATIONAL MEDICINE, 2019, 7 (20)
  • [47] Cerebral protection devices for transcatheter aortic valve replacement
    Jobanputra, Yash
    Jones, Brandon M.
    Mohananey, Divyanshu
    Fatima, Benish
    Kandregula, Krishna
    Kapadia, Samir R.
    EXPERT REVIEW OF MEDICAL DEVICES, 2017, 14 (07) : 529 - 543
  • [48] Stroke reduction by cerebral embolic protection devices in transcatheter aortic valve implantation: a systematic review and Bayesian meta-analysis
    Heuts, Samuel
    Gabrio, Andrea
    Veenstra, Leo
    Maesen, Bart
    Kats, Suzanne
    Maessen, Jos G.
    Walton, Antony S.
    Nanayakkara, Shane
    Lansky, Alexandra J.
    van 't Hof, Arnoud W. J.
    Vriesendorp, Pieter A.
    HEART, 2024, 110 (11) : 757 - 765
  • [49] Cerebral Embolic Protection in Valve-inValve Transcatheter Aortic Valve Replacement
    Shekhar, Shashank
    Krishnaswamy, Amar
    Reed, Grant
    Puri, Rishi
    Yun, James
    Kapadia, Samir
    AMERICAN JOURNAL OF CARDIOLOGY, 2024, 216 : 110 - 111
  • [50] Editorial commentary: Use of cerebral embolic protection devices during transcatheter aortic valve replacement
    Panchal, Hemang B.
    Paul, Timir K.
    TRENDS IN CARDIOVASCULAR MEDICINE, 2018, 28 (06) : 419 - 420