Non-uniformity Correction Of Infrared Image for Wide Field With Camera Radiation Constraint

被引:0
|
作者
Xu, Feifei [1 ,2 ]
Huang, Xiaoxian [1 ,2 ]
Zhou, Ying [3 ]
Fu, Yutian [1 ,2 ]
机构
[1] Chinese Acad Sci, Shanghai Inst Tech Phys, Shanghai, Peoples R China
[2] Key Lab Infrared Syst Detect & Imaging Technol, Shanghai 200083, Peoples R China
[3] Inst Remote Sensing, Beijing 100192, Peoples R China
关键词
Infrared band; linear array camera space borne; non-uniformity correction; wide field of view high resolution; target recognition; space remote sensing; noise; push-broom image;
D O I
10.1117/12.2664751
中图分类号
V [航空、航天];
学科分类号
08 ; 0825 ;
摘要
Infrared focal plane linear array detector is the core element to achieve high spatial resolution and high radiometric resolution infrared imaging. Due to the difference of detector response rate caused by non-uniform materials and the high sensitivity of camera to background signal changes, the complex non-uniformity of the image is eventually caused. In order to identify targets effectively and quickly, real-time non-uniformity correction must be performed on infrared camera images. The most commonly used method is to obtain the correction coefficients of each pixel based on variable temperature blackbody calibration before each image. However, it is difficult and costly to design full-aperture calibration blackbody for infrared camera with wide field of view and high resolution, and the feasibility is not high. In order to correct the non-uniformity of the acquired image, this paper proposes a non-uniformity correction algorithm for single-scene infrared image based on finite constraints. According to the principle that the pixel response rate is basically unchanged, the algorithm establishes a constraint relationship between the response rate of each probe element obtained by laboratory calibration and the response rate of the central standard pixel to iteratively screen the samples involved in the correction coefficient calculation, so as to realize the non-uniformity correction of the image. The proposed algorithm was verified by using the location imaging data of the medium- wave infrared camera. The non-uniformity of local uniform image was 44.1% before correction, and decreased to 4.4% after correction, while the uniformity of conventional scene correction was 13.5% after correction. Therefore, the non-uniformity of the proposed algorithm is reduced by 9.13% compared with the conventional scene correction method. The algorithm successfully breaks through the design limitations of no star calibration device of the wide-field high-resolution infrared camera, improves the target recognition efficiency of infrared image, and is conducive to implement in engineer. In addition, it only takes about 1min to correct an image of 30000 pixel *30000 lines by testing.
引用
收藏
页数:9
相关论文
共 50 条
  • [41] On the correction for non-uniformity of field in experiments on the magnetic deflection of beta rays
    Hartree, DR
    PROCEEDINGS OF THE CAMBRIDGE PHILOSOPHICAL SOCIETY, 1923, 21 : 746 - 752
  • [42] An Efficient Technique for Non-Uniformity Correction of Infrared Video Sequences with Histogram Matching
    Mohammed Y. Abbass
    Nevein Sadic
    Huda I. Ashiba
    Emad S. Hassan
    Sami El-Dolil
    Naglaa F. Soliman
    Abeer D. Algarni
    Eatedal A. Alabdulkreem
    Fatimah Algarni
    Ghada M. El-Banby
    Mohamed R. Abdel-Rahman
    Saeed A. Aldosari
    Moawad I. Dessouky
    El-Sayed M. El-Rabaie
    Walid El-Shafai
    Ashraf A. M. Khalaf
    Ibrahim M. El-Dokany
    Fathi E. Abd El-Samie
    Journal of Electrical Engineering & Technology, 2022, 17 : 2971 - 2983
  • [43] Kalman Filter for Stripe Non-uniformity Correction in Infrared Focal Plane Arrays
    Wang, ShuPeng
    Zhang, ShiRu
    Liu, NiZhuang
    2016 INTERNATIONAL SYMPOSIUM ON COMPUTER, CONSUMER AND CONTROL (IS3C), 2016, : 124 - 127
  • [44] ADMIRE: a locally adaptive single-image, non-uniformity correction and denoising algorithm: application to uncooled IR camera
    Tendero, Y.
    Gilles, J.
    INFRARED TECHNOLOGY AND APPLICATIONS XXXVIII, PTS 1 AND 2, 2012, 8353
  • [45] New Non-uniformity Correction Approach for Infrared Focal Plane Arrays Imaging
    Qu Hui-Ming
    Gong Jing-tan
    Huang Yuan
    Chen Qian
    JOURNAL OF THE OPTICAL SOCIETY OF KOREA, 2013, 17 (02) : 213 - 218
  • [46] Scene-based non-uniformity correction: From algorithm to implementation on a smart camera
    Toczek, T.
    Hamdi, F.
    Heyrman, B.
    Dubois, J.
    Miteran, J.
    Ginhac, D.
    JOURNAL OF SYSTEMS ARCHITECTURE, 2013, 59 (10) : 833 - 846
  • [47] Dark Non-Uniformity Correction and Characterization of a 3D Flash LIDAR Camera
    Reinhardt, A. D.
    Miller, D.
    Lee, A.
    Bradley, C.
    McManamon, P. F.
    LASER RADAR TECHNOLOGY AND APPLICATIONS XXIII, 2018, 10636
  • [48] Non-uniformity correction of large area array color CCD aerial mapping camera
    Key Laboratory of Airborne Optical Imaging and Measurement, Changchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Sciences, Changchun, Jilin 130033, China
    Guangxue Xuebao, 2013, 7
  • [50] An Efficient Technique for Non-Uniformity Correction of Infrared Video Sequences with Histogram Matching
    Abbass, Mohammed Y.
    Sadic, Nevein
    Ashiba, Huda I.
    Hassan, Emad S.
    El-Dolil, Sami
    Soliman, Naglaa F.
    Algarni, Abeer D.
    Alabdulkreem, Eatedal A.
    Algarni, Fatimah
    El-Banby, Ghada M.
    Abdel-Rahman, Mohamed R.
    Aldosari, Saeed A.
    Dessouky, Moawad I.
    El-Rabaie, El-Sayed M.
    El-Shafai, Walid
    Khalaf, Ashraf A. M.
    El-Dokany, Ibrahim M.
    El-Samie, Fathi E. Abd
    JOURNAL OF ELECTRICAL ENGINEERING & TECHNOLOGY, 2022, 17 (05) : 2971 - 2983