Assessment of the Androstenedione Assay on a Roche Analytical Platform and Comparison with Different Methods

被引:0
|
作者
Ruth, Isabelle [1 ,3 ]
Le Goff, Caroline [2 ]
Peeters, Stephanie [2 ]
Bizumukama, Leonidas [1 ]
Deprez, Guillaume [1 ]
Duterme, Cecile [1 ]
Cotton, Frederic [1 ]
Wolff, Fleur [1 ]
机构
[1] Univ Libre Bruxelles ULB, Lab Hosp Univ Bruxelles LHUB ULB, Dept Clin Chem, Brussels, Belgium
[2] Unilab Lg, Dept Clin Chem, Liege, Belgium
[3] Lab Hosp Univ Bruxelles LHUB ULB, Dept Clin Chem, Rue Haute 322, B-1000 Brussels, Belgium
关键词
immunoassay; method comparison; androstenedione; mass spectrometry; radioimmunoassay;
D O I
10.7754/Clin.Lab.2022.220538
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Background: D4-androstenedione (D4ASD) is an intermediate hormone of androgen biosynthesis by the gonads and the adrenal glands. The interest in D4ASD concentration assessment resides in diagnostics of androgenic hy-perproduction pathologies. Currently, many D4ASD quantification methods are available on the market including immunological methods that remain problematic due to the possible cross-reactivity with endogenous or exoge-nous steroids.Methods: Recently Roche (R) launched a new fully automated instrument for the measurement of D4ASD concentra-tion. In this paper, the criteria of analytical performance (repeatability and intermediate precision) of the D4ASD Roche (R) assay were assessed and compared with 2 different methods including a radioimmunoassay (RIA) as well as a liquid chromatography tandem mass spectrometry (LC-MS/MS) method.Results: Repeatability and intermediate precision of the D4ASD Roche (R) were acceptable according to the prede-fined RICOS standard (CV <= 7.9%) and the assay showed a good correlation with other assays considering the 95% CI obtained for the slope and the y-intercept.Conclusions: This method demonstrates acceptable criteria of analytical performance with an intermediate impre-cision and a trueness within the fixed acceptance limits.(Clin. Lab. 2023;69:xx-xx. DOI: 10.7754/Clin.Lab.2022.220538)
引用
收藏
页码:639 / 643
页数:5
相关论文
共 50 条
  • [1] SERUM GENTAMICIN ASSAY - COMPARISON AND ASSESSMENT OF DIFFERENT METHODS
    PHILLIPS, I
    WARREN, C
    SMITH, SE
    JOURNAL OF CLINICAL PATHOLOGY, 1974, 27 (06) : 447 - 451
  • [2] Comparison of innogenetics and Roche line assay methods for human papillomavirus typing
    Sabol, I.
    Halec, G.
    Matovina, M.
    Gasperov, N. Milutin
    Grce, M.
    FEBS JOURNAL, 2006, 273 : 329 - 329
  • [3] Comparison of three serum androstenedione assays: the Siemens Immulite immunoassay, the Roche Elecsys immunoassay, and an LC-MS/MS assay
    Wei, Ruhan
    Bowers, Kathleen
    Kroner, Grace
    Payto, Drew
    Colon-Franco, Jessica
    AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 2021, 156 : S10 - S11
  • [4] THE ASSAY OF GRAVES IMMUNOGLOBULINS - A COMPARISON OF DIFFERENT METHODS
    HARDISTY, CA
    KENDALLTAYLOR, P
    ATKINSON, S
    HUMPHRIES, H
    MUNRO, DS
    CLINICAL ENDOCRINOLOGY, 1983, 18 (06) : 637 - 644
  • [5] HEPARIN ASSAY IN PLASMA - COMPARISON OF DIFFERENT METHODS
    VINAZZER, H
    ANAESTHESIST, 1979, 28 (06): : 299 - 303
  • [6] Assay of sodium in food: Comparison of different preparation methods and assay techniques
    Ploegaerts, Gregory
    Desmet, Charlotte
    Van Krieken, Michel
    JOURNAL OF FOOD COMPOSITION AND ANALYSIS, 2016, 45 : 66 - 72
  • [7] BIPHENYL LEVELS IN GRAPEFRUIT AND COMPARISON OF ASSAY BY DIFFERENT METHODS
    CHAMBON, P
    CHAMBONM.R
    ANNALES PHARMACEUTIQUES FRANCAISES, 1969, 27 (7-8): : 545 - &
  • [8] Analytical and Clinical Validation of the Roche TRAb Competitive Immunoassay and Siemens TSI Bridge Assay in the Assessment of Graves Disease
    Kemble, David
    Nerenz, Robert
    Morrison, Michael
    Jackson, Tara
    AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 2018, 149 : S190 - S190
  • [9] EVALUATION OF THE ANALYTICAL PERFORMANCE OF THE ROCHE-TDM ONLINE DIGOXIN ASSAY
    LAW, T
    BONAGURA, E
    RIFAI, N
    CLINICAL CHEMISTRY, 1995, 41 (06) : S113 - S114
  • [10] Analytical and clinical validation of the new ultrasensitive Roche Thyroglobulin II assay
    Batista, Marcelo C.
    Ferreira, Carlos E. S.
    Ferreira, Paulo R. S.
    Silva, Andre L. O.
    Faulhaber, Adriana C. L.
    Mangueira, Cristovao L. P.
    CLINICAL BIOCHEMISTRY, 2017, 50 (06) : 352 - 353