Stress and movement trend of lower incisors with different IMPA intruded by clear aligner: a three-dimensional finite element analysis

被引:13
|
作者
Li, Yixin [1 ,2 ,3 ,4 ,5 ,6 ]
Xiao, Shengzhao [1 ,2 ,3 ,4 ,5 ,6 ]
Jin, Yu [1 ,2 ,3 ,4 ,5 ,6 ]
Zhu, Cheng [1 ,2 ,3 ,4 ,5 ,6 ]
Li, Ruomei [1 ,2 ,3 ,4 ,5 ,6 ]
Zheng, Yikan [2 ,3 ,4 ,5 ,6 ,7 ]
Chen, Rongjing [1 ,2 ,3 ,4 ,5 ,6 ]
Xia, Lunguo [1 ,2 ,3 ,4 ,5 ,6 ]
Fang, Bing [1 ,2 ,3 ,4 ,5 ,6 ]
机构
[1] Shanghai Jiao Tong Univ, Shanghai Peoples Hosp 9, Sch Med, Dept Orthodont, 500 Quxi Rd, Shanghai 200011, Peoples R China
[2] Shanghai Jiao Tong Univ, Coll Stomatol, 500 Quxi Rd, Shanghai 200011, Peoples R China
[3] Natl Ctr Stomatol, 500 Quxi Rd, Shanghai 200011, Peoples R China
[4] Natl Clin Res Ctr Oral Dis, 500 Quxi Rd, Shanghai 200011, Peoples R China
[5] Shanghai Key Lab Stomatol, 500 Quxi Rd, Shanghai 200011, Peoples R China
[6] Shanghai Res Inst Stomatol, 500 Quxi Rd, Shanghai 200011, Peoples R China
[7] Shanghai Jiao Tong Univ, Shanghai Peoples Hosp 9, Sch Med, Dept Orthodont,Translat Med Res Platform Oral Biom, Shanghai 200011, Peoples R China
基金
中国国家自然科学基金;
关键词
TOOTH MOVEMENT; INVISALIGN; ATTACHMENTS;
D O I
10.1186/s40510-023-00454-7
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
BackgroundDuring the intrusion of lower incisors with clear aligners (CAs), root disengagement from the alveolar bone often occurs, resulting in serious complications. This study aimed to determine the potential force mechanism of the mandibular anterior teeth under the pressure of CA, providing theoretical data for clinical practice.MethodsIn this study, a 3D finite element model was established, including the CA, periodontal ligament, and mandibular dentition. Incisor mandibular plane angles were set as 5 groups: 90 degrees, 95 degrees, 100 degrees, 105 degrees, and 110 degrees. The 4 mandibular incisors were intruded by 0.2 mm, while the canines were the anchorage teeth. The stress, force systems, and potential movement trends of mandibular anterior teeth were obtained.ResultsThe compressive stress of the incisors was concentrated in the lingual fossa, incisal ridge, and apex. With the increase in IMPA, the moment of central incisors changed from lingual crown moment to labial crown moment, with the turning point between 100 degrees and 105 degrees, but the center of resistance (CR) was always subjected to the force toward the lingual and intrusive direction. The force and moment toward the labial side of the lateral incisors were greater than those toward the central incisors. The canines always tipped distally and received extrusive force with no relationship with IMPA.ConclusionsWith the increase in the initial IMPA, the direction of labiolingual force on the mandibular incisors was reversed. However, the root of the lower incisors always tipped labially, which indicated fenestration and dehiscence.
引用
收藏
页数:13
相关论文
共 50 条
  • [21] A three-dimensional finite element analysis for initial stress of maxillary incisors during activation of upper utility arch wire
    Lee, JH
    Cha, KS
    Lee, JW
    JOURNAL OF DENTAL RESEARCH, 2002, 81 : B322 - B322
  • [22] Three-dimensional finite element analysis of the optimal mechanical design for maximum inward movement of the anterior teeth with clear aligners
    Chen, Jingcheng
    Zhu, Daoyu
    Zhao, Mengli
    Cheng, Zhiheng
    Pan, Yan
    Liu, Xin
    SCIENTIFIC REPORTS, 2024, 14 (01):
  • [23] A three-dimensional finite element model for stress analysis of adhesive joints
    Gonçalves, J.P.M.
    De Moura, M.F.S.F.
    De Castro, P.M.S.T.
    1600, Elsevier Ltd (22):
  • [24] Stress Distribution on Bone and Implant by Three-dimensional Finite Element Analysis
    Cheng, Hsin-Chung
    Huang, Chiung-Fang
    Lin, Yi
    Shen, Yung-Kang
    JOURNAL OF THE CHINESE SOCIETY OF MECHANICAL ENGINEERS, 2014, 35 (05): : 389 - 395
  • [25] Three-dimensional finite element stress analysis of SKY implant system
    Kalanovic, M.
    Zdravkovic-Petrovic, N.
    Milosevic, M.
    Nikolic, D.
    Zdravkovic, N.
    Filipovic, N.
    Kojic, M.
    JOURNAL OF THE SERBIAN SOCIETY FOR COMPUTATIONAL MECHANICS, 2010, 4 (02) : 87 - 96
  • [26] A three-dimensional finite element model for stress analysis of adhesive joints
    Gonçalves, JPM
    de Moura, MFSF
    de Castro, PMST
    INTERNATIONAL JOURNAL OF ADHESION AND ADHESIVES, 2002, 22 (05) : 357 - 365
  • [27] Finite element analysis for the equivalent stress on three-dimensional multiasperity coating
    Xu Zhong
    Wu Xiaoyan
    MECHANIKA, 2012, (03): : 311 - 316
  • [28] Stress analysis of porcelain laminate veneer on lower central incisors with three-dimensional photoelastic experiments
    Masaru Yamanaka
    Hiroshi Kamezawa
    Shigeo Yokozuka
    Shigaku = Odontology, 1997, 85 (3): : 473 - 496
  • [29] Three-dimensional finite element analysis of the mechanical stress on root from orthodontic tooth movement by sliding mechanics
    Ping Li
    Jing Mao
    Zhou Peng
    Hui Xie
    Journal of Huazhong University of Science and Technology [Medical Sciences], 2007, 27 : 745 - 747
  • [30] Three-dimensional Finite Element Analysis of the Mechanical Stress on Root from Orthodontic Tooth Movement by Sliding Mechanics
    李平
    毛靖
    彭周
    谢晖
    Journal of Huazhong University of Science and Technology(Medical Sciences), 2007, (06) : 745 - 747