A novel method on the optimization problem of energy conservation in public buildings

被引:1
|
作者
Li, Xiaoli [1 ,2 ,3 ,5 ]
Fang, Jianhui [1 ,5 ]
Wang, Kang [1 ]
Yang, Xu [4 ]
机构
[1] Beijing Univ Technol, Fac Informat Technol, Beijing, Peoples R China
[2] Beijing Univ Technol, Beijing Key Lab Computat Intelligence & Intelligen, Beijing, Peoples R China
[3] Beijing Univ Technol, Engn Res Ctr Digital Community, Minist Educ, Beijing, Peoples R China
[4] Univ Sci & Technol, Sch Automat & Elect Engn, Beijing, Peoples R China
[5] Beijing Univ Technol, Fac Informat Technol, Beijing 100124, Peoples R China
基金
北京市自然科学基金; 中国国家自然科学基金;
关键词
Energy optimization; indoor comfortability; evolutionary algorithm; network optimization; correlation analysis; QUALITY; SYSTEM;
D O I
10.1080/15567036.2023.2193558
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
In recent years, the problem of energy consumption has received considerable attention. Among them, the proportion of energy consumption in public buildings accounts for a substantial part, and there is a large space for energy saving in this field. Practically, the major limiting factor for energy consumption optimization is indoor environment comfort degree. As such, a trade-off problem between energy conservation and indoor environment must be resolved. In this paper, an office in a public building is chosen as the experimental object, with 2520 real observations collected for two months, a series of intelligence based techniques are combined and applied to deal with this optimization problem. First, Partial Rank Correlation Coefficient (PRCC) was employed to perform correlation analysis for a set of candidate variables, such that the computational time of subsequent model training is reduced by 8.32 seconds as compared to the case where no PRCC is in use. Following this, Genetic Algorithm (GA)-based Levenberg-Marquardt algorithm (LM) are applied collectively to optimize the conventional Back Propagation (BP) neural network, and results suggest that there was a marked improvement in neural model performance, on one hand the epoch number for convergence drops from 72 to 13, on the other hand the mean squared error for test set is reduced by 7.46e-4 (from 9.93e-4 to 2.47e-4). Finally, pigeon-inspired Optimization (PIO) algorithm is employed to address the formulated optimization problem and the optimal value for Predicted Mean Vote (PMV) and Indoor Air Quality (IAQ) are -0.4775 and 0.007826, respectively. To verify the validity of our results that derived by the proposed approach, corresponding parameters are applied in a practical scenario. The experimental result indicates that the energy efficiency is improved by around 18.6% compared to that yielded before optimization is performed, which demonstrates the applicability and effectiveness of the proposed method.
引用
收藏
页码:3279 / 3296
页数:18
相关论文
共 50 条
  • [21] A new method of evaluating energy efficiency of public buildings in China
    Guo, Chunmei
    Bian, Chenhang
    Liu, Qinghua
    You, Yuwen
    Li, Shengying
    Wang, Leilei
    Journal of Building Engineering, 2022, 46
  • [22] Adaptive Optimization Method for Energy Conservation in HVAC Systems
    Nishiguchi, Junya
    Konda, Tomohiro
    Dazai, Ryota
    ASHRAE: TRANSACTIONS 2011, VOL 117, PT 1, 2011, 117 : 549 - 556
  • [23] Exploring the possibility of promoting energy conservation behaviors in public buildings within the ENCOURAGE project
    Gangolells, M.
    Casals, M.
    Fuertes, A.
    EWORK AND EBUSINESS IN ARCHITECTURE, ENGINEERING AND CONSTRUCTION, 2012, : 171 - 178
  • [24] RETROFITTING UNIVERSITY BUILDINGS FOR ENERGY CONSERVATION
    SEPSY, CF
    FULLER, RH
    ASHRAE JOURNAL-AMERICAN SOCIETY OF HEATING REFRIGERATING AND AIR-CONDITIONING ENGINEERS, 1975, 17 (08): : 45 - 46
  • [25] ENERGY-CONSERVATION IN HOSPITAL BUILDINGS
    HYMAN, WA
    BUILDING SYSTEMS DESIGN, 1979, 76 (06): : 41 - 47
  • [26] ENERGY-CONSERVATION OF BUILDINGS IN TAIWAN
    YANG, KH
    HWANG, RL
    PATTERN RECOGNITION, 1995, 28 (10) : 1483 - 1491
  • [27] ECONOMICS OF ENERGY-CONSERVATION IN BUILDINGS
    FISK, D
    RIBA JOURNAL-ROYAL INSTITUTE OF BRITISH ARCHITECTS, 1979, 86 (10): : 445 - 446
  • [28] A Survey of Energy Conservation in Smart Buildings
    Sun, Jie
    Zhang, Yong-Ping
    INTERNATIONAL CONFERENCE ON ENERGY AND ENVIRONMENT ENGINEERING (ICEEE 2015), 2015, : 58 - 62
  • [29] Potential for energy conservation in apartment buildings
    Balaras, CA
    Droutsa, K
    Argiriou, AA
    Asimakopoulos, DN
    ENERGY AND BUILDINGS, 2000, 31 (02) : 143 - 154
  • [30] Energy Conservation Practices in Universities Buildings
    Hasim, Mohamed Sufian
    Azam, Wan Farissa Haslin Wan
    Hashim, Ahmad Ezanee
    Ariff, Nor Rima Muhamad
    ENVIRONMENT-BEHAVIOUR PROCEEDINGS JOURNAL, 2019, 4 (12): : 123 - 130