Ultra-short columns for the chromatographic analysis of large molecules

被引:10
|
作者
Fekete, Szabolcs [1 ]
Guillarme, Davy [2 ,3 ]
机构
[1] Waters Corp, Geneva, Switzerland
[2] Univ Geneva, Inst Pharmaceut Sci Western Switzerland, CMU Rue Michel Servet 1, CH-1211 Geneva 4, Switzerland
[3] Univ Geneva, Sch Pharmaceut Sci, CMU Rue Michel Servet 1, CH-1211 Geneva 4, Switzerland
关键词
Ultra-short columns; Biopharmaceuticals; Fast analysis; Monoclonal antibodies; PERFORMANCE LIQUID-CHROMATOGRAPHY; GRADIENT ELUTION; MEMBRANE CHROMATOGRAPHY; MONOCLONAL-ANTIBODIES; PROTEIN SEPARATIONS; SIZE-EXCLUSION; RESOLUTION; OPTIMIZATION; MODEL;
D O I
10.1016/j.chroma.2023.464285
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Today, reverse phase liquid chromatography (RPLC) analysis of proteins is almost exclusively performed on conventional columns (100-150 mm) in gradient elution mode. However, it was shown many years ago that large molecules present an on/off retention mechanism, and that only a very short inlet segment of the chromatographic column retains effectively the large molecules. Much shorter columns -like only a few centimetres or even a few millimetres -can therefore be used to efficiently analyse such macromolecules.The aim of this review is to summarise the historical and more recent works related to the use of very short columns for the analysis of model and therapeutic proteins. To this end, we have outlined the theoretical concepts behind the use of short columns, as well as the instrumental limitations and potential applications.Finally, we have shown that these very short columns were also possibly interesting for other chromatographic modes, such as ion exchange chromatography (IEX), hydrophilic interaction chromatography (HILIC) or hydrophobic interaction chromatography (HIC), as analyses in these chromatographic modes are performed in gradient elution mode.
引用
收藏
页数:14
相关论文
共 50 条
  • [21] Widely Tunable Large Area SBRs for Ultra-short Pulse Generation
    Nabanja, S.
    Sander, M. Y.
    Morse, J.
    Shtyrkova, K.
    Petrich, G. S.
    Kolodziejski, L. A.
    Kaertner, F. X.
    Ippen, E. P.
    2012 CONFERENCE ON LASERS AND ELECTRO-OPTICS (CLEO), 2012,
  • [22] Ultra-short PROMs: clever or not?
    Zimmermann, C.
    BRITISH JOURNAL OF CANCER, 2010, 103 (10) : 1477 - 1478
  • [23] DAILY ULTRA-SHORT HEMODIALYSIS
    NARET, C
    DELONS, S
    MAN, NK
    NEPHROLOGIE, 1991, 12 (04): : 209 - 209
  • [24] Ultra-short wave propagation
    Schelleng, JC
    Burrows, CR
    Ferrell, EB
    BELL SYSTEM TECHNICAL JOURNAL, 1933, 12 : 125 - 161
  • [25] Extending ultra-short pulse laser texturing over large area
    Mincuzzi, G.
    Gemini, L.
    Faucon, M.
    Kling, R.
    APPLIED SURFACE SCIENCE, 2016, 386 : 65 - 71
  • [26] Analysis of electromagnetic systems irradiated by ultra-short ultra-wideband pulse
    Sarkar, TK
    Koh, JW
    Lee, W
    Palma, MS
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2001, 12 (11) : 1757 - 1768
  • [27] Novel applications of short and ultra-short pulses
    Strassl, M
    Kopecek, H
    Weinrotter, A
    Bäcker, A
    Al-Janabi, AH
    Wieger, V
    Wintner, E
    APPLIED SURFACE SCIENCE, 2005, 247 (1-4) : 561 - 570
  • [28] The application of ultra-short light pulses for the analysis of quickly relaxing organic molecules by means of laser mass spectrometry
    Grun, C
    Heinicke, R
    Weickhardt, C
    Grotemeyer, J
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 1999, 185 : 307 - 318
  • [29] Analysis of ultra-short bunches in free-electron lasers
    Campbell, L. T.
    Freund, H. P.
    Henderson, J. R.
    McNeil, B. W. J.
    Traczykowski, P.
    van der Slot, P. J. M.
    NEW JOURNAL OF PHYSICS, 2020, 22 (07):
  • [30] Analysis of Laser Ablation of CFRP by Ultra-Short Laser Pulses with Short Wavelength
    Emmelmann, C.
    Petersen, M.
    Goeke, A.
    Canisius, M.
    LASERS IN MANUFACTURING 2011: PROCEEDINGS OF THE SIXTH INTERNATIONAL WLT CONFERENCE ON LASERS IN MANUFACTURING, VOL 12, PT A, 2011, 12 : 565 - 571