Establishment and Validation of an Integrated Microfluidic Step Emulsification Chip Supporting Droplet Digital Nucleic Acid Analysis

被引:3
|
作者
Luo, Gangyin [1 ,2 ]
Zhang, Ying [3 ]
Wang, Shun [1 ]
Lv, Xinbei [4 ]
Yang, Tianhang [1 ]
Wang, Jinxian [1 ,2 ]
机构
[1] Chinese Acad Sci, Suzhou Inst Biomed Engn & Technol, Suzhou 215163, Peoples R China
[2] Univ Sci & Technol China, Sch Biomed Engn Suzhou, Div Life Sci & Med, Hefei 230026, Peoples R China
[3] JiHua Lab, Foshan 528251, Peoples R China
[4] Harbin Engn Univ, Qingdao Innovat & Dev Base, Qingdao 266000, Peoples R China
来源
BIOSENSORS-BASEL | 2023年 / 13卷 / 09期
基金
中国博士后科学基金;
关键词
step emulsification; micro-droplet; integrated microfluidic chip; nucleic acid detection; NUMBER; PCR;
D O I
10.3390/bios13090888
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Uniform and stable droplet generation is critical for accurate and efficient digital nucleic acid analysis (dNAA). In this study, an integrated microfluidic step emulsification device with wide-range droplet generation capability, small device dimensions, convenient fabrication strategy, low contamination and high robustness was developed. A tree-shaped droplet generation nozzle distribution design was proposed to increase the uniformity of droplet generation by equating flow rates, and the flow field in the design was numerically simulated. Theoretical analysis and comparative experiments on droplet size were performed regarding the influences of nozzle dimensions and surface properties. With incubation and hydrophobic reagent treatment, droplets as small as 73.1 mu m were generated with multiplex nozzles of 18 mu m (h) x 80 mu m (w). The droplets were then collected into a standard PCR tube and an on-chip monolayer droplet collection chamber, without manual transfer and sample contamination. The oil-to-sample volume ratio in the PCR tube was recorded during collection. In the end, the droplets generated and collected using the microfluidic device proved to be stable and uniform for nucleic acid amplification and detection. This study provides reliable characteristic information for the design and fabrication of a micro-droplet generation device, and represents a promising approach for the realization of a three-in-one dNAA device under a step emulsification method.
引用
收藏
页数:12
相关论文
共 50 条
  • [21] Droplet Microfluidic Chip Based Nucleic Acid Amplification and Real-Time Detection of Influenza Viruses
    Prakash, R.
    Pabbaraju, K.
    Wong, S.
    Wong, A.
    Tellier, R.
    Kaler, K. V. I. S.
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2014, 161 (02) : B3083 - B3093
  • [22] Integrated nucleic acid purification technology based on amino-modified centrifugal microfluidic chip
    Dong, Yongkang
    Chen, Bailiang
    Cai, Gangpei
    Xu, Fei
    Li, Linzhi
    Cheng, Xiaoqi
    Shi, Xiaolu
    Peng, Bo
    Mi, Shengli
    BIOTECHNOLOGY JOURNAL, 2024, 19 (02)
  • [23] DIGITAL MICROFLUIDIC CHIP BASED ON DIRECT INK WRITING FOR NUCLEIC ACID MULTIPLEX PCR DETECTION
    Shen, Chuanjie
    Yin, Hao
    Tong, Zhaoduo
    Qiu, Shihui
    Lu, Yunxing
    Wu, Zhenhua
    Mao, Hongju
    2022 IEEE 35TH INTERNATIONAL CONFERENCE ON MICRO ELECTRO MECHANICAL SYSTEMS CONFERENCE (MEMS), 2022, : 365 - 368
  • [24] Integrated Full-Range Droplet Actuation for Inkjet-Printed Digital Microfluidic Chip on Flexible Substrates
    Wang, He
    Chen, Liguo
    IEEE TRANSACTIONS ON NANOBIOSCIENCE, 2022, 21 (01) : 10 - 20
  • [25] A digitalized isothermal nucleic acid testing platform based on a pump-free open droplet array microfluidic chip
    Mao, Ping
    Cao, Lei
    Li, Zedong
    You, Minli
    Gao, Bin
    Xie, Xianghong
    Xue, Zhenrui
    Peng, Ping
    Yao, Chunyan
    Xu, Feng
    ANALYST, 2021, 146 (22) : 6960 - 6969
  • [26] Integrated Droplet-Based Digital Loop-Mediated Isothermal Amplification Microfluidic Chip with Droplet Generation, Incubation, and Continuous Fluorescence Detection
    Lin, Yen-Heng
    Hung, Yuan-Ting
    Chang, Wei
    Chiou, Chiuan-Chian
    BIOSENSORS-BASEL, 2024, 14 (07):
  • [27] Simulation analysis and experimental verification of thermodynamic characteristics of integrated droplet digital PCR chip
    Meng, Xiangkai
    Duanmu, Luyang
    Gong, Ping
    MICROFLUIDICS AND NANOFLUIDICS, 2024, 28 (07)
  • [28] Ultrasensitive quantification of tumor mRNAs in extracellular vesicles with an integrated microfluidic digital analysis chip
    Zhang, Peng
    Crow, Jennifer
    Lella, Divya
    Zhou, Xin
    Samuel, Glenson
    Godwin, Andrew K.
    Zeng, Yong
    LAB ON A CHIP, 2018, 18 (24) : 3790 - 3801
  • [29] An integrated droplet microfluidic chip for digital polymerase chain reaction with a fountain-like structure capable of removing bubble
    Jiang, Keming
    Zhang, Tao
    Liu, Cong
    Zhang, Zhiqiang
    Li, Haiwen
    SENSORS AND ACTUATORS B-CHEMICAL, 2025, 433
  • [30] A rapid multiplex nucleic acid detection system of airborne fungi by an integrated DNA release device and microfluidic chip
    Lu, Huijun
    Zhu, Jinhui
    Zhang, Tong
    Zhang, Xinlian
    Chen, Xi
    Zhao, Wei
    Yao, YuHan
    Zhao, Wang
    Sui, Guodong
    TALANTA, 2022, 246